QUICK REFERENCE GUIDE: KI7600C Series Optical Power Meter
KI7000 UM-5
-
54 -
MANUAL OPERATION
•
To remove interchangeable connector adaptor, press button
on rear of case and pull off adaptor. This may be easier with
a test lead attached.
•
To defeat auto power-off
,
hold [POWER] for 3 seconds at turn
on until ‘ON’ and ‘Perm’ are displayed
•
Low battery is indicated with a battery symbol
•
To select operational wavelength, press [Power Meter] [-/+]
•
To set reference, press [ABS/REL] and hold [SET REF] for 3
seconds. Meter displays about 0.00 dB R
•
To stop / start display update, press [HOLD]
•
If a test tone is detected, meter will display ‘Hz’
•
To toggle log / linear display mode, press [dB/W]
•
To display minimum and maximum recorded power for
selected wavelength, press [
] and [Max/Min]. Press [
]
[Max/Min] and hold for 3 seconds to re-start recording.
AUTOTEST OPERATION
•
To initiate Autotest, connect Power Meter to Light Source and
press [Autotest] on Light Source.
•
To show one wavelength only, scroll [-/+]. Press [Menu] to
exit.
•
Autotest remains for 8 seconds after signal loss, to allow
quick connection change
•
To exit Autotest, remove test lead for >8 seconds, or on the
Light Source, press [MENU]
MEMORY OPERATION
•
Data can be stored in Power Meter and Autotest modes,
however, memory recall and cancel functions are not
available in Autotest.
•
To clear all memory,
press both [MR] and [Exit]
simultaneously for 3 seconds. ‘clr’ will display.
•
To store in next default location, press [M+].
•
To change next store location, press [
◄►
] [-/+] [Set]
•
or [Menu].
•
To recall, press [MR] and [-/+] to scroll memory.
•
Exit Autotest and enter Power Meter mode to read or cancel
memory.
•
Autotest memory recall: use [-/+] to scroll wavelengths.
•
To exit memory display, press [Menu].
VISIBLE LASER OPTION
•
Select [POWER], [SOURCE]
•
To stop modulation, press [MOD]. To change modulation
frequency, press [
] and [KHz] on the hidden keypad. Use
[+/-] to scroll modulation frequencies, then press [Set] to
store.
•
To turn off laser, press [-/+].
Содержание KI7300 Series
Страница 1: ......
Страница 57: ...QUICK REFERENCE GUIDE KI7600C Series Optical Power Meter KI7000 UM 5 55 ...
Страница 59: ...QUICK REFERENCE GUIDE KI7400C 7800C Series Optical Light Source KI7000 UM 5 57 ...
Страница 62: ...QUICK REFERENCE GUIDE KI7300C 7700C Series Loss Test Set KI7000 UM 5 60 ...
Страница 64: ...NOTES KI7000 UM 5 62 ...
Страница 65: ...NOTES KI7000 UM 5 63 ...
Страница 66: ...NOTES KI7000 UM 5 64 ...