20
Fitting in column
FO 0290
Only qualified personnel should
install the appliance (place in cabinet
and make electrical connection).
Every operation must be carried out
with appliance disconnected from
the electricity supply; when this is not
possible the maximum care is
required when working on the
appliance.
Fixing the oven into kitchen cabinets
Any cabinet containing an electrical appliance
must have the charcteristics held suitable for
this purpose to permit the appliance to operate
to its best potential.
Protection against any possible contact with
the electrical parts must be assured through the
correct installation of the appliance into the
cabinet, in accordance with the current safety
regulations. All parts which assure protection,
even a cover panel (where for example the
appliance is positioned at the beginning or at the
end of the cabinet composition) must be fixed in
such a way that they cannot be removed without
the aid of tools.
Dimensions of the oven
FO 0208
Building in
Instructions for the installer
Technical Data
Recess dimensions:
Height
in coloumn
cm 59,1
undertop
cm 58,0
Width
cm 55,0
Depth
cm 56.0
Internal oven dimensions:
Height
cm 32,5
Width
cm 42,0
Depth
cm 39,0
Volume
dm
3
53
Oven elements
Bottom heating element
1000 W
Top heating element
800 W
Full Oven (Top+Bottom)
1800 W
Grill heating elements simple 1750 W
double 2550 W
Fan Oven heating element
2000 W
Oven lamp
25 W
Convection fan
30 W
Cooling fan
20 W
Maximum power rating
2600 W
Voltage tension (50 Hz)
230 V