background image

Содержание Commercial Plus Softener Series

Страница 1: ...Kinetico water systems Owners Manual Commercial Plus Softener Series Models CP 213s 00 CP 216s 00...

Страница 2: ...CP Softener Series Owners Manual Rev 08 09 Kinetico Incorporated Corporate Headquarters Newbury Ohio 44065 440 564 9111 Product No 111600 Page 2...

Страница 3: ...213 CP216 16 CP213s OD Data Sheet 19 CP216s OD Data Sheet 20 DA 213 OD Data Sheet 21 NR 213 OD Data Sheet 22 Brine Drum Settings 23 Central Brining System Installation 25 4 0 Troubleshooting Ten Steps...

Страница 4: ...llowed it may result in severe physical harm Any tools or materials required during the installation use or maintenance of this equipment will be preceded by this icon Using these specific tools will...

Страница 5: ...gallons CP 213 13 X 54 Tanks Part Number Model Description 11750 CP 213s00 Commercial Plus Softener 13 x 54 Tanks Overdrive 24 x 40 Brine Tank 11153 CP 213s 00 Commercial Plus Softener 13 x 54 Tanks...

Страница 6: ...us Service Flow Charts Requires Alternating Operation Continuous Flow Rate NOTE Number 1 through 8 within the graph represent meter disc setting Rev 08 09 Kinetico Incorporated Corporate Headquarters...

Страница 7: ...er Series Owners Manual Requires Alternating Operation NO rE Number 1 through 8 within the graph represent meter disc setting Incorporated Corporate Headquarters Newbury Ohio 44065 440 564 9111 Produc...

Страница 8: ...This nozzle has a highly accurate and wide range of flow metering capability If an alternative nozzle is used a different meter volume per 360 on the water meter will result To estimate this new volum...

Страница 9: ...drives the regeneration drive pawl which advances the control disc Regeneration drive pawl gearing turbine Jet During the regeneration water is used by the valve to control the sequence For regenerati...

Страница 10: ...the hole in the center of the Control Disc Step 3 Drop the No back Pawl leg into the small loop at one end of the Meter Drive Pawl Spring making sure that the vertical arm of the Meter Drive Spring i...

Страница 11: ...the groove on the Control Disc Step 2 Place the Actuator into the hole in the D O cap There is enough friction that the Actuator will stay in the D O cap Step 3 Set the Balance Piston Spring in the ce...

Страница 12: ...Levels 2 5 In the center there is the regeneration control valve This valve opens after 4 teeth 0 fi liLeY_Eli 6 r on the control disc have engaged This valve then opens and powers the regeneration cy...

Страница 13: ...tream into the top of the resin bed A plastic molded distributor is attached to the top of the control valve The distributor also prevents resin from backwashing out of the tanks Riser Tube A riser tu...

Страница 14: ...ling multiple units in parallel The Central Brining System has features similar to the independent brine tanks however to accommodate multiple systems the brine refill is accomplished by a float mecha...

Страница 15: ...120 F Do not install the Kinetico Softener in an area where the temperature can cause the unit to freeze Damage to the system will result It is recommended that a WQA certified installer perform the...

Страница 16: ...unt of bleach will vary on plumbing size lengths and fixtures On iron bearing water a salt which contains resin cleaning additives is recommended IMPORTANT This does not apply to tannin units NOTE A c...

Страница 17: ...be taken during the installation process to assure that solder and flux do not come in contact with media tanks the control module and related plastic components Proper ventilation must be provided w...

Страница 18: ...drain line higher than 10 feet will inhibit the ability of the venture to draw brine 10 Position the brine drum In Kinetico Softeners the brine drum mixes and stores a solution of salt or potassium c...

Страница 19: ...Tube Power None System Part Numbers CP 213s 00 24 X 40 brine tank 11750 CP 213s 00 no brine tank media separate 11153 CP 213s 00 empty no brine tank 11184 Brine Tank Options Tank Description 24 x 40 B...

Страница 20: ...ube Power None System Part Numbers CP 216s 00 24 X 40 brine tank media separate 11182 CP 216s 00 no brine tank media separate 11168 CP 216s 00 empty no brine tank 11186 Brine Tank Options Tank Descrip...

Страница 21: ...Dimensions width x depth x height 27 x 13 x 60 Weight Operating I Shipping 450 1300 Ibs Connections Inlet I Outlet Connections Custom Adapter and E clip 1 Brass Sweat Fittings Included Drain Connectio...

Страница 22: ...Rate 12 0 gpm Dimensions width x depth x height 27 x 13 x 60 Weight Operating 1Shipping 450 I 300 Ibs Connections Inlet I Outlet Connections Custom Adapter and E clip 1 Brass Sweat Fittings Included...

Страница 23: ...plastic Break off each tab individually until the proper setting is reached The remaining number or letter imprinted on the tab determines the correct setting The drawing at right shows an adjuster tu...

Страница 24: ...notch and extends from the brine drum about 1 inch Brine Well II II II Do not drop the brine valve into the drum Dropping may lower the float cup resulting in an improper setting Brine Valve Installat...

Страница 25: ...t Part 1139 3 Assemble 90 0 elbow Part 3407 and nipple Part 3406 to refill valve Part 4967 4 Install top collar Part 2360 on bent float rod and position it 14 inches from straight end and secure Slide...

Страница 26: ...o vacuum in 0 Check stems missing or not working Replace or add check stems brine position correctly 0 Plugged venturi Clean out Level 3 venturi throat and molded venturi nozzle Do not use a paper cli...

Страница 27: ...Remove and clean brine elbow screen Frequent Regeneration Problem Reason Solution 1 The customer CJ If customers previously owned an electric Explain to the customer how does not unit with timer based...

Страница 28: ...backwash and one faucet at high flow Measure the pressure by placing a gauge on the brine fitting Raise pressure if below 15 psi CJ The prefilter cartridge is plugged Replace prefilter cartridge 3 The...

Страница 29: ...erric iron J Ferric iron is not removable by ion exchange Verify by using the demo softener to determine if iron is removable by ion exchange Add additional equipment if needed J The iron may be finer...

Страница 30: ...oftener Series Owners Manual Notes ____________________ ___________________________________ Rev 08 09 Kinetico Incorporated Corporate Headquarters Newbury Ohio 44065 440 564 9111 Product No 111600 Pag...

Страница 31: ...ftener Series Owners Manual Notes ____________________________________ _____________________ Rev 08 09 Kinetico Incorporated Corporate Headquarters Newbury Ohio 44065 440 564 9111 Product No 11160D Pa...

Страница 32: ...Kinetico water systems OWNERS MANUAL COMMERCIAL PLUS SOFTENER SERIES 2009 Kinetico Incorporated Product No 11160D...