background image

 

                                                                                                             

 

Controller Time 

YYYY/MM/DD 

HH

MM

SS 

Set up controller time 

Year/Month/Day/Hour/Minute/Second. 

2018/01/01 

01

01

01 

Product Serial Number  S/N 

Display device product serial number. 

S/N 

Change Password 

0000~9999 

Set up password lock 

0000 

Output Select 

WIFI/LAN/RS-232  Select data output from offline 

to online 

RS-232 

Buzzer Mode 

ON/OFF 

Setup buzzer. 

ON 

Language Select 

Chinese/ 

English 

Select language 

English 

Barcode Enable 

OFF/ON 

Turn on the barcode enable function and scan the 

barcode before starting to work, or turn off the 

function to start work without scan barcode. 

OFF 

 

IP Address 

LAN 

(STATIC/DHCP) 

IP 

Mask 

Gateway 

STATIC: User can set a static IP address 

manually. 

DHCP: An IP address assigned by network server 

via router automatically. 

 

Select manual setting and fill out an available IP 

address. 

IP

IP address 

Mask

Subnet mask 

Gateway

Default Gateway 

LAN

STATIC 

IP

192.168.0.7 

Mask

255.255.255.0 

Gateway

 

192.168.0.1 

Start Signal Mode 

Motor/Trigger 

Duration of start signal when screwdriver is 

stopped. 

Motor

The start signal disappears when 

screwdriver is stopped.   

Start signal

When the driver is stopped, the start 

switch (press lever plate/ push down/ external 

signal) is released. The start signal disappears. 

Motor 

 

5. Program setting 

Name 

Set Up Value 

Function Description 

Default setting 

Tightening Step 

001~250 

Step can set the speed, target value (torque / time / 

number of turns)... 

01 

Step Name 

****** 

Setup program name, it can 

choose number

capitals and 

lower case letters

number for 

program name. 

****** 

RPM 

 

Setup rotation speed (According 

to screwdriver type 

Please refer to the 

specification of 

screwdrivers 

Option 

Q/C 

Setup tightening target 

Force 

Direction 

CW/CCW 

Setup rotation direction 

CW 

Delay Time 

0.0~9.9 

Setup interval time between screws 

0.8 

Target Thread 

000.1~999.9 

Setup target no. of thread 

005.0 

Target Torque 

 

Setup target torque 

Please refer to the 

specification of 

screwdrivers 

Hi Torque 

000.01~499.99 

Setup max. torque value 

Please refer to the 

specification of 

screwdrivers 

Lo Torque 

000.00~499.98 

Setup min. torque value 

000.00 

Hi Thread 

000.1~999.9 

Setup max. thread value 

999.9 

Lo Thread 

000.0~999.8 

Setup min. thread value 

000.0 

 

 

Содержание KL-TCG

Страница 1: ...KL TCG User Manual Model KL TCG L Model KL TCG KILEWS INDUSTRIAL CO LTD http www kilews com tw Y2F214 1 014 20220112...

Страница 2: ...ethod introduction 5 3 1 Hot key function introduction 5 3 2 Enter setting function page 5 4 Control setting 6 5 Program setting 7 6 Screw setting 8 7 Extra function 8 8 CONFIRM mode 9 9 External outp...

Страница 3: ...e AC 115V 230V Input Frequency 50 60Hz Input Current 6 3A Input Voltage DC 40V Output Current Max 9A Output Power 360W Function Period 1s ON 3s OFF Size 241 x 185 x 127 mm Weight 3 4Kg DC screwdriver...

Страница 4: ...NG signal LED 8 Reverse signal LED 3 OKALL signal LED 9 Disable signal LED 4 Four digit seven segment display for torque value 10 16X4 LCM display setting function 5 ESC button Return Leave Enter sett...

Страница 5: ...2 External wireless module port 7 Barcode scanner USB type A port 3 Software update port 8 Wired communication port 4 Tool connector 9 Output signal port 5 Socket and switch 10 Input control signal po...

Страница 6: ...sound 2 Down button Press 3 seconds to return to the last job sequence after beep sound 3 Up button Press up and down button and release to view tool setting 4 Right button Press for 3 seconds to go t...

Страница 7: ...ctory Default N Y Return to default status and remove all memory data N Torque Uuit Kgf cm N m kgf m lbf in Set up torque display unit Kgf cm Gate Mode None Once Twice None Function off Once Workpiece...

Страница 8: ...rt signal when screwdriver is stopped Motor The start signal disappears when screwdriver is stopped Start signal When the driver is stopped the start switch press lever plate push down external signal...

Страница 9: ...rrors occurs will lock the screwdriver Setting value 3 means when three consecutive errors occurs will lock the screwdriver and so on If the tightening status is OK once it will be recalculated ON Whe...

Страница 10: ...completed properly and so on NA E3 Voltage drop protection When the voltage of the electric screwdriver drops instantly the electric screwdriver will be stopped and the LCM displays this symbol repres...

Страница 11: ...START RUN FWD When the screwdriver is on CN1 2 short When it short CN1 CN2 short When it open CN1 CN2 open CN 2 COM CN 3 CN 4 CN 5 REVERSE RUN BWD When the screwdriver reverse CN5 6 short When it shor...

Страница 12: ...nal disable signal input DISABLE 1 When CN5 CN6 short CLOSE screwdriver cannot be activated 2 When CN5 CN6 open OPEN screwdriver can be activated CN 6 GND CN 7 External confirm signal input CONFIRM 1...

Страница 13: ...roller will keep on sending DATA100 only update date time and column 14 no of total tightening on controller value will remain unchanged 4 Shut off data will be sent after each shut off Use the column...

Страница 14: ...oller TCG Master External device PC AMS PLC Slave External device response to controller CMD100 Controller send to external device DATA100 After Data101 check column 14 of Data 100 to judge if it is a...

Страница 15: ...ata Type String Length Position Description 1 Header CMD DATA100 String 8 Byte 1 8 Header Command code 2 Year 0001 9999 String 4 Byte 10 13 Year 3 Month 01 12 String 2 Byte 15 16 Month 4 Date 01 31 St...

Страница 16: ...34 37 Check Sum 5438 Key Code 10 Device Name 0 1 String 1 Byte 39 Device Name 0 AMS 1 DAS 11 Instruction number 1 255 String 3 Byte 41 43 Instruction number 12 Tail String 1 Byte 45 Tail 13 ASCII cod...

Отзывы: