PD05M-PCR-LE/PD05S-PCR-LE 1
PART NO. Z1-005-530, I0025001
Sep 2020
PD05M-PCR-LE
PD05S-PCR-LE
Setup Guide
PCR-LE series Parallel Operation Driver
Thank you for purchasing the PCR-LE Series Parallel operation
driver.
This option is used to perform master-slave parallel operation on
the PCR-LE Series AC power supplies (excluding the PCR500LE
and PCR1000LE; up to 5 units (power is 27 kVA or less)). Parallel
operation is possible between different PCR-LE models as long as
the number of units is 5 or less (power is 27 kVA or less).
The PD05M-PCR-LE is used on the master unit.
The PD05S-PCR-LE is used on slave units.
Number of PCR-LE
operated in parallel
Number of PD05M-
PCR-LE (for master)
Number of PD05S-
PCR-LE (for slave)
2
1
1
3
1
2
4
1
3
5
1
4
Features
• Enabling PCR-LE AC Power Supplies to Generate Large-capaci-
ty, Multifunctional High-quality Output
Using this product in combination with 2P05-PCR-LE single-
phase, three-wire output drivers or 3P05-PCR-LE three-phase
output drivers creates a high capacity, multi-phase output AC
power supply.
• Expansion of Output Capacity in the Future or Temporarily (eco-
nomical equipment investment)
Use of the Parallel Operation Driver allows expansion of the output
capacity if a PCR-LE is small capacity and the capacity is to be
increased later. Alternatively, PCR-LE installed singly can be inte-
grated for use if they are generally used at small capacity, but a
large capacity is required due to provisional testing or the like.
Check at Unpacking
Upon reception of the product, confirm that the package contains
the necessary accessories and that the device and accessories
have not been damaged during transportation. If the device is
damaged or any accessory is missing, notify Kikusui distributor/
agent.
Setup Guide
(This sheet, 1pc.)
PD05M-PCR-LE or
PD05S-PCR-LE (1pc.)
PD05M-PCR-LE only
Protection sockets(2 pcs.)
[84-49-0110]
Connecting cable
(70 cm, 1pc.)
[
91-88-0180
]
Power signal cable
(30 cm, 1pc.)
[
91-88-0182
]
PD05S-PCR-LE only
Functional limitations during paral-
lel operation
You will not be able to use the following features when you install
this product.
Power-saving function (only when performing parallel operation
using different models)
High speed response setting (FAST)
Firmware version of PCR-LE
When using the PD05M-PCR-LE/ PD05S-PCR-LE, the PCR-LE must
be required with the firmware version of 3.00 or later. If the firmware
version of the PCR-LE is 2.99 or previous version, the PCR-LE is
required for the firmware update.
When using the PD05M-PCR-LE/ PD05S-PCR-LE, the firmware of
all the PCR-LE series that make up the system must be the same.
To check the firmware version of the PCR-LE, refer to the operation
manual of the PCR-LE series. In case, the PCR-LE needs update,
contact your Kikusui agent or distributor.
Handling Precautions
Handling of the boards
• Ground yourself by touching a grounded metal object before
touching the board.
• Avoid handling the interface board in an environment subject to
strong static electricity.
• For storage, provide electrostatic protection measures such as
the anti-static bag accompanying the interface board.
• Do not drop a board or subject it to other impact.
• Do not install or uninstall the interface board with the power ON
of the PCR-LE Series.
Handling of the cables
• Do not damage the cable.
• Do not pull, bend, or apply any other stress to the cable.