Page 8 of 20 Ver 1.1
GSM SMS Voice Alarm Dialer
GSM Power Monitoring Alarm
3) Contacting the other alarm panel output to GSM Dialer
The user can connect the other Alarm panel
’s digital output to the GSM Dialer’s Digital Input as a
wired detector, so the user can update its alarm panel as GSM SMS Alarm. The connection please
reference the DVR or IP Camera.
5.4 Contacting the Siren, hooter
The user can connect one 9~12V rated siren, or hooter to the GSM Dialer
’s siren output, once alarm
occurrence, this output ports will start the siren or hooter to make sounds. The positive of the siren
connect to the Siren+ port, and the negative of the siren contact to the Siren
– port. Generally, the
siren wire marked red color and black color, the red color is positive and the black color wire is
negative. See below:
5.5 Contacting the Rechargeable Backup Battery
The GSM Dialer equips one rechargeable backup lithium battery that can power on the GSM Dialer for
about 8hours while AC Power goes off. The GSM Dialer will automatically detect the voltage of the
battery, once the voltage lower will charge it automatically. If you are not use the GSM Dialer for lone
time, please remember to disconnect the backup battery. Please install the battery connector to the
socket, please see below:
Notice:
Must open the backside cover then you can contact the battery.
Once the backup battery turn over, the GSM
Dialer cannot work properly, please contact the external 12VDC to charge it firstly. If you want to replace the battery by
a new one, please note the specification of the backup battery is: 3.7V lithium battery 900~ 1200mA. If long time not use