background image

GSM Security Alarm 

GSM SOS Call Syste

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

An Advanced 
Programmable 
Multifunctional 
GSM Auto-Dialer 
GSM Alarm Panel 
In The Worldwide!

 

User Manual 

Ver 1.1     

Date Issued: 2013-02-01 

All rights reserved.

 

K2 

Содержание K2

Страница 1: ...GSM Security Alarm GSM SOS Call System An Advanced Programmable Multifunctional GSM Auto Dialer GSM Alarm Panel In The Worldwide User Manual Ver 1 1 Date Issued 2013 02 01 All rights reserved K2 ...

Страница 2: ... GSM Network upgrading or SIMCard upgrading due to the technology specifications contained in this handbook 1 Brief introduction 3 2 Safety Directions 3 3 Standard Packing list 4 4 Mainly Features 4 5 Installation and Connection Diagram 5 5 1 Inserting the SIMCard 5 5 2 Contacting the Siren hooter 6 5 3 Contacting the AC DC Power Supply 6 5 4 Switching on off the K2 6 5 5 Amounting the K2 6 6 Sett...

Страница 3: ... K2 call back to create two way voice communication Moreover the K2 supports Android Apps and iOS though the Android Apps the user can quickly to Arm Disarm Inquiry Status and Switch ON or OFF Siren armed or disarmed with free call no need to program the SMS commands every time The K2 equips 1 Big SOS button this button can be programmed as SOS armed stay disable functions 2 Safety Directions Safe...

Страница 4: ...d wireless detectors Supports 16 Wireless Zones can accept one learning code wireless detector in each zone and accept unlimited PT2262 2272 fixed code wireless detectors in each zone Supports verity programmable zone attributes includes Away normal At House or Stay Entrance Zone 24 Hours Sound Zone 24 Hours Silent Zone Local Zone SOS Zone Door Bell Zone The SMS Alarm Content of each zone is progr...

Страница 5: ... can connect one 9 12V rated siren or hooter to the K2 Panel s siren output once alarm occurrence this output ports will start the siren or hooter to make sounds The positive of the siren connect to the Siren port and the negative of the siren contact to the Siren port Generally the siren wire marked red color and black color the red color is positive and the black color wire is negative See below...

Страница 6: ...ccess the system by chance 4 Remember that commands must be CAPITAL LETTERS It is PWD not pwd CAP not Cap etc Don t add spaces or any other character 5 The pwd in the commands is means the password when you use it please in stand of it by the digital number 6 While setup phone numbers please try to plus the country code or remove country code E g 008613500001111 or 13500001111 7 Please write down ...

Страница 7: ... alarm SMS to this number doesn t dial 3 stands for when alarm occurrence the K2 only dial this number doesn t sends SMS Function 2 Code 1 2 3 It is for accessing K2 attribute setting 1 stands for when this number dial to the K2 will be rejected after the first ring meanwhile the K2 will be changed to Stay Mode and not return SMS This is very useful when the user come back home or office to change...

Страница 8: ... E g if you want to receive SMS Alarm content of the wireless zone 05 is intruder breaking the windows and password is 1234 then you can send SMS 1234B05 intruder breaking the windows 6 6 Inquiry the SMS Alarm Content Setting If setup successful will return the zone number s SMS Alarm Content 6 7 Setup the Zone Attribute If setup successful will return the zone number s Attribute code D is the ide...

Страница 9: ...he siren will not sound 2 More than one zone attribute can be setup in one SMS Command but don t exceed the SMS character limitation e g if want to setup the attributes of wired zone 01 wireless zone 02wireless zone 03 wireless zones 08 wireless zone the password is 1234 then please send 1234D00 0 D01 1 D02 4 D03 6 D08 9 6 8 Inquiry the Zone Attribute If send successful will return the zone attrib...

Страница 10: ...number The SMS content is Armed By Telephone number or Disarmed by Telephone number Disable this function SMS Command is pwd J 6 13 Required the K2 callback If send successful the K2 will call back the user immediately It is special for the Authorized Number that Function 2 Code 1 can dial in to change the status from Stay to Arm to listen on site 6 14 Setup External Power Status Alert Feature Def...

Страница 11: ...t the K2 Panel again After this operation all the registered wireless detectors and wireless panic buttons and Remote Controls will be removed from the K2 Panel and all of the settings will be reset to the factory default 7 Zone Settings 7 1 Registering the wireless sensor remote control wireless buttons to the K2 Tips a After registered the wireless sensor remote control or wireless buttons must ...

Страница 12: ...tch Combination Remote Control Corresponding Table Switch combination Zone Number Corresponding Table Zone Number Switch Position 4 8 SWTICH 4 SWTICH 5 SWTICH 6 SWTICH 7 SWTICH 8 Notice The value in the table for each zone corresponding the position of the switch 0 stands for OFF side 1 stands for ON side So the 01 zone should setup as the 02 zone should be setup as The 15 zone should be setup as ...

Страница 13: ... the K2 in the learning mode then switch the corresponding switch combinations from OFF to ON one by one and trigger the wireless detector see Notice the K2 will learn the code from the wireless detector automatically When alert by long Di sounds means the wireless detector was learned to the zone position please switch the switches back to OFF Meanwhile please switch off the wireless detector oth...

Страница 14: ...d the A0 A7 and D0 D3 different from each wireless detectors If configured the A0 A7 and D0 D3 are the same the system will treat them as the same one sensor So if you want to add more than one wireless detector to any zone please configure the jumpers as the same in the wireless detectors 4 Also please check the Resistors value is 3 3M Ohm there re 3 Jumpers 1 5M 3 3M and 4 7M if you select incor...

Страница 15: ...ation Armed Away In this mode any detector triggered will cause alarm It be used for away the home and need to protect all of the home or office or store etc Stay Partial armed at home in this mode only the outer zones and emergency zones triggered will cause alarm the inner zone triggered will not cause alarm It be used for partial armed e g some people at home and need to monitoring the outer se...

Страница 16: ...D Card Reader with authorized access signal the K2 disarms immediately Under this status any detector triggered the K2 will not alarm Except the zone attribute is the 24 Hour Emergency Zones Press the button on the remote control or the wireless or wired Stay button the K2 enters Stay Partial Armed status the zones attribute had been set as outer zone and 24 hours emergency zone triggered will cau...

Страница 17: ... the Siren 8 3 4 Switch OFF the Siren 8 4 Inquiry Status and GSM Module IMEI Code xxxxEE xxxx stands for the password 4 digits Return SMS Armed or Disarmed AC Power ON or AC Power off GSM Value is 17 or other value IMEI Code xxxxxxxxxxxxxxxxxx Example 1111DD When the Password is 1111 xxxxDD xxxx stands for the password 4 digits Return SMS Siren OFF Example 1111CC When the Password is 1111 xxxxCC x...

Страница 18: ...g code wireless detector in each zone and accept unlimited PT2262 2272 fixed code wireless detectors in each zone Remote Control 3 Wireless Frequency 433Mhz Wireless Distance 100m in open air Backup Rechargable Battery 3 7V 900 1200mAH lithium batteries Net Weight 0 50Kg 10 Warranty 1 This system is warranted to be free of defects in material and workmanship for one year 2 This warranty does not e...

Страница 19: ...arm 2 06 Wireless Zone 6 Alarm 2 07 Wireless Zone 7 Alarm 2 08 Wireless Zone 8 Alarm 1 09 Wireless Zone 9 Alarm 1 10 Wireless Zone 10 Alarm 1 11 Wireless Zone 11 Spot Alarm 3 12 Smoke Detector Alarm 4 13 Water Leakage Alarm 4 14 Gas Leakage Alarm 4 15 Panic Help Alarm 4 16 Emergency Silent Alarm 5 K2 Authorized Number Schedule SIMCard Number in the K2 ___________________ Serial Number User Name Ph...

Страница 20: ... A 10 Modify the SMS Alarm Content pwd B ZoneNumber SMS Alarm Content 1234B05 intruder breaking the windows 11 Inquiry the SMS Alarm Content pwd B Zonenumber 1234B01 12 Setup the Zone Attribute pwd D Zonenumber Attribute Code See 6 8 13 Inquiry the Zone Attribute pwd D 14 Setup the Siren Sound time pwd E xxx 1234E060 Default 180S 15 Setup the Alarm Delay Time pwd F xxx 1234F999 Default 000S 16 Set...

Отзывы: