manualshive.com logo in svg
background image

1

P/N: 2030-7201-00

SMOKE ALARM

Photoelectric Smoke Alarm with Hush  
User Guide

Model:  2030-DSR

 

• 

Smoke Alarm Hush

 

Control

• 

Small Structure Design

1008

102.0012

EN14604:2005/AC:2008

21

EN 14604:2005

Содержание 2030-DSR

Страница 1: ...1 P N 2030 7201 00 SMOKE ALARM Photoelectric Smoke Alarm with Hush User Guide Model 2030 DSR Smoke Alarm Hush Control Small Structure Design 1008 102 0012 EN14604 2005 AC 2008 21 EN 14604 2005...

Страница 2: ...on to any subsequent owner IMPORTANT Additional markings can be found on the back of the unit ENVIRONMENTAL PROTECTION Waste electrical products or equivalent should not be disposed of with household...

Страница 3: ...Alarm Visual and Audible Indicators 6 4 Troubleshooting Guide 7 5 Limitations of Smoke Alarms 8 6 Recommended Locations for Smoke Alarms 9 7 Locations To Avoid 13 8 Installation Instructions 14 9 Oper...

Страница 4: ...surface If hot or if you see smoke seeping through cracks don t open that door Instead use your alternate exit If the inside of the door is cool place your shoulder against it open it slightly and be...

Страница 5: ...ode See Troubleshooting Guide To help track the life of your alarm write the installation date in the space provided on the side of the alarm Product Features and Specifications Temperature Operating...

Страница 6: ...beep pattern Button press sound 3 long beeps Perform button press once a week to verify proper alarm operation Smoke Alarm Memory unit has experienced a smoke alarm event within the last hour Red LED...

Страница 7: ...dispose unit and replace as soon as possible Memory Fault Red LED blinks 3 times every 30 sec Chirp every 30 sec Contact Product Support MCU Failure None Constant tone Replace alarm Contact Product Su...

Страница 8: ...may not be effective to protect against fire For instance a smoking in bed b leaving children home alone c cleaning with flammable liquids such as petrol A battery powered alarm must have a battery o...

Страница 9: ...m in the dwelling for example an office library or lounge other than a toilet bathroom or shower room Locate additional alarms to monitor any stairway as stairways act like chimneys for smoke and heat...

Страница 10: ...beam is less than 600 mm in depth install an alarm on the underside of the beam Otherwise install an alarm both sides of the beam but no closer than twice the depth of the beam or 500 mm whichever is...

Страница 11: ...o CO or Smoke Alarms in Garage Not within 1 m of appliances see Locations to Avoid section Bedroom Bedroom Bedroom Loft Conversion Bedroom Bedroom Bathroom Bathroom Garage Dining Kitchen Living Room L...

Страница 12: ...12 Figure 6 C Figure 6 D Figure 6 B ANYWHERE ALONG THIS BOLD SURFACE 300 mm Figure 6 A MULTI FLOOR PLAN 600mm 600 mm...

Страница 13: ...en in Figures 6 A 6 C and 6 D In an area where the temperature may fall below 0 C or rise above 40 C such as garages and unfinished attics Do not install smoke alarms in dusty areas Dust particles may...

Страница 14: ...ed tested and certified for wall if applicable and ceiling surface mount only Without agency research we have no fire test data to support that alarms will perform as required when installed in a rece...

Страница 15: ...chors CAUTION If the battery compartment is empty the unit will not attach to the mounting bracket Please installing the battery at first Alignment marks are provided on the edge of the mounting brack...

Страница 16: ...n the base is allowed to engage the mounting bracket Rotate the alarm onto the mounting bracket until you hear the tamper resist tab snap into place locking the alarm on the mounting bracket Using the...

Страница 17: ...ctronic circuitry horn and battery are working If no alarm sounds the unit has a defective battery or other failure Test the alarm weekly to ensure proper operation Never use an open flame or combusti...

Страница 18: ...mediately for approximately 9 minutes and the red LED will blink every 2 seconds This indicates that the alarm is in a temporarily desensitized condition The smoke alarm will automatically reset after...

Страница 19: ...tion of the OFF arrow on the cover The Smoke Alarm is powered by a 9V battery A fresh battery should last for one year under normal operating conditions Low Battery This alarm has a low battery monito...

Страница 20: ...al the vents and interfere with the sensor s ability to detect smoke Never attempt to disassemble the unit to clean inside This action will void your warranty WARNING Reinstall the Alarm as soon as po...

Страница 21: ...or chain ladder Have a family meeting and discuss your escape plan showing everyone what to do in case of fire and where to meet after they leave the house Ensure that small children hear the alarm a...

Страница 22: ...ommended that the householder consider the use of additional smoke alarms for those areas for increased protection The additional areas include the basement bedrooms dining room utility room and hallw...

Страница 23: ...t Kidde Safety Europe Ltd Ash House Littleton Road Ashford TW15 1TZ UK This warranty shall not apply to the smoke alarm if it has been damaged modified abused or altered after the date of purchase or...

Страница 24: ...Corporate Park Drive Mebane NC 27302 USA Telephone 0800 917 0722 www kiddesafetyeurope co uk Made in China EU Authorised Representative Carrier Fire Security B V Kelvinstraat 7 6003 DH Weert NL 2021 C...