background image

5

Minimum Clearance To Combustible Walls

D

E

D

E

A

F

B

G

C

D

E

D

E

A

F

B

G

C

D

E

D

E

A

F

B

G

C

Minimum clearances for corner 

installation is 12 inches (305mm) from the 

corners of the heater to the nearest wall.

The provision that clearances may only 

be reduced by means approved by 

regulatory authority

CAUTION: 

Keep furnishings and other 

combustible materials away from the 

heater.

Stove Clearances

A   Side Wall

18" (457mm)

B Back Wall

12" (305mm)

C

Ceiling Height

84" (2134mm)

D

Closest Wall to Corner 

12" (305mm)

E Wall to Chimney Connector (Alcove)

21" (533.4mm)

F Side Wall to Chimney Connector 

22.25" (565mm)

G Back Wall to Chimney Connector

15" (381mm)

Содержание 2016E

Страница 1: ...Before Starting The Installation or Operating This Heater Improper Installation Could Void Your Warranty Please read this entire manual before you install and use your new room heater Failure to follo...

Страница 2: ...STM E2780 10 single Burn Rate Appendix and an efficiency of 66 6 This wood heater has a manufacturer set minimum low burn rate that must not be altered It is against federal regulations to alter this...

Страница 3: ...ercial garbage Lawn clippings or yard waste Materials containing rubber including tires Materials containing plastic Waste petroleum products paints or paint thinners or asphalt products Materials con...

Страница 4: ...e this heater who is unfamiliar with the correct operation of the heater 12 For additional information on using your Room Heater safely obtain a copy of the National Fire Protection Association NFPA p...

Страница 5: ...vision that clearances may only be reduced by means approved by regulatory authority CAUTION Keep furnishings and other combustible materials away from the heater Stove Clearances A Side Wall 18 457mm...

Страница 6: ...ns Check Figures 2 3 4 You should have at least the clearances shown from the heater and the connector pipe to combustible surfaces If you have a solid brick or stone wall behind your heater you can p...

Страница 7: ...Heat Shield 891861 1 8 10AB x 3 8 Hex Screw 83172 12 N S 12 x 3 4 Teks Screw C23799 4 ASSEMBLY INSTRUCTIONS Step 1 THE BLOWER ASSEMBLY MUST BE DISCONNECTED FROM THE SOURCE OF ELECTRICAL SUPPLY BEFORE...

Страница 8: ...Chimneys perform two functions one of which is apparent The chimney provides a means for exhausting smoke and flue gases resulting from combustion of the fuel Secondarily though the chimney provides D...

Страница 9: ...lti layered construction It is designed to provide enough insulation and or air cooling so that the base back and sides can be safely placed in direct contact with combustible floors and walls Althoug...

Страница 10: ...flue outlet requires a 6 152mm diameter for optimum drafting but can function well with an 8 203mm but becomes borderline beyond an 8 203mm diameter Masonry chimneys built of concrete blocks with or...

Страница 11: ...fireclay at least 5 8 inch thick or metal thimble being sure that the thimble is flush with the inner flue lining secure the thimble in place with refractory mortar The thimble should be surrounded on...

Страница 12: ...himney connector and a minimum 24 gage ventilated wall thimble which has two air channels of 1 25 4 mm each construct a wall pass through There shall be a minimum 6 152 4 mm separation area containing...

Страница 13: ...The pipe cannot extend into the chimney flue Fig 8 5 Seal each connector pipe joint with furnace cement Also seal the pipe at the chimney 6 Use 3 sheet metal screws at each joint to make the piping ri...

Страница 14: ...ocess as a vapor in the case of wood stoves the moisture in the wood being burned leaves the stove as a vapor The higher heating value is when water leaves the combustion process completely condensed...

Страница 15: ...Do not expect a heater to draw It is the chimney that creates the draft Smoke spillage into the house or excessive buildup of water or creosote in the chimney are warnings that the chimney is not func...

Страница 16: ...connector and chimney should be inspected at least once every two months during the heating season to determine if a creosote buildup has occurred If creosote has accumulated it should be removed to...

Страница 17: ...ust be replaced using original manufacturers parts purchased through your dealer or directly from the appliance manufacturer Use of third party components will void the warranty 1 2 3 4 6 5 7 Key Part...

Страница 18: ...irebrick Half 4 1 2 X 4 1 2 2 4 86645 Tube 7 32 Secondary Air 1 5 88250 Board Ceramic Fiber 2 In order to maintain warranty components must be replaced using original manufacturers parts purchased thr...

Страница 19: ...r assembly must be disconnected from the source of electrical supply before attempting any maintenance Brick Placement Top Inside View Of Firebox 1 Insert right left side firebrick as shown 2 Insert r...

Страница 20: ...tube and remove to allow the tube to be removed and replaced Whenever ashes get 3 to 4 inches deep in your firebox or ash pan and when the fire has burned down and cooled remove excess ashes Leave an...

Страница 21: ...IONS 1 United States Stove Company shall not be liable for incidental consequential special or contingent damages anyone might suffer as a result of their breach of this written warranty or any implie...

Страница 22: ...to the heater When ordering repair parts always give the following information as shown in this list 1 The part number _____________________________________ 2 The part description ___________________...

Страница 23: ...___ Reason for Purchase qAlternative Heat qMain Heat Source qDecoration qCost qOther _________________________ What was the determining factor for purchasing your new appliance _______ I have read the...

Страница 24: ...CUT HERE CUT HERE Fold Here Fold Here United States Stove Company P O Box 151 South Pittsburg TN 37380 Fold Here PLACE STAMP HERE...

Отзывы: