![KIFCO Water-Reel B110G Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/kifco/water-reel-b110g/water-reel-b110g_operators-manual_1966535016.webp)
Be sure the ON/OFF valve is in the "OFF" position. Place the Drive Pawls in the "engaged" (down) position.
Turn on the water. Confirm the sprinkler is operating as expected and in the desired arc. After all air is purged
from the system and the sprinkler is operating smoothly, turn the ON/OFF valve to the "ON" position. Set the
Speed Control Valve to the desired retraction speed.
The Speed Control Valve, located on the valve assembly, regulates the speed at which water can fill the
Bellows.
Speed Control Valve
Pawl Rod
ON/Off Valve
ON
Off
Note:
The Water- Reel requires 45 Pounds Per Square Inch (PSI) and adequate water flow capacity
(GPM) to operate properly
. Consult your Kifco dealer if you do not have an adequate water supply.
Observe water pressure, travel speed, and sprinkler performance to confirm desired performance.
See pages 20 or 21 for performance charts.
When the sprinkler cart completes the irrigation run and has contacted the Shut Off Bar, the retraction of the
Tube will stop.
16
With the irrigation run completed, turn off water supply, relieve pressure first, and disconnect. The Water-Reel
is now ready to be moved and set up in a new location
Open Drain to relieve pressure on Supply Hose
after turning off water supply
Important
Drain
Supply Hose
Note:
Some municipalities prohibit the use of water mains intended for fire protection and there may also be
requirements for back-flow prevention. Investigate and obey all local regulations regarding the use of water
.
B110G Bellows Drive Operation