The standard Easibath has a mains electrical connection to power the lifting mechanism and whirlpool 
system (if fitted). There is a risk of electrocution if any wires become damaged and a potential fire risk 
if  the  mechanisms  fail  and  overheat.  Your  bath  should  only  be  used  if  any  powered  equipment  on  it 
(eg. Whirlpool, raise/lower system etc.) is connected to a suitable power supply protected by an earth 
leakage  circuit  breaker.  The  electrical  requirements  are  contained  in  the  pre-installation  instructions 
available  from  Kingkraft.  Test  the  earth  leakage  circuit  breaker  which  supplies  power  to  your  bath 
regularly  (at  least  once  a  week),  and  if  you  are  in  any  doubt  about  its  operation,  consult  a  qualified 
electrician before using the bath.  

 

 
 
 
 
 
 
 

       

       WARNING 

 
 
 
If thermostatic mixer valves are fitted, please refer immediately to the manufacturer if the water is too 
cold or too hot and do not use the bath until the problem is corrected.  
 
If conventional hot and cold taps are fitted, please ensure that the bath water is fully mixed by hand (if 
cool  enough)  or  mixer  paddle  to  a  safe  temperature,  prior  to  using  the  bath.  WARNING!  With  no 
thermostatic valve attached there is the danger of scalding! 
 
Certain  bath  additives  may  damage  the  bath,  if  they  contain  bleach  or  other  corrosives.  Use  only 
water,  normal  soaps  and  approved  cleaning  agents.  If  in  doubt,  please  contact  Kingkraft  for  advice 
about the suitability of the additives you wish to use. Kingkraft recommend Chemgene. 
 
Under  no  circumstances  must  acid  or  bleach  based  cleaners  be  used.  To  do  so  invalidates  your 
guarantee.  We  recommend  that  your  Kingkraft  Bath  should  be  cleaned  with  Chemgene  which  is 
available from us. See the section on cleaning below for instructions on how to safely clean your unit.  
 
If  your  unit  has  any  electrical  controls,  switch  off  the  supply  at  the  wall  isolator  (mains  units)  or 
disconnect  and  remove  the  battery  pack  (battery  units  only)  before  attempting  any  maintenance, 
including cleaning.  
 
Do  not  use  pressurised  water  jets  to  clean  the  bath  and  keep  water  jets  away  from  the  controls, 
pumps and the bath chassis when cleaning around the bath. Do not steam clean. 
 
If  your  Easibath  is  fitted  with  a  whirlpool  hydrotherapy  system,  use  only  low  foaming  bath  additives. 
Normal  bubble  baths  will  froth  excessively  with  whirlpools  and  must  not  be  used  as  they  pose  a 
serious risk of drowning / suffocation / asphyxiation to the user and many cause damage to property. 
 
Do not attempt maintenance unless the bath is empty. 
 
Check the Easibath frequently for damage, especially the mains lead and earth wire. If you find signs 
of damage, do not use the bath and contact Kingkraft as soon as possible to arrange for service and 
repair.  

 

RISK OF SCALDING

 

 
Although safety devices can be fitted as an option to minimise any 
risk  of  scalding,  users  must  be  aware  that  these  are  not 
necessarily  fail  safe.  The  temperature  of  the  water  in  the  bath 
MUST BE INDEPENDENTLY VERIFIED ON EVERY OCASION it 
is  used  and  before  an  incapacitated  person  comes  into  contact 
with  the  water.  Ideally  a  calibrated  thermometer  should  be  used. 
Please  check  if  your  bath  specification  includes  for  these  mixer 
valves. 

 

Содержание EASIBATH

Страница 1: ...Please read these instructions carefully before first using your Kingkraft product and then keep them safely for future reference Please also make sure that each person and any carer who uses the bat...

Страница 2: ...he Bath Opening Closing Bath Side Bath Mattress Options Tap Control and Shower Options To fill the bath Optional Shower Unit Cleaning Your Bath Mains Powered Easibath BASIC ELECTRICAL CIRCUITS ON BATH...

Страница 3: ...g surface The Easibath is not intended for the dependent Bather to be left unattended in the Bath The standard Easibath is available in a choice of three standard models of 1700 1900 and 2100 There is...

Страница 4: ...uire that in general no person should lift a mass of greater than 25kg unaided Use appropriate lifting equipment if this is required to help disabled people to get in and out of the bath Your bath mus...

Страница 5: ...nder no circumstances must acid or bleach based cleaners be used To do so invalidates your guarantee We recommend that your Kingkraft Bath should be cleaned with Chemgene which is available from us Se...

Страница 6: ...t of the bath if there is a fault power failure when the bath is in its highest position The variable height adjustment if specified allows the bath to be raised to working heights suitable for most c...

Страница 7: ...ons are made from PVC Please make sure the user will not have any allergic reactions to this material before use Some supports are attached to the base of the bath by suckers In all cases these sucker...

Страница 8: ...eration then there is likely to be a fault and the bath raise lower function should not be used further until an engineer has checked the installation and rectified any fault To lower bath side door T...

Страница 9: ...op up waste s open to allow any cold water to flow away This process should be continued until the water temperature is perceived to be constant This operation will allow the mixed water temperature t...

Страница 10: ...ower Options Hot and Cold taps Reliance Caremix H3 Thermastatic Mixer tap Rada Autotherm 3 Thermastatic Mixer tap Shower Rada Sense System Bath Fill only Rada Sense System Bath Fill and Shower CAT 3 S...

Страница 11: ...Board Valves simply open the tap on the bath to start the flow If the bath has conventional hot and cold taps simply turn them both on as required to get the desired mixed temperature REMEMBER THE TE...

Страница 12: ...The handset must not be submerged or subjected to pressurised water cleaning If the bath is a static fixed height version there will be no active lifting system but a mains cable current may still be...

Страница 13: ...To recharge the battery simply unclip it and attach it to the wall mounted battery charger well away from the wet area and free from interference A light will illuminate when the battery is charging...

Страница 14: ...ged by Kingkraft Engineers or qualified electricians and replaced with the correct specified fuse Do not immerse the power cord in water or run over it trap it with mobile devices Lifting Mechanism Wh...

Страница 15: ...ext to the head end of the bath tub To vary the amount of turbulence in the bath turn the control button on the bath either clockwise to increase or anti clockwise to decrease the turbulence To adjust...

Страница 16: ...ry use Chemgene Trigene is used in the diluted form for general disinfection of the bath surfaces only As an alternative Chemgene Trigene in its concentrated form it can be used for disinfection of th...

Страница 17: ...n a bathroom type location where exposed mains connections and unsealed switches etc are not permitted The unit must not be connected via a plug and socket The power supply to the Easibath if powered...

Страница 18: ...lower buttons on the handset membrane switch and you can hear a beeping sound coming from the bath you will have to follow this initialisation sequence to re set the bath Failure of the mains power to...

Страница 19: ...fill the bath so the water flow is at maximum and record the temperature of the water flowing into the bath 1 3 Set the bath fill control so that the flow of water into the bath is at a minimum and th...

Страница 20: ...or damage 9 Check operation of RCD 10 Check all other wires and electrical enclosures for damage 11 Check pipes etc for leaks 12 Check all knobs and handles securely attached 13 Check all controls eas...

Страница 21: ...old water isolation valves 6 Hot water supply pressure 7 Cold water supply pressure 8 Hot water supply temperature 9 Cold water supply temperature 10 Outlet temperature at maximum flow 11 Maximum outl...

Страница 22: ...The following are examples of markings found on the Easibath Bath identity label Sample Power Actuator Labels These may vary according to the specification of the bath Bath fill control Shower control...

Страница 23: ...ithout notice WEEE Waste Electrical and Electronic Equipment Regulations 2006 The aim of this Directive is to minimise the impact of electrical and electronic equipment on the environment when product...

Отзывы: