10. Percent Weighing Mode
10.1
In this mode, scale will weigh goods weight on it, calculate and display its percentage after the
unit-percentage-weight of goods is obtained.
(NOTE: If
% display format is set to 100%, 100.0% or 100.00% in CONFIG-FUNC-PERCEN menu
item, then, the
unit-percentage-weight
is the weight of 1%, 0.1% or 0.01%
)
10.2
To make percent weighing function be available,
CONFIG-FUNC-PERCEN
menu item shouldn’t be
set to
NONE
.
10.3
To enter percent weighing mode, in normal weighing or counting mode, long press
FUNC
key,
WEIGH/COUNT
will be shown, use
ACC
or
key to select
PERCEN
, then press
TARE
to
confirm go to percent weighing mode. The last set unit-percentage-weight will be used.
10.4 In percent weighing mode, the function of
ZERO, TARE, PRINT, SETUP, PRESET TARE, ACC,
SETUP, ON/OFF
are available.
10.5 There’re two ways to obtain the unit-percentage-weight: (1) input weight and its percentage, then
scale calculates the unit-percentage-weight, refer operation of step 10.5.1 (2) weigh samples weight
which percentage is known, refer operation of step 10.5.2
10.5.1 Input weight and its percentage from keypad, and calculate unit-percentage-weight: in percent
weighing mode, press
UNIT
key, When
InP.Pct
is shown, press
TARE
key to enter this mode: Before
input weight, use
or
ACC
key to select the percentage from 1%, 2%, 5%, 10%, 20%, 50% and
100%, this percentage is corresponding to the weight you will input in following steps
10.5.1.2 When
UNIT.KG
is shown, use
or
ACC
key to select the unit of input weight, use
TARE
key
to confirm and go to next. Press
ZERO
key to exit and back to percent weighing mode.
10.5.1.3 When last stored unit-percentage-weight data is shown, use
,
ACC
,
UNIT
key to input new
unit-percentage-weight, press
SETUP
key more than 3s to input decimal point. Press
TARE
key to
confirm and save it, then go back to percent weighing mode. If the calculated
unit-percentage-weight is less than 0.5d, the indicator will display
Pct.Er
and go back to percent
weighing mode.
10.5.2 Obtain unit-percentage-weight by weighing samples weight which percentage is known: in percent
weighing mode, press
UNIT
key, When
InP.Pct
is shown, use
or
ACC
key to select
SPL.Pct,
press
TARE
key to weigh samples (which percentage is known) weight, calculate piece weight. Press
ZERO
key to exit and back to percent weighing mode.
10.5.2.1 When
SPL.Lo
is shown, remove everything from the platter and press
TARE
key to confirm, before
scale is stable,
SPL.Lo
will be flashed. After it is stable, it will go to next step. Press
ZERO
key to
exit and back to percent weighing mode.
10.5.2.2 When
SPL.Hi
is shown, put samples (its percentage is known) onto the scale, Press
TARE
key to
confirm reading weight. Before scale is stable,
SPL.Hi
will be flashed. After it is stable, it will go to
next step. Press
ZERO
key to exit and back to percent weighing mode.
10.5.2.3 After
INP.PCT
being shown, 000000(position of decimal point is determined by