Product Description

BMR410 Controller

Application

The BMR410 is a DDC controller for regulating, 
controlling, monitoring and optimizing heating, ventilation 
and air conditioning systems.
The BMR410 also has a fieldbus to allow for flexible 
enhancement with input and output modules, as well as 
with room control modules.
With an integrated Ethernet interface, the BMR410 has a 
built in web server to facilitate visualization, remote 
control and data backup over a web browser without the 
need of any additional software.
Parameterization can be carried out using the BMRTool, the SI Tool or the PS4000.
Additional main features of the BMR410:

Native BACnet® in accordance with DIN EN ISO 16484-5 (BACnet® server functionality);
facilitates communication with the BMS by Ethernet or modem.

The BMRTool allows you to configure the controller quickly and easily. Plant macros are set to configure the 
BMR410 completely, set the associated BMR software objects, configure the parameters and assign the input 
and output signals.

Simple turn-knob operation with illuminated display

Weekly schedule and annual schedule

Trend data can be saves and visualized

Code keys for quick display and adjustment of plant values at different access levels;
customer-specific plaintext for every parameter

Can be operated in 12 languages (Czech, Dutch, English, French, German, Hungarian, Italian, Latvian, Polish, 
Russian, Spanish and Swedish)

3 closed-loop control circuits for heating or 2 for ventilation, which can be extended by hardware and software 
objects

Malfunction message logging with time and date

Content

Page

Important Information Regarding Product Safety ..................................................................................................2
Item........................................................................................................................................................................3

Technical Data.....................................................................................................................................................3
Accessories (not included in delivery) .................................................................................................................4
Dimensions ..........................................................................................................................................................5
Connectable fieldbus modules.............................................................................................................................6
Connection...........................................................................................................................................................6
Fieldbus Power Supply ........................................................................................................................................8

Installation..............................................................................................................................................................9

Opening the Housing ...........................................................................................................................................9

Removal...............................................................................................................................................................10

Содержание BMR410

Страница 1: ...I Tool or the PS4000 Additional main features of the BMR410 Native BACnet in accordance with DIN EN ISO 16484 5 BACnet server functionality facilitates communication with the BMS by Ethernet or modem...

Страница 2: ...o comply with local regulations Mounting installation and commissioning work on the devices may only be carried out by qualified technicians Qualified technicians are persons who are familiar with the...

Страница 3: ...ade plug For connecting a BMF400 input output module CAN Fieldbus DC 12 V 6 W module power supply 2 000 m 20 kBd RS232 Modem connection for fax SMS and BMS with BACnet in accordance with DIN EN ISO 16...

Страница 4: ...ML2 50 to 150 C BMRTool Configuration tool for BMR Z179 Cascade plug Replacement for power supply and bus cables Connection with cascade plug on the BMR one BMF A386KD Lithium battery with increased...

Страница 5: ...switch cabinet door Installation space one row 144 mm 8 HP 1 BMR for example Z63 Adapter frame for BMR modules Format 19 Installation space one row 288 mm 16 HP 1 BMR and 2 FBU for example Z62 Adapter...

Страница 6: ...on FBS51 04 maximum 1 can be installed on the BMR410 Room control modules DDC110 3 DDC110S DDC110 3S1 DDC110 4 Connection 1 DC 12 V for fieldbus power supply 2 Z179 cascade plug for power supply and c...

Страница 7: ...e ground connection 0 At the end of the fieldbus furthest point from the DDC controller install a terminating resistor of about 180 ohms between both data lines and The terminating resistor is include...

Страница 8: ...supplies you can use a fieldbus length of up to 2000 m Fieldbus Power Supply DC 12 V 6 W NOTE The BMF does not require any additional power supplies as it is supplied over the cascade plug and not fro...

Страница 9: ...anger of death by electrocution Mount or remove only when power is switched off Opening the Housing When mounting or connecting the fieldbus module it may be necessary to open the housing of the BMR41...

Страница 10: ...A Page 10 10 Product Description BMR410 Datasheet 2 70 10 411 01 EN Issue 2011 04 27 Removal WARNING Danger of death by electrocution Mount or remove only when power is switched off 1 2 3 4 5 6...

Отзывы: