7
Controller Time
YYYY/MM/DD
HH
:
MM
:
SS
Set up controller time
Year/Month/Day/Hour/Minute/Second.
2018/01/01
01
:
01
:
01
Product Serial Number S/N
Display device product serial number.
S/N
Change Password
0000~9999
Set up password lock
0000
Output Select
WIFI/LAN/RS-232 Select data output from offline
to online
RS-232
Buzzer Mode
ON/OFF
Setup buzzer.
ON
Language Select
Chinese/
English
Select language
English
Barcode Enable
OFF/ON
Turn on the barcode enable function and scan the
barcode before starting to work, or turn off the
function to start work without scan barcode.
OFF
IP Address
LAN
(STATIC/DHCP)
IP
Mask
Gateway
STATIC: User can set a static IP address
manually.
DHCP: An IP address assigned by network server
via router automatically.
Select manual setting and fill out an available IP
address.
IP
:
IP address
Mask
:
Subnet mask
Gateway
:
Default Gateway
LAN
:
STATIC
IP
:
192.168.0.7
Mask
:
255.255.255.0
Gateway
:
192.168.0.1
Start Signal Mode
Motor/Trigger
Duration of start signal when screwdriver is
stopped.
Motor
:
The start signal disappears when
screwdriver is stopped.
Start signal
:
When the driver is stopped, the start
switch (press lever plate/ push down/ external
signal) is released. The start signal disappears.
Motor
5. Program setting
Name
Set Up Value
Function Description
Default setting
Tightening Step
001~250
Step can set the speed, target value (torque / time /
number of turns)...
01
Step Name
******
Setup program name, it can
choose number
、
capitals and
lower case letters
、
number for
program name.
******
RPM
Setup rotation speed (According
to screwdriver type
Please refer to the
specification of
screwdrivers
Option
Q/C
Setup tightening target
Force
Direction
CW/CCW
Setup rotation direction
CW
Delay Time
0.0~9.9
Setup interval time between screws
0.8
Target Thread
000.1~999.9
Setup target no. of thread
005.0
Target Torque
Setup target torque
Please refer to the
specification of
screwdrivers
Hi Torque
000.01~499.99
Setup max. torque value
Please refer to the
specification of
screwdrivers
Lo Torque
000.00~499.98
Setup min. torque value
000.00
Hi Thread
000.1~999.9
Setup max. thread value
999.9
Lo Thread
000.0~999.8
Setup min. thread value
000.0