SECTION 1
INFORMATION AND REQUIREMENTS
1.0
APPLIANCE INFORMATION
Main injector : (1 off)
Stereomatic Injector Cat 82 – size 380 (NG)
Pilot Type :
Seagas P5-29D
Maximum Gross Heat Input :
5.5 kW
Minimum Gross Heat Input :
3.6 kW
Cold Pressure :
G20 20.0+/-1.0 mbar (8.0 +/- 0.4 in w.g.)
Ignition :
Integral to gas valve
Electrode Spark Gap :
4.0mm
Packed Weight Combustion Chamber : 54.0 kg
Appliance Efficiency Declaration
The efficiency of this appliance has been measured as specified in BS 7977-1 :
2009 and the result is 71%. The gross calorific value of the fuel has been used for
this efficiency calculation. The test data from which it has been calculated has
been certified by BSI. The efficiency value may be used in the UK Government’s
Standard Assessment Procedure (SAP) for energy rating of dwellings.
Fig. 1
Fig. 2
Top View of Combustion
Side View of Combustion
Chamber
Chamber
3
797 mm
728 mm
351 mm
515mm
560mm
351mm
385mm
385mm