KPM1000
Measurement Applications
33
Measuring integrated power
Starting and pausing integration
After you configure the integration settings, start the integration.
Starting integration
Press START/STOP to start integration. The START/STOP LED lights.
While there is still integration time remaining, press START/STOP to pause integration. While
integration is paused, the START/STOP LED blinks. The display of integrated values is held
on displays B and D. Press START/STOP again to continue integration. The START/STOP
LED lights.
Operations during integration
During integration, you can operate the START/STOP, RESET, DSPL A, DSPL B, DSPL C,
DSPL D, HOLD, KEY LOCK, and LOCAL keys. If you press any other key, an error noise
sounds.
In this situation, you cannot change the voltage range, current range, configuration menu
settings, or interface menu settings. You can view the settings. To view the settings, perform
the same key operations that you would perform to configure the settings.
If the auto range feature is turned on, the range is fixed to the range that the KPM1000 is set
to when it starts integration.
Stopping integration
If you have set the integration time, integration stops after the specified time elapses. If you
have not set the integration time, integration continues until you press the START/STOP key.
When the integration time elapses, the START/STOP LED blinks, and integration stops. The
display of integrated values is held on displays B and D. Even after integration stops, you
cannot operate the V RANGE, I RANGE,
▲
,
▼
, CONFIG, and I/F keys until you clear
integration.
Clearing integration
You can clear integration when integration is paused or when the integration time elapses.
Press RESET to clear integration. The START/STOP LED turns off, and the Wh indicator
displays “-----.” At this point you can operate all the keys.
Stopping measurements
After you stop measuring, if necessary, turn off the EUT, and turn off the AC power supply’s
output.
Integrated value
Start
Stop
Hold
Hold
Stop Finish
Start
Integration time
Integrated value
Start
Integration time
Finish
Hold
Check the displayed integrated power (Wh). When you clear integration, the measured
results up to that point are discarded.