Technical Information
23
Product Specifications
Power:
230V AC units: 50 Hz, Current 50 mA max.
Sensor:
CO sensor calibrated at 150 ppm (±25 ppm).
Temperature:
Operating range: 40˚F (4.4˚C) to 100˚F (37.8˚C).
Mounting:
Accessories supplied for wall mount or direct plug
applications.
Alarm:
85+ dB at 10’ @ 3.4 ± 0.5 KHz pulsing alarm. In alarm
condition you will hear a repeating pattern of quick
beeps.
LED Operation:
Red LED flashes in unison with alarm sounder during alarm
and fault modes.
Green LED is on constantly while the unit is powered with
230 volts and flashes every 15 seconds while on battery
backup.
Yellow LED flashes when the battery is low and is on
constantly when the alarm malfunctions.
Battery Backup:
A 9 volt battery is needed. If battery is low or missing while
the unit is plugged into a 230V outlet, the unit will beep in uni-
son with the red LED flashing and the yellow LED will flash
independently every 15 seconds.
Unit Malfunction:
Alarm will beep every 30 seconds and the yellow LED will be
lit continuously
Test/Reset Button:
Test button verifies proper unit operation and resets the unit
in the event of a CO alarm.
Peak Level Memory Button:
When pressed, the alarm will sound 8 beeps if a CO level
above 50ppm has been detected since unit was powered up
or since unit was reset with test button. Reading will be stored
in memory as long as unit is not reset or unplugged.
Size:
15.2 cm (6”)L x 3.75”W x 1.8”H. Wt. 1 lb.
Warranty:
Five-year warranty from date of purchase against defects in
material and workmanship.