11. Operation and Testing

operation

The alarm is operating once it is activated and testing is complete. When products of combustion (smoke) are 
sensed, the unit sounds a loud alarm with a voice message. See Sections 1 and 2 for alarm signal descriptions. 

teStinG

Test your alarm weekly by pressing and releasing the test button quickly. A quick beep will confirm the button 
has been pushed followed by voice prompts that will inform you of the upcoming test sequence. See Other 
Alarm Visual and Audible Indicators table. 

The alarm and voice (and any interconnected units) will sound if the electronic circuitry, horn, speaker, and 
battery are working. If the alarm or voice does not sound, or gives erratic or low volume sound, the unit must 
be replaced. See Permanently Disable Alarm / Discharge Battery section to determine how to prepare the 
unit for shipment or disposal.

 WarninG:  dUe to tHe LoUdneSS oF tHe aLarM, aLWayS Stand aboUt 0.7 M (2.5 Ft) aWay 

FroM tHe Unit or USe ear protection WHen teStinG.

 WarninG:  do not USe an open FLaMe to teSt yoUr aLarM, yoU coULd daMaGe tHe 

aLarM or iGnite coMbUStibLe MateriaLS and Start a StrUctUre Fire.

SMoke aLarM MeMory

If a unit experiences a smoke alarm event, then the condition clears and the unit stops alarming, the unit 
will give a visual (LED) indicator that a previous alarm has occurred within the last hour. See the Other Alarm 
Visual and Audible Indicators table.

Содержание P4010ACS-WCA

Страница 1: ...0ACS WCA Model P4010LACS WCA Safety Light WireLESS Interconnect You do NOT need a home wi fi system to use these units Multiple wireless units create their own independent wireless alarm network 120 V...

Страница 2: ...ould never play with the unit Your Kidde Smoke Alarm was designed for use in a residential environment It is not designed for use in a recreational vehicle RV or boat Note Please take a few minutes to...

Страница 3: ...cations For Smoke Alarms 10 8 Locations To Avoid 12 9 Activation And Wireless Alarm Network 12 9 1 Setting Up A Wireless Alarm Network 13 9 2 Adding Another Device to an Existing Wireless Alarm Networ...

Страница 4: ...If the inside of the door is cool place your shoulder against it open it slightly and be ready to slam it shut if heat and smoke rush in If the escape route requires you to go through smoke stay clos...

Страница 5: ...of Carbon Monoxide CO at high concentrations which can kill you 1 Immediately move to fresh air outdoors or by an open door window Do a head count to check that all persons are accounted for Do not r...

Страница 6: ...0 sec After button push Smoke previously detected only on the initiating alarm unit Push test button to clear Alarm Memory NOTE standard test sequence will follow Push release button again to cancel t...

Страница 7: ...of Unit Life Hush Mode after push release Test Hush button during End of Life Voice Temporarily Silenced End of Unit Life chirps silenced for 24 hrs 7 days after End of Unit Life chirps begin the chi...

Страница 8: ...10 year battery and unit life Product Features and Specifications Temperature Operating Range 4 4 C 40 F to 37 8 C 100 F Humidity Operating range up to 95 RH non condensing Audible Alarm 85 dB at 10...

Страница 9: ...nsing alarms may detect invisible fire particles associated with fast flaming fires sooner than photoelectric alarms Photoelectric sensing alarms may detect visible fire particles associated with slow...

Страница 10: ...smoke alarms and smoke detectors on tray shaped ceilings 4 10cm 4 10cm 12 30 5cm 12 30 5cm ANYWHERE ALONG THIS BOLD SURFACE Locations permitted for smoke alarms and smoke detectors on tray shaped cei...

Страница 11: ...MA 02269 Mobile Home Installation Modern mobile homes have been designed and built to be energy efficient Install smoke alarms as recommended on the previous page In older mobile homes that are not w...

Страница 12: ...condensing Moisture or steam can cause nuisance alarms In insect infested areas Smokealarmsshouldnotbeinstalledwithin0 9m 3ft ofthedoortoabathroomcontainingatuborshower forced air supply ducts used fo...

Страница 13: ...position on ALL devices using the white tool included with the Quick Start Guide Once powered the light rings will glow red and voice message will announce Ready to connect Follow Quick Start instruct...

Страница 14: ...beeps Release button Sonar ping will stop Device will announce that setup is complete and the number of connected devices G Setup complete If all devices flash green and Sonar ping has stopped the de...

Страница 15: ...ress and hold the button on ONE INSTALLED device on your network until you hear two beeps Release button You will hear Searching for other devices Light will pulse green and device will sound a contin...

Страница 16: ...ettings b Conclude reset Light ring will flash green once and then it will pulse red You will hear the words Ready to connect follow quick start instructions Device has been reset See Section 9 1 to b...

Страница 17: ...combination alarm and detector guard have been evaluated and found suitable for that purpose WARNING The alarm cannot be operated from power derived from a square wave modified square wave or modified...

Страница 18: ...e to the alarm failure to operate or a shock hazard Makecertainalarmsarewiredtoacontinuous non switched powerline NOTE Use standard CSA Listed household wire as required by local codes available at al...

Страница 19: ...the following three steps Plug the AC QUICK CONNECTOR into the wiring harness attached to the unit making sure that the locks on the connector snap into place Then push the excess wire back into the...

Страница 20: ...larm interconnect capability When one hardwire or wireless interconnect unit sounds an alarm all other compatible hardwire or wireless interconnected units will also alarm This model is not designed t...

Страница 21: ...cuitry horn speaker and battery are working If the alarm or voice does not sound or gives erratic or low volume sound the unit must be replaced See Permanently Disable Alarm Discharge Battery section...

Страница 22: ...at night Moving the unit to a different location might allow the unit to determine a valid Night Day cycle WARNING REPLACE UNIT AS SOON AS POSSIBLE WHEN IN END OF UNIT LIFE OR LOW BATTERY MODE 12 Rec...

Страница 23: ...nd during alarm Depending on unit locations and the location of the source of smoke it is possible to have more than one initiating unit If you suspect a nuisance alarm situation you can use this feat...

Страница 24: ...idity or temperatures may reduce battery life WARNING NO SERVICEABLE PARTS INCLUDED DO NOT ATTEMPT TO OPEN THE ALARM FOR ANY REASON Do not try to repair the alarm yourself Low Battery This alarm is eq...

Страница 25: ...onger function Oncethealarmbatteryhasbeendischarged thealarmcannotbemountedontothemountingplate orreactivated To Permanently Disable Alarm Discharge Battery Rotate the alarm counterclockwise to remove...

Страница 26: ...damage the alarm If the alarm is in Fault mode and the Red LED is blinking a fault code of 10 or 14 flashes after a Test Hush button push the alarm may be in need of cleaning After cleaning press the...

Страница 27: ...chain ladder Have a family meeting and discuss your escape plan showing everyone what to do in case of fire and where to meet after they leave the house Ensure that small children hear the alarm and...

Страница 28: ...le The required number of smoke alarms might not provide reliable early warning protection for those areas separated by a door from the areas protected by the required smoke alarms For this reason it...

Страница 29: ...each separate dwelling unit sleeping area within 6 4 m 21 of any door to a sleeping room with the distance measured along a path of travel 3 On every level of a dwelling unit including basements 4 On...

Страница 30: ...is product or for any indirect special incidental or consequential damages or costs or expenses incurred by the consumer or any other user of this product whether due to a breach of contract negligenc...

Отзывы: