19
3.6
Either in operation or standby status,
press SET 6 times to configure
extension time for roller,
LED monitor shows flicker,
press UP or DN to adjust extension time
(
Default setting value depends
on screw type, and setting range is 01-12 seconds
)
,
with or without
pressing any key in 3 seconds, setting will be completed with buzzer alert.
3.7
Either in operation or standby status,
press SET 7 times to configure
vibration strength,
LED monitor shows flicker,
press
UP or DN to configure vibration strength
(
Default setting value depends on
screw type, and setting range is 01~10, there are total 10 steps 5v-10v, every
0.5v is a step
)
,
with or without pressing any key in 3 seconds, setting will be
completed with buzzer alert.
3.8
Either in operation or standby status,
press SET 8 times to configure
motor rotation speed,
LED monitor shows flicker,
press UP or DN to configure motor rotation speed for
screw feeder
(
Default setting value depends on screw type, and setting range
is 01~10
)
,
with or without pressing any key in 3 seconds, setting will be
completed with buzzer alert.
3.9
Either in operation or standby status,
press SET 9 times to configure
changeover vibration,
LED monitor shows flicker,
00
is rotate in clockwise and 01 to rotate in counter-clockwise, press UP or DN to
configure vibration changeover
(
Default setting is 00
)
,
with or without
pressing any key in 3 seconds, setting will be completed with buzzer alert.