background image

GSM SMS Alarm & Dialer 

-- Ultra Version! 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Inquiry Onsite AC 
Power Status with a 
SMS! 
 
Cost-Effective GSM 
Dialer Solution In 
The Worldwide!

 

User Manual 

RTU5012 

Ver 1.1     

Date Issued: 2013-11-12 

All rights reserved by King 

Pigeon Hi-Tech.Co.,Ltd. 

 

www.GSM-M2M.com

 

 

GSM SMS Voice Alarm Dialer 

GSM Power Monitoring Alarm 

Содержание RTU5012

Страница 1: ... AC Power Status with a SMS Cost Effective GSM Dialer Solution In The Worldwide User Manual RTU5012 Ver 1 1 Date Issued 2013 11 12 All rights reserved by King Pigeon Hi Tech Co Ltd www GSM M2M com GSM SMS Voice Alarm Dialer GSM Power Monitoring Alarm ...

Страница 2: ...ndbook The manufacturer its employees and distributors accept no liability for GSM Network upgrading or SIMCard upgrading due to the technology specifications contained in this handbook 1 Brief introduction 3 2 Safety Directions 3 3 Standard Packing list 4 4 Mainly Features 4 5 Installation and Connection Diagram 5 5 1 Inserting the SIMCard 5 5 2 Making the Outlets for wires 6 5 3Contacting the Wi...

Страница 3: ...ack The GSM Dialer equips 1 wired inputs for IP Camera Alarm Output other alarm panel output to transfer alarm message by SMS over GSM Network The GSM Dialer inbuilt power detection circuit no need any other detector or sensor to monitoring the external power directly Once external power goes off or goes on the GSM Dialer can send SMS or dial upto 6 authorized mobile phones 2 Safety Directions Saf...

Страница 4: ...en alarm occurrence Supports 1 wired zones Dry Contact Type the input can be Normal Close NC Normal Open NO special for IP Camera alarm output or other wired sensor connection Supports verity programmable zone attributes includes Away normal At House or Stay Entrance Zone 24 Hours Sound Zone 24 Hours Silent Zone Local Zone SOS Zone Door Bell Zone The SMS Alarm Content of the digital input is progr...

Страница 5: ... contact it firstly according to 5 6 b After switched on the GSM Dialer will indicate by a long Di sound all zones LED will turn on once and the zones which registered wireless sensors wireless remote control or wireless buttons will turn on once more In the backside of the GSM Dialer please remove all of the 3 screws and take the back cover off then you can see the PCB See below 5 1 Inserting the...

Страница 6: ...or IP Camera or Other Alarm Panel to the GSM Dialer The GSM Dialer equips one dry contact Normal Close or Normal Open type digital input port the user can connect the IP Camera or CCTV DVR or wired detector or other alarm panel to this port When the digital input triggered by IP Camera or CCTV DVR or wired detectors or other alarm panel it will alarm 1 Contacting the wired Detector to GSM Dialer T...

Страница 7: ...ting the IP Camera or CCTV DVR to GSM Dialer The user can connect the IP Camera or CCTV DVR Alarm Output to the GSM Dialer s digital input as a wired detector once the IP camera detected intrusion or CCTV DVR alarming the GSM Dialer will send SMS to the preset numbers and dial the preset number and make sounds by the siren This is very useful for lots of application that need IP Camera and Alarm i...

Страница 8: ...sitive and the black color wire is negative See below 5 5 Contacting the Rechargeable Backup Battery The GSM Dialer equips one rechargeable backup lithium battery that can power on the GSM Dialer for about 8hours while AC Power goes off The GSM Dialer will automatically detect the voltage of the battery once the voltage lower will charge it automatically If you are not use the GSM Dialer for lone ...

Страница 9: ...damage the GSM Dialer the enclosure reserved one hole at the top side please remove it and fix the external GSM Antenna through this hole 5 7 Contacting the AC DC Power Supply Please contact the 12VDC to the GSM Dialer the Positive of the 12VDC connect to the PWR the negative of the 12VDC please contact to PWR Generally the red color from the AC DC Adaptor is Positive and the black color is negati...

Страница 10: ...s are through SMS commands please edit the below SMS commands in your cell phone then send to the GSM Dialer Tips The GSM Dialer cannot support PIN Code Protected SIMCard Please ensure you have disabled the PIN Code of the SIMCard otherwise can not register GSM Network successful 3 You can program the GSM Alarm Dialer GSM Dialer with SMS commands using your phone It is safe to do so because in add...

Страница 11: ...mands that you will certainly use in the GSM Alarm Dialer GSM Dialer are the following 6 1 Setup New Password if successful the unit will return new password This is the New Password please remember it carefully The password is 4digits For example the original password is 1234 you want change it to 6666 then you can send the command below 1234P6666 For example In China the country code is 0086 or ...

Страница 12: ... from its mobile phone When the user leave the home or store or office dial the GSM Dialer again the GSM Dialer will be changed to away armed mode and return SMS Armed to ensure the armed operation is successful Tips When any number with this value call in the GSM Dialer the GSM Dialer will change from Stay to Armed or Armed to Stay if the GSM Dialer in Disarmed mode then the first time call in wi...

Страница 13: ...hen alarm occurrence the GSM Dialer will send the SMS Alarm Content to the authorized numbers by SMS Max 40 characters can not be empty otherwise the GSM Dialer will return SMS Alarm Content cannot be set as empty E g if you want to receive SMS Alarm content of the wireless zone 00 is intruder breaking the windows and password is 1234 then you can send SMS 1234B00 intruder breaking the windows 6 7...

Страница 14: ... 7 8 9 the siren will not sound 2 e g if want to setup the attributes of wired zone as 5 stands for 24hours emergency silent zone the password is 1234 then please send 1234D00 5 6 9 Setup the Siren Sound time Default is 180seconds If setup successful will return Siren ON xxx Seconds E is the identification character of this command Xxx 000 999 unit is second 3 digits Default is 180 seconds E g if ...

Страница 15: ...n 2 Code 1 can dial in to change the status from Stay to Arm to listen on site 6 14 Setup External Power Status Alert Feature Default is 30 minutes If send successful will return SMS M is the identification character of this command Xx 00 99 Default is 30 Unit is minute Xx 00 stands for when external AC Power goes off will send SMS AC Power Goes off to all authorized numbers or send SMS AC Power G...

Страница 16: ... picked up or rejected the GSM Dialer will dial all of the authorized numbers 3 times in cycle then stop to dial any more Meanwhile the GSM Dialer will enter to previous status 2 Only the zone attribute code setup as 0 1 2 3 4 will cause the siren sound while alarm occurrence And the siren will sound about 20 seconds then interrupt about 2 seconds the time according to the setting 3 Once any zone ...

Страница 17: ...interface of these tools please see below xxxxEE xxxx stands for the password 4 digits Return SMS Armed or Disarmed AC Power ON or AC Power off GSM Value is 17 or other value IMEI Code xxxxxxxxxxxxxxxxxx Example 1111DD When the Password is 1111 xxxxDD xxxx stands for the password 4 digits Return SMS Siren OFF Example 1111CC When the Password is 1111 xxxxCC xxxx stands for the password 4 digits Ret...

Страница 18: ...Dialer off and switch it on after one minute Test this system after another minute or check the settings are correct and the GSM Signals are strong enough 3 If the GSM Dialer can run and sensors work but cannot send SMS texts please change SIM Card to check it 4 If the problem cannot be solved please contact the distributor or manufacturer 10 Warranty 1 This system is warranted to be free of defec...

Страница 19: ...quiry Status GSM Signal IMEI pwd EE 1234EE Password is 1234 6 Setup New Password pwd P newpassword 1234P6666 7 Setup Authorized number pwd Serial Number A Function 1 Code Function 2 code Telephone Number See 6 2 8 Inquiry the Authorized number pwd A 9 Remove Authorized Number pwd SerialNumber A 10 Modify wired zone type as NC pwd NC Default is NC 11 Modify wired zone type as NO pwd NO 12 Modify th...

Страница 20: ...FF Alert at once pwd M 00 22 AC Power Goes OFF Alert after 01 99 minutes pwd M xx Default is 30minutes 23 Siren Response to Arm Operation pwd ON Default 24 Siren NOT Response to Arm Operation pwd OFF 25 Automatically report Status function pwd T xx 00 99hours default is 00 means disabled The End ...

Отзывы: