CLEANING YOUR ALARM

YOUR ALARM SHOULD BE VACUUMED ONCE A MONTH

If the tamper resist feature has been activated you will need to follow the instructions
in Section 3 to remove your alarm for maintenance.

To clean your alarm, remove it from the mounting bracket as outlined in the
beginning of this section.  You can clean the interior of your alarm (sensing chamber)
by using compressed air or a vacuum cleaner hose and blowing or vacuuming through
the openings around the perimeter of the alarm.  The outside of the alarm can be
wiped with a damp cloth.

After cleaning, reinstall your alarm and test your alarm by using the test button. If
cleaning does not restore the alarm to normal operation the alarm should be replaced.

7.LIMITATIONS OF SMOKE ALARMS

WARNING: PLEASE READ CAREFULLY AND THOROUGHLY

•  Life safety from fire in residential occupancies is based primarily on early notification

to occupants of the need to escape, followed by the appropriate actions by those
occupants. Fire warning systems for dwelling units are capable of protecting about
half of the occupants in potentially fatal fires.  Victims are often intimate with the
fire, too old or young, or physically or mentally impaired such that they cannot
escape even when warned early enough that escape should be possible. For these
people, other strategies such as protection-in-place or assisted escape or rescue are
necessary.

• Smoke alarms are devices that can provide early warning of possible fires at a

reasonable cost; however, alarms have sensing limitations.  Ionisation sensing
alarms may detect invisible fire particles (associated with fast flaming fires) sooner
than photoelectric alarms. Photoelectric sensing alarms may detect visible fire
particles (associated with slow smoldering fires) sooner than ionisation alarms.
Home fires develop in different ways and are often unpredictable. For maximum
protection, Kidde recommends that both Ionisation and Photoelectric alarms be
installed. 

• A battery powered alarm must have a battery of the specified type, in good condition

and installed properly.

• Smoke alarms must be tested regularly to make sure the batteries and the alarm

circuits are in good operating condition.

• Smoke alarms cannot provide an alarm if smoke does not reach the alarm.

Therefore, smoke alarms may not sense fires starting in chimneys, walls, on roofs,
on the other side of a closed door or on a different floor.

• If the alarm is located outside the bedroom or on a different floor, it may not wake

up a sound sleeper.

• The use of alcohol or drugs may also impair one’s ability to hear the smoke alarm.

0310-7201-00.qxd:_  2008.2.25  2:08 PM  Page 8

Содержание PE910UK

Страница 1: ...ortant part of your family s home safety plan You can trust this product to provide the highest quality safety protection We know you expect nothing less when the lives of your family are at stake PE9...

Страница 2: ...as the bedrooms are usually farthest from the exit If more than one sleeping area exists locate additional alarms in each sleeping area Locate additional alarms to monitor any stairway as stairways a...

Страница 3: ...an alarm mounted on the ceiling In such units install the smoke alarm on an inside wall with the top edge of the alarm at a mini mum of 10 cm 4 and a maximum of 30 5 cm 12 below the ceiling see Figur...

Страница 4: ...ng fans or other high air flow areas Kitchens Normal cooking may cause nuisance alarms Near fluorescent lights Electronic noise may cause nuisance alarms Smoke alarms are not to be used with detector...

Страница 5: ...ees The alarm is now activated 2 After installation activation test your alarm by depressing and holding down the test button for a minimum of 5 seconds or until the alarm sounds This should sound the...

Страница 6: ...FEATURE IDENTIFY THE SOURCE OF THE SMOKE AND BE CERTAIN A SAFE CONDITION EXISTS FLASHING LED LIGHT This smoke alarm is equipped with a flashing red indicator light with four modes of operation The LED...

Страница 7: ...to the mounting bracket by rotating in the direction of the arrows on the cover see ACTIVATING ALARM in Section 3 INSTALLATION INSTRUCTIONS This alarm has a low battery monitor circuit which will caus...

Страница 8: ...not escape even when warned early enough that escape should be possible For these people other strategies such as protection in place or assisted escape or rescue are necessary Smoke alarms are device...

Страница 9: ...and wake when it sounds They must wake up in order to execute the escape plan Practice allows all occupants to test your plan before an emergency You may not be able to reach your children It is impor...

Страница 10: ...or those areas separated by a door from the areas protected by the required smoke alarms For this reason it is recommended that the householder consider the use of additional smoke alarms for those ar...

Страница 11: ...rchase postage and return postage prepaid to Warranty Service Department Kidde Safety Europe Mathisen Way Colnbrook Slough Berkshire SL3 OHB This warranty shall not apply to the smoke alarm if it has...

Отзывы: