Data Function
Setup
Contact ID server
IP and Port
1234
apn name
APN
;
user name password #
;
1234 IP address
IP
;
port number#
GPRS Data Function (for engineer only)
1234APNeverywhere;
eesecure;secure#
1234IP175.164.49.20;4005#
For engineer and remote server system only.
Please ignore this part if the total quantity of the alarm system deployed less than 200pcs.
Alert SMS GPRS data to CID Server system Alarm dial out
GPRS/UMTS data upload to server system depends on the alarm events(trigger)
automatically, data connection off line when data send complete.
The alarm system can't receive data from server.
GPRS/UMTS data following the Contact ID (SIA DC-9) protocol.
Alarm Process
AC/DC power lost
AC/DC power recovery
Remote Control SOS
Zone #1 alarm
Zone #2 alarm
Zone #3 alarm
Zone #4 alarm
Wireless zone #5 alarm
Wireless zone #6 alarm
Wireless zone #7 alarm
Wireless zone #8 alarm
Wireless zone #9 alarm
Wireless zone #10 alarm
Wireless zone #11 alarm
Wireless zone #12 alarm
Wireless zone #13 alarm
Wireless zone #14 alarm
Wireless zone #15 alarm
Wireless zone #16 alarm
Wireless zone #16 alarm
Wireless zone #17 alarm
…
Wireless zone #99 alarm
Wireless sensor’s battery
low power alert
AC Power Goes off
AC Power Goes on
Remote Key SOS Help!
SOS Help!
Tamper Switch Alarm
Wired Zone 3 Alarm!
Wired Zone 4 Alarm!
Monitor Zone Alarm!
Entrance Alarm!
Zone 7 Alarm!
Zone 8 Alarm!
Zone 9 Alarm!
Zone 10 Alarm!
Zone 11 Spot Alarm!
Smoke Detector Alarm!
Water Leakage Alarm!
Gas Leakage Alarm!
Panic Help Alarm!
Emergency Silent Alarm!
Zone 16 Alarm!
Zone 17 Alarm!
…
Zone 99 Alarm!
Zone xx low voltage alert!
SMS Content list
Default: AC Power Goes off 30minutes
SOS button on remote control pressed.
SOS button on panel pressed.
Tamper switch on the back side triggered.
Wired zone 1 sensor triggered.
Wired zone 2 sensor triggered.
For monitoring zone only.
For SM-100 or other smoke detector (*optional)
For WL-100 (*optional)
For GL-100/GL-100A (*optional)
For EM-60/EM-100 (*optional)
For EM-70/EM-90 (*optional)
Works for the sensors with low
batter alarm functions only.
Event
SMS Content
Remarks
27