Recommended Installation Locations

CO alarms should be mounted in or

near bedrooms and living areas. It is

recommended that you install a

Kidde CO alarm on each level of

your home.

When choosing your installation

locations, make sure you can hear

the alarm from all sleeping areas. If

you install only one CO alarm in your home, install it near bedrooms,

not in the basement or furnace room.

• When wall mounting, place out of reach of children. Under no

circumstances should children be allowed to handle the CO alarm.

• Placing the alarm at eye level allows for optimum monitoring of the

digital display.

3. Installation Locations

 

 

 

Recommended Locations

Temperature:

Operating Range: 4.4°C (40°F) to 37.8°C (100°F)

Humidity: 

Operating range: 10-95% non-condensing

Audible Alarm:

85+ dB at 10’ @ 3.4±0.5 KHz pulsing alarm

Sensor:

Electrochemical

Power:

3-AA Batteries

Accuracy of Digital Display: (Model 900-0230 Only)

30-999 PPM +/-30% when measured in conditions of 26.7°C (80°F) +/-

5.6°C (10°F), atmospheric pr/- 10% and 40% +/- 3% relative

humidity. Display readings may vary slightly depending on changes in the

ambient condition (temperature, humidity) and the condition of the sensor.

Alarm Response Times:

70 PPM = 60-240 min., 150 PPM = 10-50 min., 400 PPM = 4-15 min.

2. Product Features and Specifications

Содержание 900-023

Страница 1: ...d this user s guide which should be saved for future reference and passed on to any subsequent owner Carbon Monoxide Alarm User s Guide 900 0233 and 900 0230 900 0233 900 0230 SINGLE STATION CARBON MO...

Страница 2: ...2 Call your emergency services Fire Department or 911 Never restart the source of a CO problem until it has been corrected Never ignore the sound of the alarm If the alarm is sounding pressing the tes...

Страница 3: ...ke alarm is alarming in a non emergency situation Because your sense of sight smell hearing and touch give you information you can almost instantly judge what action to take if you hear your smoke ala...

Страница 4: ...It may not fully safeguard individuals with specific medical conditions If in doubt consult a medical practitioner Individuals with medical problems may consider using warning devices which provide a...

Страница 5: ...CO poisoning indicate that while victims are aware they are not well they become so disoriented they are unable to save themselves by either exiting the building or calling for assistance Also young...

Страница 6: ...When the Alarm Sounds inside front cover Low Levels Generally below 50 PPM Kidde recommends you take action to eliminate the source of CO See What to do When the Alarm Sounds inside front cover IMPORT...

Страница 7: ...oose from clothes dryers furnaces or water heaters Obstructions in or unconventional vent pipe designs which can amplify the above situations Extended operation of unvented fuel burning devices range...

Страница 8: ...tional life You must test your CO alarm weekly because it could fail to operate at any time If your CO alarm fails to test properly or if its self diagnostic test reveals a malfunction immediately hav...

Страница 9: ...ower up this alarm will beep two times every 30 seconds to indicate that it is time to replace the alarm Replace the alarm immediately It will not detect CO in this condition To help identify the date...

Страница 10: ...m at eye level allows for optimum monitoring of the digital display 3 Installation Locations Recommended Locations Temperature Operating Range 4 4 C 40 F to 37 8 C 100 F Humidity Operating range 10 95...

Страница 11: ...ing or cooking appliances Kidde recommends 15 ft to prevent nuisance alarms Do not install near vents flues chimneys or any forced unforced air ventilation openings Do not install near ceiling fans do...

Страница 12: ...lacing the batteries use one of the following approved brands Duracell MN1500 or MX1500 Energizer E91 Gold Peak 15A Golden Power GLR6A These batteries can be purchased where you bought the alarm or at...

Страница 13: ...il the screw heads are protruding approximately 1 8 from the wall If mounting in a plasterboard or drywall drill a 3 16 hole in the wall and use the plastic anchors provided 3 Hook the CO alarm over t...

Страница 14: ...error condition Error Red LED constantly on Constant alarm Very low battery or unit malfunction Replace battery If condition continues unit has malfunctioned Replace immediately Unit will not respond...

Страница 15: ...nly Steady 0 displayed dot flashing every 5 seconds Green LED flashes every 30 secs None Normal DC operation with good batteries sensing no CO None Lb flashes alternately with any number Red LED flash...

Страница 16: ...may start out as low level leaks but could develop into CO concentrations that may become harmful If this happens the CO alarm will detect the dangerous level and alarm notifying you and others of the...

Страница 17: ...or for CO Note You do not need to press the Test button to take a CO reading Maintenance Tips To keep your alarm in good working order you must follow these steps Test the alarm once a week by pressin...

Страница 18: ...or loss of use of this product or for any indirect special incidental or consequential damages or costs or expenses incurred by the consumer or any other user of this product whether due to a breach o...

Страница 19: ...for a particular purpose are limited in duration to the above warranty period In no event shall the Manufacturer be liable for loss of use of this product or for any indirect special incidental or con...

Отзывы: