WARNING!
ALL ELECTRICAL CONNECTIONS MUST BE DONE BY A QUALIFIED ELECTRICIAN. ALL ADJUSTMENTS OR REPAIRS MUST BE
DONE WITH THE MACHINE DISCONNECTED FROM THE POWER SOURCE. FAILURE TO COMPLY MAY RESULT IN SERIOUS
INJURY!
WIRING AND POWER SUPPLY
WARNING:
THIS PLANER IS AVAILABLE WITH A 220V-440V, 3 PHASE MOTOR (MODEL KC-630FX-2) OR A 600V, 3 PHASE MOTOR
(MODEL KC-630FX-6).
NOTE:
A power cord and plug is not supplied with this planer.
The KC-630FX-2 is shipped wired for 220V- 3 phase operation.
The KC-630FX-6 is shipped wired for 600V- 3 phase operation.
IT IS VERY IMPORTANT TO MAKE SURE YOUR ELECTRICAL SYSTEM IS SUITABLE FOR THIS MACHINE, CONSULT A QUALIFIED
ELECTRICIAN TO MAKE SURE THIS MACHINE GETS “HARD WIRED” PROPERLY TO AN ADEQUATE ELECTRICAL SYSTEM.
GROUNDING
This Planer must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current, to
reduce the risk of electric shock. This machine must be properly installed and grounded in accordance with all local codes and ordinances. Not
all outlets or electrical circuits are properly grounded. If you are not sure if it is properly grounded, have it checked by a qualified
electrician.
WARNING:
IF NOT PROPERLY GROUNDED, THIS PLANER CAN CAUSE ELECTRICAL SHOCK, PARTICULARLY WHEN USED IN
DAMP LOCATIONS. TO AVOID SHOCK OR FIRE, IF THE POWER CORD IS WORN OR DAMAGED IN ANY WAY, HAVE IT REPLACED
IMMEDIATELY.
MAGNETIC SWITCH AND EMERGENCY STOP bUTTON
Starting and Stopping the Planer
The magnetic switch (A) Fig.1 which activates the cutterhead and feed rollers
is located on the front left side of the Planer. To turn the Planer “On” press the
green button (B). To stop the Planer, simply press the red “EMERGENCY
STOP” button (C). When pressed, this switch is equipped with a safety feature
that ensures the machine remains “OFF” until the red stop switch is twisted
and released.
FIGURE 1
ELECTRICAL INFORMATION