background image

ADJUSTING FENCE POSITIVE STOPS

The fence on the jointer is equipped with positive stops at 90 degrees and 45
degrees right and left.

90 DEGREE POSITIVE STOP

To check the accuracy of the positive stops, position the fence at 90 degrees to
the table by making certain the end of index pin (A) Fig. 17, is engaged in notch
in the index collar (B) as shown, and tighten lockhandle (C). Place a square (D)
Fig. 18, on the jointer table and against the fence (E).

If an adjustment is necessary, proceed as follows: 

1. Loosen set screw (F) Fig. 19, in the index collar and loosen the fence locking

handle (C).

2. Tilt the fence (E) Fig. 19, until you are certain the fence is 90 degrees to the

table surface; tighten lockhandle (C) and set screw (F).

3. Set the angle of tilt scale (G) Fig. 19, to the proper degree mark by loosening

screw (H) and adjusting the pointer.

45 DEGREE INWARD POSITIVE STOP

To check the accuracy of the positive stops at 45 degree inward angle tilt,
position the fence (E) Fig. 20, inward as far as possible. Use a combination
square (D), and check to see if the fence is tilted inward accurately at 45
degrees. If an adjustment is necessary, proceed as follows:

1. Loosen lockhandle (C) Fig. 20.

2. Loosen locknut (A) Fig. 21, and turn adjustment screw (B) until the fence (E)

is set accurately at 45 degrees to the table surface.

3. Retighten locknut (A) Fig. 21.

OPERATING CONTROLS

& ADJUSTMENTS

FIGURE 17

FIGURE 18

FIGURE 19

FIGURE 20

FIGURE 21

Содержание 8" Industrial Jointer KC-85FX

Страница 1: ...INSTRUCTION MANUAL COPYRIGHT 2007 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC 6 8 JOINTERS WITH SPIRAL CUTTERHEAD MODEL KC 75FX 6 Jointer MODEL KC 85FX 8 Jointer...

Страница 2: ...indirectly to misuse abuse normal wear and tear negligence or accidents repairs done by an unauthorized service center alterations and lack of maintenance King Canada shall in no event be liable for d...

Страница 3: ...instructions for lubricating and changing accessories 15 DISCONNECT TOOLS Before servicing when changing accessories or attachments 16 AVOID ACCIDENTAL STARTING Make sure the switch is in the OFF posi...

Страница 4: ...having an equipment grounding conductor and grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinance...

Страница 5: ...he jointer to the stand using the four 1 long cap screws and lock washers supplied If the jointer is to be used without the stand shown in Fig 4 we recommend that the jointer be fastened to a supporti...

Страница 6: ...THE CUTTERHEAD BLADE WHEN INSTALLING CUTTERHEAD GUARD To assemble the cutterhead guard insert post D Fig 9 into hole E and tighten locking lever F against flat on post Fig 10 illustrates the cutterhe...

Страница 7: ...ADJUSTING BELT TENSION Correct belt tension is obtained when there is approximately 1 deflection in the center span of the belt A Fig 12 using light finger pressure If an adjustment is necessary it c...

Страница 8: ...ve the fence tilting lever F to obtain the desired angle of tilt retighten locking handle D NOTE The handle D Fig 15 is springloaded and can be repositioned by pulling out the handle and repositioning...

Страница 9: ...ig 19 until you are certain the fence is 90 degrees to the table surface tighten lockhandle C and set screw F 3 Set the angle of tilt scale G Fig 19 to the proper degree mark by loosening screw H and...

Страница 10: ...Fig 24 and turn the two adjustment screws F and G as necessary Retighten locknuts D and E We recommend that the height of the infeed table be adjusted so the table at its highest point will be 1 2mm...

Страница 11: ...FROM THE POWER SOURCE 2 Be extremely careful that your hands do not come in contact with the cutterhead 3 Move the fence to the rear remove the cutterhead guard and lower the infeed table to expose th...

Отзывы: