King Industrial KC-1002C Скачать руководство пользователя страница 6

ELECTRICAL INFORMATION

WARNING!

ALL ELECTRICAL CONNECTIONS MUST BE DONE BY A QUALIFIED ELECTRICIAN. FAILURE TO COMPLY MAY RESULT IN

SERIOUS  INJURY!  ALL  ADJUSTMENTS  OR  REPAIRS  MUST  BE  DONE  WITH  THE  MACHINE  DISCONNECTED  FROM  THE

POWER SOURCE. FAILURE TO COMPLY MAY RESULT IN SERIOUS INJURY!

POWER SUPPLY

WARNING:

YOUR BANDSAW MUST BE CONNECTED TO A 110V-120V,

15-AMP CIRCUIT BREAKER. FAILURE TO CONNECT IN THIS WAY CAN

RESULT IN INJURY FROM SHOCK OR FIRE.

GROUNDING

This  Bandsaw  must  be  grounded.  If  it  should  malfunction  or  breakdown,

grounding provides a path of least resistance for electric current, to reduce

the risk of electric shock. This Bandsaw is equipped with a cord having an

equipment-grounding  conductor  and  grounding  plug.  The  plug  must  be

plugged into an appropriate outlet that is properly installed and grounded in

accordance with all local codes and ordinances.

Your  Bandsaw  must  be  properly  grounded.  Not  all  outlets  are  properly

grounded.  If  you  are  not  sure  if  your  outlet  is  properly  grounded,  have  it

checked by a qualified electrician.

WARNING: 

TO MAINTAIN PROPER GROUNDING OF YOUR BANDSAW,

DO  NOT  REMOVE  OR  ALTER  THE  GROUNDING  PRONG  IN  ANY

MANNER.

WARNING:

IF  NOT  PROPERLY  GROUNDED,  THIS  BANDSAW  CAN

CAUSE ELECTRICAL SHOCK, PARTICULARLY WHEN USED IN DAMP

LOCATIONS.  TO  AVOID  SHOCK  OR  FIRE,  IF  THE  POWER  CORD  IS

WORN OR DAMAGED IN ANY WAY, HAVE IT REPLACED IMMEDIATELY.

110V-120V OPERATION

As received from the factory, your Bandsaw is ready to run for 110V-120V

operation. This Bandsaw is intended for use on a circuit that has an outlet

and a plug which looks like the one illustrated in Fig.1.

WARNING:

DO  NOT  USE A  TWO-PRONG ADAPTOR  FOR  THEY ARE

NOT IN ACCORDANCE WITH LOCAL CODES AND ORDINANCES. NEVER

USE IN CANADA.

EXTENSION CORDS

The  use  of  any  extension  cord  will  cause  some  loss  of  power.  Use  the

chart in Fig.2 to determine the minimum wire size (A.W.G-American Wire

Gauge)  extension  cord.  Use  only  3-wire  extension  cords  which  have

3-prong grounding type plugs and 3-hole receptacles which accept the tool’s

plug.

For circuits that are further away from the electrical circuit box, the wire size

must be increased proportionately in order to deliver ample voltage to the

Bandsaw motor. Refer to Fig.2 for wire length and size.

SAFETY SWITCH

This  machine  is  supplied  with  a  safety  switch  (A)  Fig.3  equipped  with  a

removable safety key (B). To turn the machine ON make sure the yellow

safety key is inserted and pull the switch up, to the ON position. To turn the

machine OFF push the switch to the OFF position. To prevent unauthorized

use of your machine remove the safety key and store it in a secure location.

FIGURE 1

FIGURE 2

PROPERLY GROUNDED OUTLET

CURRENT CARRYING PRONGS

GROUNDING PRONG

Tool’s

Amperage

Rating

3-6

6-8

8-10

10-12

12-16

Cord Size in A.W.G.

Cord Length in Feet

   25     50    100   150
   

18

    

16

    

16

     

14

   

18

    

16

    

14

     

12

   

18

    

16

    

14

     

12

   

18

    

16

    

14

     

12

   

14

    

12

      

-

       

-

FIGURE 3

Содержание KC-1002C

Страница 1: ...INSTRUCTION MANUAL MODEL KC 1002C COPYRIGHT 2018 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC 10 WOOD BANDSAW WITH STAND...

Страница 2: ...ranty does not apply to defects due directly or indirectly to misuse abuse normal wear and tear negligence or accidents repairs done by an unauthorized service centre alterations and lack of maintenan...

Страница 3: ...d get caught in moving parts Non slip footwear is recommended Wear protective hair covering to contain long hair Roll up long sleeves above the elbows 12 ALWAYS WEAR SAFETY GLASSES Always wear safety...

Страница 4: ...usted To reduce the risk of accidental blade contact minimize blade breakage and provide maximum blade support always adjust the upper blade guide and blade guard to just clear the workpiece Caution N...

Страница 5: ...kpiece towards blade or for miter cuts 13 Cast iron tilting table 14 Retractable extension Used to support larger workpieces 15 Rip fence rail with ruler 16 Lower hinged door lock knob Gain access to...

Страница 6: ...GED IN ANY WAY HAVE IT REPLACED IMMEDIATELY 110V 120V OPERATION As received from the factory your Bandsaw is ready to run for 110V 120V operation This Bandsaw is intended for use on a circuit that has...

Страница 7: ...es A Fig 4 with extra holes are opposite one another as shown 3 Slip rubber feet B onto ends of stand legs 4 Place stand upright on level floor and push down until it sits evenly 5 Tighten all hex nut...

Страница 8: ...ap screws D Fig 7 with a 4mm hex key The end cap E may need to be removed 2 Adjust fence body so it is parallel to the miter slot 3 Retighten two cap screws D and replace end cap E INSTALLING MITER GA...

Страница 9: ...n the upper blade guide assembly lock knob A Fig 12 and position the upper blade guide assembly B about half way between the table and the frame Retighten the lock knob 2 Open the front covers by turn...

Страница 10: ...TRACkING NOTE The blade tension must be properly adjusted before tracking the blade Blade tracking refers to the position the blade turns on the wheels while in motion The blade should track in the ce...

Страница 11: ...urther adjustment may be required as follows 6 Loosen the screw D Fig s 17 18 with a 10mm open end wrench and adjust the entire assembly back or forth to just clear the back of the saw blade Tighten s...

Страница 12: ...side surfaces of the trunnion Motor Electrical Frequently vacuum or blow out any sawdust from the motor and around the switches Lubrication All the ball bearings are permanently lubricated They requir...

Отзывы: