To fit using the preferred cable method proceed as follows-
l)
Mark out and drill 4 off No 14 (6mm) holes in the back face of the fire
opening (inner face of the outer cavity wall in most instances) in the
positions shown below in fig. 17
Fig. 17
Fit the wallplugs provided and screw the fixing eyes securely into the rear of the
fire opening. If the clearance at the rear of the fire is at the minimum specified for
a powerflue application, it may be necessary to bend over the lower fixing eyes
after screwing them fully in to the rear of the outer cavity wall inner face.
Proceed as follows to remove the burner assembly from the firebox :-
m)
Remove the trim. Remove the burner heat shield from the
front of the fire box to allow access to the burner, as shown below in fig. 18
Fig. 18
i)
Break the connection between the pressure test point elbow and the
solenoid block. Remove the four retaining screws securing the burner to the
firebox. The base of the burner unit can now be pulled forward, allowing the
burner to be removed from the fire box. See fig. 19 overpage
20mm
325mm
100mm
500mm
Fireplace Opening
15