7
This heater comes equipped with a
cast-iron flue collar.
Flue Collar - 40292
5/16-18 x 1-1/2" Bolts (3 req.)
Weld Tab (3 req.)
Gasket
Mounting Cast-Iron Flue Collar
KEY DESCRIPTION
PART NO. QTY.
1
Blower Housing Back
25089B
1
2
Blower Housing Front
25090B
1
3
Blower Motor
80442
1
4
Rheostat w/Nut and Knob 80090
1
5
Strain Relief Bushing
80109
1
6
Power Supply Cord
80232
1
7
Heat Shield
891861
1
8
10AB x 3/8 Hex Screw
83172
12
N/S #12 x 3/4 Teks Screw
C23799
4
ASSEMBLY INSTRUCTIONS
Step 1:
THE BLOWER ASSEMBLY MUST BE
DISCONNECTED FROM THE SOURCE OF ELECTRICAL
SUPPLY BEFORE ATTEMPTING THE INSTALLATION.
With pliers, cut the 6 micro-joints and remove panel.
Note: Discard the panel.
Step 2:
Fix the assembly to the back of the stove with
the four screws provided.
THE BLOWER ASSEMBLY IS INTENDED FOR USE ONLY
WITH A STOVE THAT IS MARKED TO INDICATE SUCH
USE.
DO NOT ROUTE THE SUPPLY CORD NEAR OR ACROSS
HOT SURFACES!
Blower Assembly
1
2
3
4
5
6
7
8