Kikusui LP01-TOS Скачать руководство пользователя страница 1

The LP01-TOS/LP02-TOS Test Probe is a dedicated probe for a KIKUSUI TOS6210/

TOS6200A/TOS6200/TOS6100  Earth  Continuity  Tester.  Its  convenient  shape  allows

faster connection to the device under test (DUT). 

The  LP01-TOS and   LP02-TOS can  measure  until  30 A  and  60 A respectively  in  the

earth continuity test. 

• This product is designed to be used with a KIKUSUI Earth Continuity

Tester. Carefully read the warnings and precautions given in the Earth

Continuity Tester Operation Manual before attempting to use it.

Precautions for Use

Be sure to connect the remote control cable.

Never perform testing using the Tester START switch without the remote con-
trol cable.

Never use the test probe with other earth continuity testers.

The test probe is designed specifically for use with a KIKUSUI Earth Continu-
ity  Tester.  It  cannot  be  used  with  other  earth  continuity  testers,  even  if  the
connector appears to be compatible.

Never use the product at currents over the rated maximum current 

The rated maximum current (see Description *1 on page 7) of the probe is 30
Aac (LP01-TOS) or 60 Aac (LP02-TOS). Use at over currents may result in
fire.

Never touch the contact pin immediately testing is completed. 

If the LP02-TOS is used more than 30 A, the contact pin will be high tempera-
tures. Never touch the contact pin immediately testing is completed. Touching
will result in getting burned. 

Handle the test probe attentively. Do not swing it around.

Do not yank the test probe cable or drape it over any part of your body.

Part No. Z1-003-490, I0027201

Oct 2020

LP01-TOS/LP02-TOS

OPERATION MANUAL

TEST PROBE

NOTE

Содержание LP01-TOS

Страница 1: ...r earth continuity testers The test probe is designed specifically for use with a KIKUSUI Earth Continu ity Tester It cannot be used with other earth continuity testers even if the connector appears t...

Страница 2: ...from the switch will stop testing Contact Pin Test current is delivered to this pin contacting a test point of the DUT Holder This part holds the contact pin OUTPUT LED This red LED indicates that te...

Страница 3: ...epairs Test probe cable and LOW test lead Check for broken sheathing and loose or cracked connectors Confirm electrical continuity Start switch Confirm that the switch operates smoothly when pressed C...

Страница 4: ...OUTPUT LED does not light The on off status of the OUTPUT LED of the test probe is inconsistent with that of the TEST LED on the Tester The OUTPUT LED remains lit even when you release your finger fr...

Страница 5: ...e LOW terminal of the Tester 4 Connect the each cable of the test probe to the HIGH and REMOTE termi nal of the Tester Connecting the remote control cable starts or stops testing as indicated below Te...

Страница 6: ...nect the alligator clip of the LOW test lead to the protective conductor terminal of the DUT 2 Apply the contact pin of the test probe to the test point of the DUT 3 Depress the START switch This caus...

Страница 7: ...i distributor or agent Specifications 1 The rated maximum voltage current refers to the maximum voltage current the test probe is capable of handling within the given operating temperature and humidit...

Страница 8: ...e equipment and quantity SJ T 11364 GB T 26572 GB T 26572 Environment friendly Use Period Pb Hg Cd Cr VI PBB PBDE LP01 TOS LP02 TOS KIKUSUI ELECTRONICS CORP www kikusui co jp en 1 1 3 Higashiyamata Ts...

Отзывы: