Twin Mount Tenon - AXF2-MTM-2B / AXF3-MTM-2B

Twin Mount Tenon attaches to any 2" pipe tenon (2

C

" O.D. x 4

K

" inches long).  Steel tenons are

required for all mulitiple top mounts to assure adquate strength.  

Mounting and strength requirements to be engineered by others.

Installation Instructions:

Make certain the electrical supply is 

OFF

before starting installation.

1. Fish wires (by others) through MTM and install MTM 

over tenon being careful not to pinch wires.

2. Orient to desired direction and tighten (4) 

C

-16 

set screws.  Torque set screws to 10 foot pounds.

3.

To prevent windmilling, remove tenon set screw, 
drill recess in tenon for screw point, and replace 
screw.

4. Make wiring connections, green-to-ground, white-to-common, and

black-to-voltage.

5. Install fixture per fixture installation instructions.

Axial Flood 20 & 30 Series Mounting Options

Installation Instructions

1. Fish wires (by others) through MTM and install MTM over tenon

being careful not to pinch wires.

2. Orient to desired direction and tighten (4) 

C

-16 set screws.

Torque set screws to 10 foot pounds.

3.

To prevent windmilling, remove tenon set screw, drill recess
in tenon for screw point, and replace screw.

4. Make wiring connections green-to-ground, white-to-common, and

black-to-voltage.

5. Install fixture per fixture installation instructions.

MOUNTING AND STRENGTH

REQUIREMENTS SHALL BE

ENGINEERED BY OTHERS.

End Cap

(4) 

C

"-16 

Set Screws

2" Pipe Tenon

2

C

" Dia.

Multiple Top

Mount (MTM)

Installation Instructions:     

Make certain electrical supply is 

OFF

before starting installation.

2" Tenon Pipe

2

C

" Dia.

Multiple Top Mount (MTM)

(4) 

C

"-16

Set Screws

End Cap

!

!

MOUNTING AND STRENGTH

REQUIREMENTS SHALL BE

ENGINEERED BY OTHERS.

Triple Mount Tenon - AXF2-MTM-3E / AXF3-MTM-3E

The triple mount tenon mounts to any steel 2" pipe tenon (2

C" 

O.D. x 4

K" 

minimum

length).

Tools Required:

Stubby Flat Blade Screwdriver

F

" Allen Wrench

Tools Required:

Stubby Flat Blade Screwdriver

F

" Allen Wrench

Содержание SM2

Страница 1: ...rength requirements shall be engineered by others Stanchion Mount Tenon SM2 The Stanchion Mount SM2 is made to be set directly into concrete Inside diameter of stanchion is 3K inches and will accommodate up to two 2 1 diameter conduits Concrete and soil engineering by others Installation Instructions Make certain the electrical is supply is OFF before starting installation 1 Dig hole to obtain des...

Страница 2: ...EERED BY OTHERS Side Tenon Mount STM 1A Cast vertical slip fitter with heavy extruded side tenon 2 aluminum pipe size tenon 2C O D 2 I D Installation Instructions Make certain electrical supply is OFF before starting installation 1 Remove splice cover 2 Attach side tenon mount to fixture yoke Square slipfitter with fixture and tighten set screws 10 ft lbs 3 Pull field wires through the pole tenon ...

Страница 3: ...l Flood 20 30 Series Mounting Options Installation Instructions 1 Fish wires by others through MTM and install MTM over tenon being careful not to pinch wires 2 Orient to desired direction and tighten 4 C 16 set screws Torque set screws to 10 foot pounds 3 To prevent windmilling remove tenon set screw drill recess in tenon for screw point and replace screw 4 Make wiring connections green to ground...

Страница 4: ...ts not in direct contact with soil shall be warranted against defects of material and or workmanship for a period of 3 years from date of sale Aluminum fixture components in direct contact with soil shall be warranted from defects of material and failure from corrosion for a period of 1 year from date of sale Limit of Liability and General Conditions Only products which are installed used and main...

Отзывы: