Power/Speed (POWER):

Regulation from 50% to 100% of the power to the motors. 

This parameter will also weigh on the manoeuvre speed.

Delay between the wings in closing (DELAY)

Regulation of the wings during the closing adjustable from 0 to 

15 seconds.

Pause time (PAUSE):

Regulation of pause time at the end of the manoeuvre, before the 

automatic reclosing from 0 to 90 seconds. The “

AUTO” dip switch 

must be ON.

Obstacle sensitivity (OBSTACLE):

Regulation of intervention time from 0.1 to 3 seconds.

The lower the trimmer is regulated, earlier the central will stop the 

automation in case of impact of the wing against an obstacle.

4 - CONTROL UNIT SETTINGS 

MAX

MAX

MAX

MAX

     A change of the DIP 8 “SLOW” needs the repetition of the programming procedure. It is advised to 

maintain slow-down active to improve gate and motor mechanics life.    

!

     A variation on the setting of “FOR” trimmer (power/speed) requires the repetition of the learning 

procedure (point 2), because of the change of the manoeuvre time. The slowdowns are automatically set in 

the last 15% of the travel.

4B - TRIMMER SETTINGS

4A - DIP-SWITCHES SETTINGS 

DIP

1

ON

OFF

ON

OFF

ON

OFF

FAST

2

STRIKE

3

LAMP

ON

OFF

4

PHO2

ON

OFF

5

AUTO

ON

OFF

6

STEP

ON

OFF

7

SLOW

ON

OFF

8

RADIO

DIP STATUS FUNCTIONING

DESCRIPTION

Opening / Stop / Closing / Stop modality (step by step)
Opening / Pause / Closing (it accepts only opening commands)

Yes automatic reclosing (set by “PAU” trimmer)

No automatic reclosing

Stop and it recloses for 2 seconds in opening (PHO2, working as pneumatic edge)

Stop and it keeps on opening after clearing in opening (PHO2 , working as photocell)

Flashing light

Steady light

Kick-back enabled

Kick-back disabled

Slow-down enabled

Slow/down disabled

Yes rapid automatic reclosing

No rapid automatic reclosing

START radio channel programming procedure (see paragraph 3A)
Pedestrian opening radio channel programming procedure (see paragraph 3B)

If the “

RADIO” dip-switch is set to ON, the START channel is memorized during the programming of the radio transmitter (see 

paragraph 3).

If the “

RADIO” dip-switch is set to OFF, the pedestrian opening channel is memorized during the programming of the radio 

transmitter (see paragraph 3).

5 - DIP-SWITCHES DESCRIPTION 

5A - DIP-SWITCH 1 - RADIO

If the “

FAST” dip-switch is set to ON, the rapid reclosing is enabled. This modality enables to reclose the gate as soon as the 

control unit notices that the photocell range have been occupied and cleared. So, going through the passage, the automatic 

reclosing of the automation will be enabled, without waiting the pause time.

If the “

FAST” dip-switch is set to OFF, the automatic reclosing is disabled

5B - DIP-SWITCH 2 - FAST

If the “

STRIKE” dip-switch is set to ON, the kick-back is enabled (see paragraph 12D). In this way, the control unit will supply a 

voltage swing at the beginning of the opening cycle, and at the end of the closing cycle.

If the “

STRIKE” dip-switch is set to OFF, the kick-back is disabled.

5C - DIP-SWITCH 3 - STRIKE 

(see also paragraph 12D)

If the “

LAMP” dip-switch is set to ON, the power supply given to the lamp (terminals 28,29) is intermittent (see paragraph 12A).

If the “

LAMP” dip-switch is set to OFF, the power supply given to the lamp (terminals 28,29) is direct (see paragraph 12A).

5D - DIP-SWITCH 4 - LAMP 

(see also paragraph 12A)

If the “

PHO2” dip-switch is set to ON, the safety devices in opening and closing, when they intervene, stop the motion of the wings, 

which will open again as soon as cleared (typical functioning of the photocell). 

If the “

PHO2” dip-switch is set to OFF, the safety devices in opening, when they intervene, invert the motion for 2 seconds, and 

then they stop the automation. So, it is necessary to supply a command (by wire or by transmitter) to finish the travel, and close the 

wings (typical functioning of the safety edge). With this setting these safety devices in closing do not intervene.

5E - DIP-SWITCH 5 - PHO2 

(see also paragraph 11B)

If the “

AUTO” dip-switch is set to ON, the automatic reclosing function is enabled. The control unit automatically closes the wings 

after the time set by the “

PAU” trimmer (see paragraph 4B).

If the “

AUTO” dip-switch is set to OFF, the automatic reclosing function is disabled. It is necessary to supply a command (by wire 

or by transmitter) to close the wings.

5F - DIP-SWITCH 6 - AUTO

If the “

STEP” dip-switch is set to ON, the step-by-step function is enabled. Every time the control unit receives an input signal, it 

perform an action. When the automation is stationary, it starts the motor, and when the automation is moving, it stops the motor.

If the “

STEP” dip-switch is set to OFF, the modality OPEN/STOP/CLOSING is enabled. The control unit accepts only commands 

(by wire or by transmitter) in opening. So, when the gate is closed, it opens. When the gate is opening, it keeps opening, and when 

the gate is closing, it opens completely.

The reclosing takes place with the time set by the “

PAU” trimmer, if the “AUTO” dip is set to ON.

Otherwise, it is necessary to give a START command (by wire or by transmitter).

5G - DIP-SWITCH 7 - STEP

If the “

SLOW” dip-switch is set to ON, the control unit is will perform a slowing-down at the end off the opening and closing phase.

If the “

SLOW” dip-switch is set to OFF, the control unit will not perform the slowing-down.

5H - DIP-SWITCH 8 - SLOW

Содержание Star 2230

Страница 1: ...Star 2230 INSTRUCTION MANUAL EN Star 2230 Control unit for 1 or 2 230Vac motors ...

Страница 2: ...1 PRODUCT DESCRIPTION 1A GENERAL DESCRIPTION Signaling led Paragraph 9 Programming buttons Dip switch function setting Paragraph 4A 5 Setting trimmers Paragraph 4b 8 Removable spare fuse ...

Страница 3: ... by trimmer see paragraph 4B Sensibility of the intervention adjustable from 0 1 to 3 sec by trimmer see paragraph 4B Power speed adjustable from 50 to 100 by trimmer see paragraph 4B Input for control by wire to manage start stop and pedestrian opening Double safety inputs closing terminal 13 and opening and closing terminal 14 Input for warning light to signal the wings position see paragraph 12...

Страница 4: ...inals 4 6 7 8 common limit switches 7 Opening limit switch motor 2 8 Closing limit switch motor 2 9 START contact 10 Terminal 9 11 12 COMMON 11 STOP contact 12 Pedestrian opening contact PED 13 Safety devices in closing contact PHO1 14 Safety devices in opening contact PHO2 15 Terminals 16 and 17 COMMON 0V 16 PHOTOCELLS 24Vdc 17 WARNING LIGHT 24Vdc max 3W 18 Electric lock control negative positive...

Страница 5: ...to be free not bridged The control unit activate the contact only if it receive signals from connected contacts If there are no connected devices on the terminal 13 normally closed input PHO1 terminal 14 normally closed input PHO2 and or terminal 11 STOP the concerning inputs must be bridged If there are connected devices on the terminal 13 normally closed input PHO1 terminal 14 normally closed in...

Страница 6: ...inals 4 6 7 8 common limit switches 7 Opening limit switch motor 2 8 Closing limit switch motor 2 9 START contact 10 Terminal 9 11 12 COMMON 11 STOP contact 12 Pedestrian opening contact PED 13 Safety devices in closing contact PHO1 14 Safety devices in opening contact PHO2 15 Terminals 16 and 17 COMMON 0V 16 PHOTOCELLS 24Vdc 17 WARNING LIGHT 24Vdc max 3W 18 Electric lock control negative positive...

Страница 7: ...to be free not bridged The control unit activate the contact only if it receive signals from connected contacts If there are no connected devices on the terminal 13 normally closed input PHO1 terminal 14 normally closed input PHO2 and or terminal 11 STOP the concerning inputs must be bridged If there are connected devices on the terminal 13 normally closed input PHO1 terminal 14 normally closed in...

Страница 8: ... the setting of FOR trimmer power speed requires the repetition of the learning procedure point 2 because of the change of the manoeuvre time The slowdowns are automatically set in the last 15 of the travel 4B TRIMMER SETTINGS 4A DIP SWITCHES SETTINGS DIP 1 ON OFF ON OFF ON OFF FAST 2 STRIKE 3 LAMP ON OFF 4 PHO2 ON OFF 5 AUTO ON OFF 6 STEP ON OFF 7 SLOW ON OFF 8 RADIO DIP STATUS FUNCTIONING DESCRI...

Страница 9: ...ocell If the PHO2 dip switch is set to OFF the safety devices in opening when they intervene invert the motion for 2 seconds and then they stop the automation So it is necessary to supply a command by wire or by transmitter to finish the travel and close the wings typical functioning of the safety edge With this setting these safety devices in closing do not intervene 5E DIP SWITCH 5 PHO2 see also...

Страница 10: ...he programming procedure verify that The motors shut down a few seconds after the end of the programming procedure The control unit respond to the inputs received by wire START terminal 9 pedestrian opening terminal 12 and STOP terminal 11 The control unit respond to the inputs received by transmitter The safety devices connected to PHO1 terminal 13 intervene while the gate is closing and prevent ...

Страница 11: ...mote control for the second wing 12a Choose the point of slow down with the button SET or the button 1 of the transmitter for the first wing and with the button RADIO or the button 2 of the remote control for the second wing 7 Push SET button or a button of the radio transmitter The control unit performs the opening END of learning yellow led turns off 5 The control unit perform a little opening c...

Страница 12: ... a command by wire the START button or a button in the transmitter 5 The gate begins to open 6 Press the command by wire the START button or the button in the transmitter to set the widening of the pedestrian opening 1 Place the wings in closing position 2 RESET press button SET for 2 seconds the yellow led flashes 3 Press START button the yellow led stays on 4 Press button SET the yellow led flas...

Страница 13: ...turning the trimmer clockwise The intervention delay can be set between 0 1 and 3 seconds Thus if the trimmer is set at the minimum then the intervention time is equal to about 0 1 seconds if adjusted to an intermediate position it is equal to about 1 5 seconds while at the maximum the intervention time will be about 3 seconds See also paragraph 11D 8C Trimmer OBS Obstacle sensitivity YELLOW LED S...

Страница 14: ...closing commands neither automatic nor by wire as long as the contact will be opened again The pedestrian opening is a partial opening or total opening if the installer wants it of the wing opened by MOT1 terminals 30 31 32 To activate the pedestrian opening function it is necessary to make the pedestrian opening programming procedure see paragraph 7 The pedestrian opening can be managed by a chan...

Страница 15: ...e the motors absorb more current 11D OBSTACLE DETECTION BY POWER ABSORPTION The control unit has a self test function of the safeties connected to the PHO1 and PHO2 input It switches off the transmitter to check the commutation of the corresponding receiver contact before the execution of each manoeuvre To activate this self test function proceed as follows connect the positive of the photocell tr...

Страница 16: ...King Gates S r l Via A Malignani 42 33077 Sacile PN ITALY Tel 39 0434 737082 Fax 39 0434 786031 e mail info king gates com web www king gates com MADE IN ITALY ...

Отзывы: