1. Information About Carbon Monoxide

Carbon Monoxide PPM Levels

(model 900-0230 with digital display only)

Model 900-0230 is equipped with a digital display that shows levels of

CO (displayed in PPM – parts per million). Learn the difference between

dangerous, high, mid and low levels.

Dangerous Levels: 

When someone is experiencing symptoms of CO poisoning and CO

readings are generally above 100 PPM. Anytime someone is experiencing

the symptoms of CO poisoning this should be treated as an emergency.

See “What to do When the Alarm Sounds” (inside front cover).

High Levels:

Generally above 100 PPM, with no one experiencing symptoms. This

should be treated as an urgent situation. See “What to do When the

Alarm Sounds” (inside front cover).

Mid Levels:

Generally between 50 PPM to 100 PPM. This should be cause for

concern and should not be ignored or dismissed. See “What to do

When the Alarm Sounds” (inside front cover).

Low Levels:

Generally below 50 PPM. Kidde recommends you take action to

eliminate the source of CO. See “What to do When the Alarm Sounds”

(inside front cover).

IMPORTANT: Model 900-0233 does not have a digital display and

does not display carbon monoxide levels in PPM. If the alarm

sounds, it should be treated as a potentially serious condition. 

See

“What to do When the Alarm Sounds” (inside front cover).

Possible Sources of Carbon Monoxide

Inside your home, appliances used for heating and cooking are the most

likely sources of CO. Vehicles running in attached garages can also

produce dangerous levels of CO.

CO can be produced when burning any fossil fuel, such as gasoline,

propane, natural gas, oil and wood.  It can be produced by any fuel-

burning appliance that is malfunctioning, improperly installed, or not

ventilated correctly, such as:

• Automobiles, furnaces, gas ranges/stoves, gas clothes dryers, water

heaters, portable fuel burning space heaters and generators,

fireplaces, wood-burning stoves and certain swimming pool heaters. 

Содержание 900-023

Страница 1: ...d this user s guide which should be saved for future reference and passed on to any subsequent owner Carbon Monoxide Alarm User s Guide 900 0233 and 900 0230 900 0233 900 0230 SINGLE STATION CARBON MO...

Страница 2: ...2 Call your emergency services Fire Department or 911 Never restart the source of a CO problem until it has been corrected Never ignore the sound of the alarm If the alarm is sounding pressing the tes...

Страница 3: ...ke alarm is alarming in a non emergency situation Because your sense of sight smell hearing and touch give you information you can almost instantly judge what action to take if you hear your smoke ala...

Страница 4: ...It may not fully safeguard individuals with specific medical conditions If in doubt consult a medical practitioner Individuals with medical problems may consider using warning devices which provide a...

Страница 5: ...CO poisoning indicate that while victims are aware they are not well they become so disoriented they are unable to save themselves by either exiting the building or calling for assistance Also young...

Страница 6: ...When the Alarm Sounds inside front cover Low Levels Generally below 50 PPM Kidde recommends you take action to eliminate the source of CO See What to do When the Alarm Sounds inside front cover IMPORT...

Страница 7: ...oose from clothes dryers furnaces or water heaters Obstructions in or unconventional vent pipe designs which can amplify the above situations Extended operation of unvented fuel burning devices range...

Страница 8: ...tional life You must test your CO alarm weekly because it could fail to operate at any time If your CO alarm fails to test properly or if its self diagnostic test reveals a malfunction immediately hav...

Страница 9: ...ower up this alarm will beep two times every 30 seconds to indicate that it is time to replace the alarm Replace the alarm immediately It will not detect CO in this condition To help identify the date...

Страница 10: ...m at eye level allows for optimum monitoring of the digital display 3 Installation Locations Recommended Locations Temperature Operating Range 4 4 C 40 F to 37 8 C 100 F Humidity Operating range 10 95...

Страница 11: ...ing or cooking appliances Kidde recommends 15 ft to prevent nuisance alarms Do not install near vents flues chimneys or any forced unforced air ventilation openings Do not install near ceiling fans do...

Страница 12: ...lacing the batteries use one of the following approved brands Duracell MN1500 or MX1500 Energizer E91 Gold Peak 15A Golden Power GLR6A These batteries can be purchased where you bought the alarm or at...

Страница 13: ...il the screw heads are protruding approximately 1 8 from the wall If mounting in a plasterboard or drywall drill a 3 16 hole in the wall and use the plastic anchors provided 3 Hook the CO alarm over t...

Страница 14: ...error condition Error Red LED constantly on Constant alarm Very low battery or unit malfunction Replace battery If condition continues unit has malfunctioned Replace immediately Unit will not respond...

Страница 15: ...nly Steady 0 displayed dot flashing every 5 seconds Green LED flashes every 30 secs None Normal DC operation with good batteries sensing no CO None Lb flashes alternately with any number Red LED flash...

Страница 16: ...may start out as low level leaks but could develop into CO concentrations that may become harmful If this happens the CO alarm will detect the dangerous level and alarm notifying you and others of the...

Страница 17: ...or for CO Note You do not need to press the Test button to take a CO reading Maintenance Tips To keep your alarm in good working order you must follow these steps Test the alarm once a week by pressin...

Страница 18: ...or loss of use of this product or for any indirect special incidental or consequential damages or costs or expenses incurred by the consumer or any other user of this product whether due to a breach o...

Страница 19: ...for a particular purpose are limited in duration to the above warranty period In no event shall the Manufacturer be liable for loss of use of this product or for any indirect special incidental or con...

Отзывы: