2. GENERAL SPECIFICATION
The King Innovation KING 95 Digital Milliamp Clamp Meter is
ideal for use in troubleshooting two-wire irrigation, landscape
lighting and electrical systems. The KING 95 is for use in
indoor and outdoor dry locations.
Digital Display:
4 digit liquid crystal (LCD) maximum reading 6000
Polarity:
When a negative signal is applied, the “ “ signal appears.
Low Battery Indication:
When the battery voltage is below that required for proper
operation when the symbol will appear on the LCD
display.
Sample Rate:
2 times/sec for digital data.
Power Source:
1.5 size AAA battery X 2
Typical battery life: (without buzzer, backlight)
40 hours at ACmA and ACA function;
60 hours at DCV and Ohm function. (alkaline battery)
Auto Power Off:
If a key is not pressed or dial operated for 30 minutes, the
meter will power itself off to save battery life. This function can
be disabled by pressing and holding the “
HOLD
” button and
powering on the unit.
Over Load:
When the applied signal is larger than the maximum for the
range in use the display will show
OL
.
Maximum Jaw Opening:
.79” (20mm)
Dimensions:
8.27” x 2.87” x 1.50” (210 x 73 x 38mm)
Accessories:
Carrying case, batteries, test leads and instruction manual.
3. ELECTRICAL SPECIFICATION
The accuracy specification is defined as ± (percent of reading
+ digit) at 23±5°C,
≤
80 %RH.
Safety Class - CAT III 600V
3-1 AC
m
A (True RMS)
Zero correction: Fractions smaller than approximately 0.006
mA are calibrated to zero.
Low Pass Filter
3-2 ACA (True RMS)
Low Pass Filter
Range
Resolution
Accuracy
50~60Hz
60~500Hz
6.000mA
0.001mA (1μA)
1.0% + 8dgts
2.0% + 8dgts
60.00mA
0.01mA (10μA)
1.0% + 5dgts
2.0% + 5dgts
600.0mA
0.1mA (100μA)
Range
Resolution
Accuracy
6.000mA
0.001mA
2.0% + 8dgts
60.00mA
0.01mA
2.0% + 5dgts
600.0mA
0.1mA
Range
Resolution
Accuracy
6.000A
0.001A
2.0% + 5dgts
60.00A
0.01A
Range
Resolution
Accuracy
50~60Hz
60~500Hz
6.000A
0.001A
1.0% + 5dgts
2.0% + 5dgts
60.00A
0.01A