•  Kitchens. Normal cooking may cause nuisance alarms. If a kitch-

en alarm is desired, it should have an alarm silence feature or be 
a photoelectric type.

•  Near fluorescent lights. Electronic “noise” may cause nuisance 

alarms.

•  Smoke alarms are not to be used with detector guards unless 

the combination (alarm and guard) has been evaluated and 
found suitable for that purpose.

3. INSTALLATION INSTRUCTIONS

      CAUtION: tHIS UNIt IS SeAled.  tHe COVeR IS NOt RemOVABle!

1. Remove the mounting plate from the back of the alarm by hold-

ing the mounting plate and twisting the alarm in the direction 
indicated by the “OFF” arrow on the alarm cover.

2. To insure aesthetic alignment of the alarm with the hallway or 

wall, the “A” line on the mounting plate should be parallel with 
the hallway when ceiling mounting or horizontal when wall 
mounting.

3. After selecting the proper smoke alarm location as described in 

section 1, attach the mounting plate to the ceiling as shown in 
figure 4. For wall mounting see figure 5. Place mounting plate 

FIGURe 6

When wall 
mounting, the 
“A” line should 
be horizontal 
and the “UP 
FOR WALL 
MOUNTING” 
arrow must be 
pointing up.

A

A

A

A

Alignment 

Marks

Install

Remove

FIGURe 5

FIGURe 4

FIGURe 7

When 
mounting in 
a hallway, 
the “A” line 
should be 
parallel with 
the hallway.  

!

Содержание P9040

Страница 1: ...ant part of your family s home safety plan You can trust this product to provide the highest quality safety protection We know you expect nothing less when the lives of your family are at stake Smoke...

Страница 2: ...mmediate area of the bedrooms Try to monitor the exit path as the bedrooms are usually farthest from the exit If more than one sleeping area exists locate addi tional alarms in each sleeping area Loca...

Страница 3: ...aximum of 12 30 5cm below the ceiling see figure 1 Put smoke alarms at both ends of a bedroom hallway or large room if the hallway or room is more than 30 ft 9 1m long Install Smoke Alarms on sloped p...

Страница 4: ...an inside wall For minimum protection install at least one alarm close to the bedrooms For additional protec tion see SINGLE FLOOR PLAN in figure 2 WARNING TEST YOUR SMOKE ALARM OPERATION AFTER RV OR...

Страница 5: ...ate and twisting the alarm in the direction indicated by the OFF arrow on the alarm cover 2 To insure aesthetic alignment of the alarm with the hallway or wall the A line on the mounting plate should...

Страница 6: ...irection indicated by the ON arrow on the alarm cover see figure 7 until it locks in place 7 A tamper resist feature has been provided on the alarm To activate this feature you must break out the tamp...

Страница 7: ...40 45 seconds to indicate that the smoke alarm is receiving power SMOKE SENSING CHAMBER OPERATION This alarm will chirp if any of the components in the smoke sensing chamber fail This chirp will occur...

Страница 8: ...emoval instructions The tamper resist tab will have to be released in order to change the battery To replace the battery remove the alarm from the mounting plate by rotating the alarm in the direction...

Страница 9: ...the appropriate egress actions by those occupants Fire warning systems for dwelling units are capable of protecting about half of the occupants in potentially fatal fires Victims are often intimate wi...

Страница 10: ...ng an early warning of a fire they are not a substitute for an insurance policy Home owners and renters should have adequate insur ance to protect their lives and property 8 GOOD SAFETY HABITS DEVELOP...

Страница 11: ...uables In leaving don t open any inside door without first feeling its surface If hot or if you see smoke seeping through cracks don t open that door Instead use your alternate exit If the inside of t...

Страница 12: ...e areas for increased protection The additional areas include the basement bedrooms dining room furnace room utility room and hallways not protected by the required smoke alarms The installation of th...

Страница 13: ...eviewing this manual you feel that your smoke alarm is defective in any way do not tamper with the unit Return it for servicing to KIDDE Safety 1016 Corporate Park Dr Mebane NC 27302 1 800 880 6788 Se...

Страница 14: ...LARM OR UNDER THE TERMS OF THIS LIMITED WARRANTY SHALL NOT IN ANY CASE EXCEED THE COST OF REPLACEMENT OF SMOKE ALARM AND IN NO CASE SHALL KIDDE SAFETY OR ANY OF ITS PARENT OR SUBSIDIARY CORPORATIONS B...