The special zone type for take care of elderly, FIXED in
only.
the 5th zone
System sends alert SMS to the 1st receiver if the sensor did not triggered during monitoring
time period, this function works on
only, if you changed the system
Stay Home Arm mode
to Away Arm or Disarm status, the monitoring function will be ignored automatically.
The purpose of this Monitoring Zone:
Take care of elder people’s activities on daily life.
For example, install one wireless door sensor at your Dad
’
s bed room,
setting the monitoring time period at 05:30~09:00,
If he didn
’
t get up (didn
’
t open his door) during that time,
The monitoring alarm send SMS only, no alarm call or audible alarm sound.
Recommend sensors:
Wireless door sensors, Curtain PIR motion sensors.
Unique Monitoring Zone (the 5th zone)
A bypassed zone will not set off the alarm no matter how
Bypass definition:
often it is tripped. With this function, you can bypass an upstairs window so that you can
leave it open during the day without having to worry about it setting off your alarm.
For example, you want to be able to open and close a specific window during the night,
while your system is armed; You want to bypass a certain motion sensor so that a person
or pet can move through an area without creating an alarm event; While you are making
repairs or renovations to your home, a sensor may be temporarily displaced - and you still
want to use your system to protect the rest of the house.
How to Bypass a specific zone?
Step 1
Enter the two-digit number for the zone you want to bypass, single digit zones must be
preceded by a zero, for example, "03", "06", or "09", etc.
Step 2
Press the Disarm button, wait for the LCD display a "
" message, the zone
Zone xx Bypass
bypassed confirmed.
How to Cancel a Bypass zone?
Press the Arm or Stay Home Arm button to arm your system as usual and enter the
password, bypass zone function canceled.
Bypass Zone Function
17
18