background image

 

 

 

  _________________________________________________________________________________________ 

      Page 12 of 15                  King Pigeon Communication Co.,Limited.              Ver 1.5    File No.:RTU5025103 

A Professional GSM 3G M2M products manufacturer 

and automation solution provider, since 2005.

 

www.GSM-Gate-Opener.com    [email protected]

 

 

6.4 Digital Input. 

      The RTU5025 equips 2 digital inputs.   

DIN1 special for secure door and automatically armed when door closed, SMS alert send to the 1

st

~6

th

 positon 

number immediately when door opened illegally.   

DIN2 for motion/smoke or other sensors to protect your assets, SMS alert send to the 1

st

~6

th

 positon number 

when there have any alarm occurance. 

On alarming situation,after alert SMS send out,RTU5025 will call the 1

st

 number and next number if there have no 

answering. 

   

 

6.4.1 Arm:                                      Disarm:   

 

 

6.4.2 Define the DIN1/ DIN2 type.

 

 

 

Eg:

1234DIN2NO#

 ,

define the DIN2 as NO(Normally Open) type. 

 

 

6.4.3 Modify the Alert SMS content when inputs alarm(Max. 32

 

characters). 

 

 

E.g.: 

1234M2#Window open alarm!#

 Modify the DIN2 alert SMS 

content to “Window open alarm!”   

DIN1 default alert SMS content: Door opened illegally. 

DIN2 default alert SMS content: DIN2 Alarm. 

 

 

6.4.4 Inquiry the NC/NO type and Alert SMS content of DIN1(2).

 

 

 

 

 

6.4.5 Digital alarm conditions. 

The DIN1/DIN2 will trigger an alarm only under the below two coditions 

 

RTU5025 under the Armed Mode 

 

10mins after the last call in from the authorized numbers. (10mins default,users can modify the time period by 

SMS command:

 

 

 

 

xxx=000~999, unit:minute 

xxx=000: RTU5025 will always disarm untill arm by SMS command. 

 

 

 

 

pwdAA

 

pwdBB

 

pwdDIN

1

NC(NO)#

 

pwdM1(2)#sms conenton# 

#   

   

 

 

pwdMQ# 

 

pwdDxxx# 

 

pwdDIN

2

NC(NO)#

 

Содержание RTU5025 Series

Страница 1: ...ith a FREE call from your mobile phone Remote switching machines with a FREE call from your mobile phone User Manual Ver 1 5 RTU5025 Series Date Issued 2015 03 25 All rights reserved by King Pigeon Co...

Страница 2: ...inquiry status historical data IMEI code and firmware version 13 6 6 Data function 14 7 Important information 15 8 Maintenance 15 9 Warranty 15 Caution Please read this user manual carefully before i...

Страница 3: ...m authorized number then carries out the turn ON OFF action on the first ring Secure Using Caller ID for verification unknown phone calls are ignored SMS confirmation of relay actions door open to the...

Страница 4: ...tors lights pumps generators valves and machines 2 Safety Directions Safe Startup Do not use Gate Opener when using GSM equipment is prohibited or might bring disturbance or danger Interference All wi...

Страница 5: ...twork Flash per 2 seonds Normal status OFF can t connect to SIM card or unregistered to the cellular network Connection Terminals Power Power supply input Positive wire Red _ Power supply input Negati...

Страница 6: ...M Gate Opener com Support GSM Gate Opener com 4 Typical wiring connection 1 RTU5025 for Gate opener Connect the door sensor to DIN1 for door status detection and siren for alarm sound the lock switche...

Страница 7: ...s CP210x USBto UART Bridge for example COM3 Click here to know how to find out the COM Port on your computer 7 Run this configurate software select the COM Port number for example COM3 click Open the...

Страница 8: ...format to the PC under the configuration folder Export csv Export the authorized number list csv format to the PC under the configuration folder All Always Select all the numbers as Always can call in...

Страница 9: ...you cannot call to control the RTU5025 or cannot send or receive any SMS message from it please try to add in front of the country code or the phone numbers 8 Export the Authorized number list to xls...

Страница 10: ...n and always can call in to control E g 1234A016 123456 1502050800 1502051000 to set the phone number 123456 at the 16th position this number can call in to control during Feb 5th 8 00a m 1502050800 t...

Страница 11: ...then open OFF after call in 6 3 4 Who will receive the confirmation SMS when the relay is ON OFF for relay ON for relay OFF ab the ID code of the 1st number a and the caller number b 0 means disable...

Страница 12: ...out RTU5025 will call the 1st number and next number if there have no answering 6 4 1 Arm Disarm 6 4 2 Define the DIN1 DIN2 type Eg 1234DIN2NO define the DIN2 as NO Normally Open type 6 4 3 Modify th...

Страница 13: ...g Arm Disarm Status DIN1 2 status Relay status GSM signal value full is 31 cellular signal weak if lower than 14 AC DC power supply status Inquiry the self check and auto report time 6 5 3 Inquiry cur...

Страница 14: ...n 100pcs RTU5025 only for small project we suggest client using PC software to configurate or read historical data via USB cable or SMS 6 6 1 Enable data function Disable data function 6 6 2 APN call...

Страница 15: ...If the RTU5025 works but fail to send SMS texts switch the power off and on again after one minute Test it after few minutes later or ensure and check the settings are correct and the cellular signal...

Отзывы: