SECTION 2
INSTALLATION OF FIRE
2.1
UNPACKING THE FIRE
Carefully lift the fire out of the carton. Remove the loose item packaging carefully
from the front of the appliance. Check the contents as listed :-
Packing Check List - All Models
1off
Fire box / burner assembly,
1off
Boxed fuelbed base, fuelbed insualtion mat, 2 piece ceramic front rail,
and 1 piece fuelbed overlay
1off
Bag of 22 synthetic coals (packed in fuelbed box)
1off
Loose items bag.
1off
Installation & Maintenance Instruction Book
1off
User Instruction Book
1off
Rope Seal (packed in fan unit - Pack 2 of 2)
1off
Boxed Fan Unit & Flue Pipe (Pack 2 of 2)
2.2
MARKING THE FLUE PIPE OPENING ON THE WALL (ALL MODELS)
Drill a pilot hole into the outer leaf of brickwork at a height of 490mm from the
hearth level, centrally about the firebox, then create a square hole 100mm / 4 inch
vertically central to the centre line of the appliance. See fig. 8 below.
NOTE :
If the fire is to be fitted against the inner cavity wall, the inner and
outer cavity walls will require the 100mm / 4 inch hole creating
Fig. 8
10
Inner Cavity Wall
Outer Cavity Wall
490mm to
Centre of Flue
Pipe
Maximum 1.4
metre above
ground level
100mm / 4 inch
square hole
IMPORTANT NOTE :
DO NOT FIT THIS APPLIANCE FAN UNIT ABOVE
A HEIGHT OF 1.4M FROM GROUND LEVEL