MILLIAMP CLAMP METER

INSTRUCTION MANUAL

2. GENERAL SPECIFICATION
The King Innovation KING 95 Digital Milliamp Clamp Meter is 

ideal for use in troubleshooting two-wire irrigation, landscape 

lighting and electrical systems. The KING 95 is for use in 

indoor and outdoor dry locations.

Digital Display: 

4 digit liquid crystal (LCD) maximum reading 6000

Polarity: 

When a negative signal is applied, the “      “ signal appears.

Low Battery Indication: 

When the battery voltage is below that required for proper 

operation when the         symbol will appear on the LCD 

display.

Sample Rate: 

2 times/sec for digital data.

Power Source: 

1.5 size AAA battery X 2 

Typical battery life: (without buzzer, backlight) 

 

40 hours at  ACmA and ACA function; 

 

60 hours at DCV and Ohm function. (alkaline battery)

Auto Power Off: 

If a key is not pressed or dial operated for 30 minutes, the 

meter will power itself off to save battery life. This function can 

be disabled by pressing and holding the “

HOLD

” button and 

powering on the unit.

Over Load: 

When the applied signal is larger than the maximum for the 

range in use the display will show 

OL

.

Maximum Jaw Opening: 

.79” (20mm)

Dimensions: 

8.27” x 2.87” x 1.50” (210 x 73 x 38mm)

Accessories: 

Carrying case, batteries, test leads and instruction manual.

3. ELECTRICAL SPECIFICATION
The accuracy specification is defined as ± (percent of reading 

+ digit) at 23±5°C, 

80 %RH.

Safety Class - CAT III 600V

 

3-1 AC

m

A (True RMS)

Zero correction: Fractions smaller than approximately 0.006 

mA are calibrated to zero.

 

Low Pass Filter

 

3-2 ACA (True RMS)

 

 

Low Pass Filter

Range

Resolution

Accuracy

50~60Hz

60~500Hz

6.000mA

0.001mA (1μA)

1.0% + 8dgts

2.0% + 8dgts

60.00mA

0.01mA (10μA)

1.0% + 5dgts

2.0% + 5dgts

600.0mA

0.1mA (100μA)

Range

Resolution

Accuracy

6.000mA

0.001mA

2.0% + 8dgts

60.00mA

0.01mA

2.0% + 5dgts

600.0mA

0.1mA

Range

Resolution

Accuracy

6.000A

0.001A

2.0% + 5dgts

60.00A

0.01A

Range

Resolution

Accuracy

50~60Hz

60~500Hz

6.000A

0.001A

1.0% + 5dgts

2.0% + 5dgts

60.00A

0.01A

Содержание 42095

Страница 1: ...KING 95 CLAMP METER INSTRUCTION MANUAL True RMS Milliamp Clamp Meter 42095 3131884...

Страница 2: ...10 C to 60 C 14 F to 140 F 80 RH Altitude Up to 2000 meters Pollution Degree 2 Explanation of Symbols Attention refer to operation instructions Approvals TABLE OF CONTENTS 1 SAFETY INFORMATION 3 2 GE...

Страница 3: ...eter will power itself off to save battery life This function can be disabled by pressing and holding the HOLD button and powering on the unit Over Load When the applied signal is larger than the maxi...

Страница 4: ...uracy 600 0 0 1 1 0 2dgts 6 000K 0 001K 60 00K 0 01K 600 0K 0 1K Range Buzzer Function Ohm 45 4 DESCRIPTION 4 1 Description of the display Auto power off indication Polarity indication Low battery ind...

Страница 5: ...ys To deactivate the LPF feature press and hold the LPF button for 2 seconds The meter will return to normal mode of operation The Cut Off frequency of the low pass filter is about 160Hz with attenuat...

Страница 6: ...ent value is shown on the display Earth leakage current or any small AC current that flows through a ground wire can also be measured by this method NOTE Keeping the cable in the center of the clamp w...

Страница 7: ...display 6 3 DCV Measurement Switch the main function selector to V range Connect the red test lead to the terminal and the black lead to the COM terminal Measure the voltage by touching the test lead...

Страница 8: ...strument the battery symbol will appear on the LCD display and the batteries should be changed Before changing the batteries switch the main dial to OFF and disconnect test leads Open the back cover u...

Страница 9: ...42 N Central Drive O Fallon MO 63366 www kinginnovation com 800 624 4320 MADE IN CHINA REV E 11 20 2020 King Innovation O Fallon MO 63366 42 N Central Drive www kinginnovation com 800 624 4320 HECHO...

Страница 10: ...to adecuado aparece el s mbolo de bater a en la LCD Antes de reemplazar las bater as coloque el dial principal en OFF apagado y desconecte los conductores de prueba Abra la cubierta posterior con un d...

Страница 11: ...taje de corriente directa VCD Cambie el selector de funci n principal al rango V Conecte el conductor de prueba rojo al terminal y el conductor de prueba negro al terminal COM Mida el voltaje tocando...

Страница 12: ...ntalla La corriente de fuga a tierra o cualesquier peque a corriente alterna CA que circule a trav s del cable a tierra se pueden medir mediante este m todo NOTA Mantener el cable en el centro de la p...

Страница 13: ...o bajo hasta que aparezca el s mbolo Para desactivar la funci n filtro de paso bajo mantenga presionado el bot n LPF filtro de paso bajo por 2 segundos El amper metro regresar al modo de funcionamient...

Страница 14: ...1 0 2 d gitos 6 000K 0 001K 60 00K 0 01K 600 0K 0 1K Rango Funci n de indicador ac stico Buzzer Ohm 45 4 DESCRIPCI N 4 1 Descripci n de la pantalla Indicaci n de apagado autom tico Indicaci n de polar...

Страница 15: ...horrar la bater a Esta funci n se puede deshabilitar manteniendo presionando el bot n HOLD y encendiendo la unidad Sobrecarga Cuando la se al aplicada es mayor que el m ximo para el rango en uso la pa...

Страница 16: ...Explicaci n de s mbolos Atenci n Refi rase a las instrucciones de funcionamiento Aprobaciones NDICE 1 INFORMACI N DE SEGURIDAD 3 2 ESPECIFICACIONES GENERALES 4 3 ESPECIFICACIONES EL CTRICAS 5 3 1 Med...

Страница 17: ...AMPER METRO DE PINZA KING 95 MANUAL DE INSTRUCCIONES Valor Real Ra z Media Cuadr tica True RMS Amper metro de pinza en miliamperios 42095 KING 95 CLAMP METER 3131884...

Отзывы: