 Precautions Concerning 

Installation Location

  Be sure to observe the following precautions when 

installing the product.

• 

Do not use the product in a flammable atmosphere.

To prevent the possibility of explosion or fire, do not use the 
product near alcohol, thinner, or other combustible materials, or in 
an atmosphere containing such vapors.

• 

Avoid  locations  where  the  product  is  exposed  to  high 

temperature or direct sunlight.

Do not install the product near a heater or in areas subject to 
drastic temperature changes. For this product's operating and 
storage temperatures, see this specifications.

• 

Avoid high humidity.

Do not install the product in high-humidity locations--near a boiler, 
humidifier, or water supply. For this product's operating and 
storage humidity, see this specifications. Condensation may occur 
even within the operating humidity range. In such cases, do not 
use the product until the condensation dries up completely.

• 

Be sure to use it indoors.

This product is designed for safe indoor use.

• 

Do not install the product in a corrosive atmosphere.

Do not install the product in a corrosive atmosphere or in 
environments containing sulfuric acid mist, etc. This may cause 
corrosion of various conductors and bad contacts of terminals 
inside the power supply leading to malfunction and failure, or in the 
worst case, a fire.

• 

Do not install the product in a dusty location.

Accumulation of dust can lead to electric shock or fire.

• 

Do not use the product where ventilation is poor.

Secure adequate space around the product so that air can 
circulate around it. Allow at least 20 cm of space between the inlet 
and vent holes and any walls or obstructions.

• 

Do not place objects on the product.

Placing objects on top of the product can cause failures (especially 
heavy objects).

• 

Do not install the product on an inclined surface or location 

subject to vibrations.

The product may fall and break or cause personal injury.

• 

Do not use the product in a location where strong magnetic 

or electric fields are nearby or a location where large amount 

of distortion and noise is present on the input power supply 

waveform.

The product may malfunction.

• 

Do not stack more than two units on top of each other.

The units (load booster and master unit) can be stacked, but 
do not stack more than two units on top of each other for safety 
reasons. If you are using multiple load boosters, it is recommended 
that they be mounted on a rack.

POWER

ELECTRONIC LOAD

PLZ2004WHB

POWER

ELECTRONIC LOAD

PLZ2004WHB

POWER

ELECTRONIC LOAD

PLZ2004WHB

I MON

OUT

OUT

TRIG

I MON

OUT

OUT

TRIG

REMOTE

POWER

Do not stack more than two units.

Precautions to Be Taken When 

Moving the Product

 Note the following points when moving or transporting 

the product to the installation location.

• 

Turn off the power switch.

Moving the product while the power is turned on can cause 
electric shock or damage to it.

• 

Have two or more people move the unit.

The unit weighs over 20 kg. Have two or more people move the 
unit. Use extra precaution at inclines and steps.

• 

Remove all wiring.

Moving the product with the wires connected can cause wires to 
break or injuries due to the product falling over.

• 

When transporting the product, be sure to use the original 

packing materials.

Otherwise, damage may result from vibrations or from the 
product falling during transportation.

• 

Be sure to include this manual.

Notation Used in the Guide

• 

In this manual, the PLZ-4W Series Electronic Load is sometimes 
referred to as the 

PLZ-4W Series

 or "booster." In this manual, 

the PLZ-4WH Series Electronic Load is sometimes referred to as 
the 

PLZ-4WH Series

 or "booster."

• 

In this manual, the PLZ2004W Electronic Load is sometimes 
referred to as the 

PLZ2004W.

 In this manual, the PLZ2004WH 

Electronic Load is sometimes referred to as the 

PLZ2004WH.

• 

The following markings are used in the explanations in the text.

WARNING

• 

Indicates a potentially hazardous situation which, if ignored, 
could result in death or serious injury.

CAUTION

• 

Indicates a potentially hazardous situation which, if ignored, 
may result in damage to the product and other property.

Indicates menu settings that you select. The menu item to 
the left of the > symbol is a higher level menu.

Содержание PLZ2004WB

Страница 1: ...wattage The units connected in parallel can be used as a single electronic load The connection of the control cables is easy The control cable used to connect between the master unit and the load booster and between each load booster is one flat cable each There is no power switch The AC input power is turned ON OFF by the master unit Checking the Package Contents When you receive the product chec...

Страница 2: ...dge This is to prevent the possibility of personal injury Purpose Never use the product for purposes other than the productʼs intended use This product is not designed or manufactured for general home or consumer use Input power Line Voltage Use the product within the rated input power voltage range For applying power use the power cord provided see page 7 This product is designed as an equipment ...

Страница 3: ...netic or electric fields are nearby or a location where large amount of distortion and noise is present on the input power supply waveform The product may malfunction Do not stack more than two units on top of each other The units load booster and master unit can be stacked but do not stack more than two units on top of each other for safety reasons If you are using multiple load boosters it is rec...

Страница 4: ...ut terminal Input connector used to connect to the equipment under test 7 AC INPUT connector AC power input connector 8 Serial number 9 Air outlet Air outlet used to exhaust the internal heat using a fan POWER ELECTRONIC LOAD 2000W x xxxV 0 xxxA PLZ2004WB DC INPUT 2000W 1 5 150V 0 400A AC INPUT 100 240V 47 63Hz 200VA MAX J1 J2 PROTECTIVE GROUNDING CONDUCTOR MUST BE CONNECTED TO GROUND DO NOT REMOV...

Страница 5: ... booster Continue connecting all the remaining boosters in the same manner This completes the procedure for connecting the signal wires Load wiring The cautions and things that you need to consider when you are wiring the loads are the same as when you are wiring the loads of the PLZ1004W PLZ1004WH To ensure operational stability see Methods for Ensuring Stable Operation in chapter 1 Installation ...

Страница 6: ... input terminals on the booster using the included load input terminal screw set Bolt M12 25 Spring washer M12 Nut M12 Crimping terminal Be sure to use the included screw set 6 For each of the booster s load input terminals wrap the included auxiliary band around the space between the rear panel and the bolt The auxiliary band prevents the load input terminal cover from slipping Wrap the belt tigh...

Страница 7: ... Unit After you finish making the connections set the number of boosters on the master unit If the master unit s response speed has been set to 1 1 its response speed is changed to 1 2 to ensure operational stability You can use the menu settings to return the response speed to 1 1 1 Turn on the power to the master unit On the master unit from the menu select 2 Configuration 1 Master Slave Operati...

Страница 8: ...e Pin Cleaning the PLZ2004WHB s dust filter 1 Remove the lower louver from the panel While lifting the bottom of the removal mark with your finger tips slide the entire louver to the right Then pull it toward you POWER ELECTRONIC LOAD PLZ2004WHB 2000W 5 650V 0 100A While lifting the bottom of the removal mark with your finger tips slide the entire louver to the right Removal mark Louver 2 Remove al...

Страница 9: ...ally increased from 0 V no current will flow until 0 3 V is exceeded Once a current greater than or equal to 1 of the range rating starts flowing the current can flow at voltages less than equal to 0 3 V 2 Condition in which the booster is connected to the master unit 3 M range applies to the full scale of H range Rating PLZ2004WHB PLZ2004WHB Operating voltage 5 Vdc to 650 Vdc1 Current 100 A Power...

Страница 10: ... on models that have CE marking on the panel 5 This instrument is a Class I equipment Be sure to ground the protective conductor terminal of the instrument The safety of the instrument is not guaranteed unless the instrument is grounded properly 6 Pollution is addition of foreign matter solid liquid or gaseous that may produce a reduction of dielectric strength or surface resistivity Pollution Deg...