at the end of the pump. Pour out old oil then using a suction oil gun inject 500 + 5g of no# 10 hydraulic oil.
Do not overfill. Replace filler screw, release valve and pump handle several times to remove any air.
Cleaning
Hydraulic ram should be wiped clean with soft cloth only. Do not use gasoline, kerosene, or other such
solvents or any abrasive cleanser as cleaning agents and solvents will cause deterioration of the hydraulic
seals.
Storage
Before storage, loosen pump release valve 1-1/2 turns counterclockwise to release pressure in hydraulic
cylinder. Leave valve in this position. Store press level, in a clean environment preferably indoors, in a dry
area to protect from moisture.
WARNING
The Hydraulic ram used in this shop press is designed for use within the press only. It is not suitable for any
other application. DO NOT use this ram for any form of lifting, it is neither designed for nor suitable for lifting
applications.
Repairing Press
There are no user serviceable parts except as outlined above. Only trained, licensed and certified repair
personnel should attempt any repairs or replacing of parts. Any modifications to this Press, except those
performed by the manufacturer, or their designee, will void all warranties both written and implied.