background image

HHO CARBON CLEANER 6.0 OPERATION MANUAL

11

5

off

machine stop working

6

on

machine start working

7

set

start time setting

8

set

enter the time setting state

9

check

check accumulated working times

10

start

start producing gas

Over pressure indicator

: Once the pressure reaches 0.2mpa, the light on, machine

will stop producing gas. during carbon cleaning process, the light is not bright.

Over heat indicator

: when the electrolytic temperature is higher than set

temperature, the light on, machine will stop producing gas. The light is not bright

under normal conditions, unless the fan is not working or poor cooling.

Adding Water Indicator

: When the water level of water tank is low, Adding Water Indicator

will on. At this time, you need to open the cover at the top of machine, add water to the water

tank through the filling opening. Adding until the indicator light off, should stop adding water.

If Adding Water Indicator light turns on, but without timely adding water, it will cause to lack

of water and the machine will automatically shut down.

Set

: It is to set the time of carbon cleaning, the time setting is according to the time of

cleaning, normally 20 minutes.

Set

: We assume the the four-digit timer display is shown as:AB:CD, first press the setting

button to enter setting mode. it displays D, you can press the timing button continuously the

digit D circularly ranges from 0 to 9. if you want to set the C digit,and then press the settings

button, the operation of setting A or B is the same. Under normal circumstances, set the

timer at 20:00 minutes.

Pressure gauge:

it is used for displaying the internal abnormal pressure value of carbon

cleaning machine supply system. Since catalyzed oxyhydrogen gas is vacuum inhaled into

the car engine, so the gauge keep the normal value; when excessive gas is gathered in the

machine, or external gas is blocked, the gauge pointer will rise when the pressure reaches

0.2Mpa. At then the machine will be in the state of protection, it will stop producing gas.When

the internal gas fully leak out, the machine automatically resume gas production

Note:

As the car model is FAW-Volkswagen Bora or Buick Excelle two models, if the machine

appears shut down constantly, because the vacuum tube is smaller than other car, it should

set the gas production as 700-800L/h; the machine can do carbon cleaning normal later.

If do carbon cleaning for diesel car, please connect with air filter, and use provided connector.

Содержание HHO

Страница 1: ...ollow its instruction For your safety please assemble maintain check and repair the equipment by the professionals For your safety please pay much attention to the safety instructions in the manual an...

Страница 2: ...t is forbidden to enter the cab for vehicle operation especially step on accelerate 4 In the process of carbon cleaning processing the other engine maintenance items is prohibited 5 In the process of...

Страница 3: ...6 The working process of carbon cleaning 13 7 Fault analysis and elimination 15 8 Notice 17 9 Maintenance of the Machine 17 Annex I The work flow chart of HHO Carbon Cleaning Machine 18 Annex II Notic...

Страница 4: ...n cleaner agent into the engine combustion chamber through the engine idling to remove carbon deposits inside the engine restore the original engine performance improve throttle response speed and red...

Страница 5: ...ion 3 We recommend placing this machine in open space with good ventilation 4 The distance between the car and machine should be less than 10 meters it is better control in 5 meters 2 2 Add carbon cle...

Страница 6: ...e 7 cleaner agent and negative pressure detection input 8 water level probe and anti backfire probe detection input 9 indicator light interface 10 power protection solenoid valve 11 AC contactor inter...

Страница 7: ...HHO CARBON CLEANER 6 0 OPERATION MANUAL 7 3 The introduction of machine structure 3 1 Outside structure Pic 3 Front Pic 4 Back...

Страница 8: ...HHO CARBON CLEANER 6 0 OPERATION MANUAL 8 Pic 5 Control panel Pic 6 Circuit Control System Module 3 2 Inside structure Pic 7 Left side...

Страница 9: ...HHO CARBON CLEANER 6 0 OPERATION MANUAL 9 Pic 8 right side Pic 9 top side...

Страница 10: ...therwise the light will not be bright B1 over water indicator the light on when solenoid valve broken and stop draining off water B2 add water indicator the light on when water lower than lowest set l...

Страница 11: ...the time of cleaning normally 20 minutes Set We assume the the four digit timer display is shown as AB CD first press the setting button to enter setting mode it displays D you can press the timing bu...

Страница 12: ...the power line are connected solid and reliable before start any power supply 4 7 We suggest place the machine in a fixed location forbid to move the machine during carbon cleaning 4 8 Before start th...

Страница 13: ...car in stationary state have flamed out Automobile cluch in park sated and hand brake state these will avoid car slide accidental Once again confirm the automotive fuel is enough for car running for...

Страница 14: ...the Start button in the front panel of HHO Carbon Cleaner 6 0 It will start working the countdown time begin at the same time machine will receive work instruction Pic 13 6 10 Adjust Gas Output until...

Страница 15: ...0 the system will automatically cut off electrolytic power stop to produce oxy hydrogen gas 6 14 Continue to wait for 1 minute so that complete the transportation of the rest oxy hydrogen gas 6 15 Let...

Страница 16: ...water tank or pipe joint or pressure gauge is damaged Replace gas out pipe tighten the interface replace sealing element and pressure relief valve of main water tank replace pressure gauge 5 Appear fl...

Страница 17: ...ne using the compressed air machine once a month Replacing the electrolyte and cleaning the electrolytic cell for twelve month 9 Maintenance of the Machine The Introduction of Electrolytic Cell s Clea...

Страница 18: ...Start the on button 7 Start the start button 8 Adjust gas output 9 Adjust the valve to control the speed of cleaner agent flow 10 Waiting the countdown time to 00 00 12 Let the car continue to run 1 m...

Страница 19: ...r to water tank of the machine immediately During carbon cleaning process if appear engine flameout don t re start the engine please deal with according to operation introduction in Annex3 Details as...

Страница 20: ...e from car s vacuum tube C Blowing the engine and air intake tube by using compressed gas keep 3 minutes discharge all the remaining Oxy hydrogen gas and then keep rest for 5 minutes Note Before finis...

Страница 21: ...tion hydrometer KOH concentration 95 Purified water 1 bottle table vinegar 1pair rubber gloves Other protective articles 2 Make make up the electrolyte add it electrolyte for the machine Model KOH Pur...

Страница 22: ...wear safety goggles and silicone glove when conduct this step You should prepared these one big stainless steel funnel one stainless steel spoon one stainless steel kettle a pair of silicone gloves a...

Страница 23: ...solution when add electrolyte Stop adding electrolyte when there is only 10cm from the water level to the filling opening 4 Return the water level sensor fix and seal it Reconnect the water level sen...

Страница 24: ...ity maintenance since sold out After one year only charge raw material fees Physical damage is not within the scope of warranty Without our written authorization any organization or individual does no...