Axial Flood

20 & 30 Series Mounting Options 

Installation Instructions

P.O. Box 60080 • 16555 East Gale Ave.
City of Industry, California 91716-0080
626/968-5666 • FAX 626/330-3861

9/17/07           ECN 5287       Status 1

Part No. 93014415

Tools Required

:

Stubby Flat Blade Screwdriver

N

"  Socket Wrench

F

" Allen Wrench

WARNING: Fixtures must be grounded in accordance with local codes or the National Electrical Code.  
Failure to do so may result in serious personal injury.

MAINTENANCE:  A regularly scheduled maintenance program must be established to insure paint coating is
intact, corrosion or structural damage has not occurred, and all mounting arms, rods, nuts and bolts are tight.
Failure to do so could lead to damage or serious personal injury.

Mounting and strength requirements shall be engineered by others.

KEEP THIS SHEET FOR FUTURE REFERENCE.

!

SM2

SMT

AXF2-WM

AXF3-WM

AXF2-MTM2B

AXF3-MTM2B

AXF2-MTM3E

AXF3-MTM3E

AXF2-STM-2B

AXF3-STM-2B

AXF2-STM-3E

AXF3-STM-3E

Wall Mount Tenon - AXF2-WM & AXF3-WM

The wall mount is designed for use with the Axial 20 - 30 Series fixture.  It is designed to be used in
conjunction with a Wall Embedment Bracket (WEB), however, it may be attached to any flat surface.  

Mounting and strength requirements shall be engineered by others.

Stanchion Mount Tenon - SM2

The Stanchion Mount (SM2) is made to be set directly into concrete.  Inside diameter of stanchion is 3

K

"

inches and will accommodate up to two (2) 1" diameter conduits.  Concrete and soil engineering by others.

Installation Instructions:  

Make certain the electrical is supply is 

OFF

before starting installation.

1. Dig hole to obtain desired mounting height and adequate strength for

local soil conditions.

2. Route conduit as required.
3. Embed stanchion directly into concrete. 
4. Fish wires (by others) out through top of stanchion.
5. Install fixture per fixture installation instructions.

CONCRETE AND SOIL

ENGINEERING BY OTHERS

J-Box

(By Others)

Wall Embedment Bracket

(WEB see Installation

Instructions P/N 95294)

Two (2) 

C

-16 x 1

B

"

Long Hex Head Bolts

(1) 

J

-20 x 

L

" Flat Head

End Cap

2" Pipe Tenon

(2

C

" O.D.)

Conduit 

( By Others)

MOUNTING AND STRENGTH

REQUIREMENTS SHALL BE

ENGINEERED BY OTHERS.

Installation Instructions:

Make certain the electrical 

supply is 

OFF

before starting installation.

1. Feed field wires through arm mount.  Install wall mount

securely using 

C

" bolts into WEB (For WEB Installation

Instructions see P/N 95294)

2. Make all wiring connections observing polarity, i.e.; green-

to-ground, white-to-common, and black-to-voltage.   
Attach end cap.

3. Install fixture per fixture installation instructions.

!

!

Tools Required:

F

" Allen Wrench

Содержание SM2

Страница 1: ...rength requirements shall be engineered by others Stanchion Mount Tenon SM2 The Stanchion Mount SM2 is made to be set directly into concrete Inside diameter of stanchion is 3K inches and will accommodate up to two 2 1 diameter conduits Concrete and soil engineering by others Installation Instructions Make certain the electrical is supply is OFF before starting installation 1 Dig hole to obtain des...

Страница 2: ...EERED BY OTHERS Side Tenon Mount STM 1A Cast vertical slip fitter with heavy extruded side tenon 2 aluminum pipe size tenon 2C O D 2 I D Installation Instructions Make certain electrical supply is OFF before starting installation 1 Remove splice cover 2 Attach side tenon mount to fixture yoke Square slipfitter with fixture and tighten set screws 10 ft lbs 3 Pull field wires through the pole tenon ...

Страница 3: ...l Flood 20 30 Series Mounting Options Installation Instructions 1 Fish wires by others through MTM and install MTM over tenon being careful not to pinch wires 2 Orient to desired direction and tighten 4 C 16 set screws Torque set screws to 10 foot pounds 3 To prevent windmilling remove tenon set screw drill recess in tenon for screw point and replace screw 4 Make wiring connections green to ground...

Страница 4: ...ts not in direct contact with soil shall be warranted against defects of material and or workmanship for a period of 3 years from date of sale Aluminum fixture components in direct contact with soil shall be warranted from defects of material and failure from corrosion for a period of 1 year from date of sale Limit of Liability and General Conditions Only products which are installed used and main...

Отзывы: