7. LIMITATIONS OF SMOKE ALARMS

WARNING: PLEASE READ CAREFULLY AND THOROUGHLY

• NFPA 72 states: Life safety from fire in residential occupancies is based primari-

ly on early notification to occupants of the need to escape, followed by the
appropriate egress actions by those occupants. Fire warning systems for
dwelling units are capable of protecting about half of the occupants in poten-
tially fatal fires.  Victims are often intimate with the fire, too old or young, or
physically or mentally impaired such that they cannot escape even when
warned early enough that escape should be possible. For these people, other
strategies such as protection-in-place or assisted escape or rescue are neces-
sary.

• Smoke alarms are devices that can provide early warning of possible fires at a

reasonable cost; however, alarms have sensing limitations. Ionization sensing
alarms may detect invisible fire particles (associated with fast flaming fires)
sooner than photoelectric alarms. Photoelectric sensing alarms may detect visi-
ble fire particles (associated with slow smoldering fires) sooner than ionization
alarms. Home fires develop in different ways and are often unpredictable. For
maximum protection, Kidde recommends that both Ionization and
Photoelectric alarms be installed.

• A battery powered alarm must have a battery of the specified type, in good

condition and installed properly.  

• A.C. powered alarms will not operate if the A.C. power has been cut off, such

as by an electrical fire or an open fuse.

• Smoke alarms must be tested regularly to make sure the batteries and the

alarm circuits are in good operating condition.

• Smoke alarms cannot provide an alarm if smoke does not reach the alarm.

Therefore, smoke alarms may not sense fires starting in chimneys, walls, on
roofs, on the other side of a closed door or on a different floor.

• If the alarm is located outside the bedroom or on a different floor, it may not

wake up a sound sleeper.

• The use of alcohol or drugs may also impair one’s ability to hear the smoke

alarm.  For maximum protection, a smoke alarm should be installed in each
sleeping area on every level of a home.

• Although smoke alarms can help save lives by providing an early warning of a

fire, they are not a substitute for an insurance policy.  Home owners and
renters should have adequate insurance to protect their lives and property.

 

Содержание 1296

Страница 1: ...specified manufacturer s interconnect system or connection with non specified equipment from another manufacturer into an existing Kidde system could result in nuisance alarming failure to alarm or da...

Страница 2: ...THIS MANUAL NEAR THE ALARM FOR FUTURE REFERENCE CONTENTS OF THIS MANUAL 1 RECOMMENDED LOCATIONS FOR SMOKE ALARMS 2 LOCATIONS TO AVOID 3 INSTALLATION INSTRUCTIONS 4 OPERATION AND TESTING 5 NUISANCE AL...

Страница 3: ...details see MOBILE HOME INSTAL LATION below When mounting an alarm on the ceiling locate it at a minimum of 4 10 cm from the side wall see Figure 1 When mounting the alarm on the wall use an inside w...

Страница 4: ...ional protection see SINGLE FLOOR PLAN in Figure 2 WARNING TEST YOUR SMOKE ALARM OPERATION AFTER R V OR MOBILE HOME VEHICLE HAS BEEN IN STORAGE BEFORE EACH TRIP AND AT LEAST ONCE A WEEK DURING USE 2 L...

Страница 5: ...ave inverter These types of inverters are sometimes used to supply power to the structure in off grid installations such as solar or wind derived power sources These power sources produce high peak vo...

Страница 6: ...nnected with other Kidde alarms and accessories as well as specified brands and models of interconnect compatible alarms Connection of Kidde products to a non specified manufac turer s interconnect sy...

Страница 7: ...ring the A C QUICK CONNECT harness as described in the WIRING INSTRUCTIONS attach the trim ring to the electrical box see Figure 5 3 Use a screwdriver to punch out only the pair of holes in the trim r...

Страница 8: ...m A C power TAMPER RESIST LOCKING PIN To make your smoke alarm tamper resistant a locking pin has been provided with your alarm Using this pin will help deter children and others from removing the ala...

Страница 9: ...en the unit senses products of combustion and goes into alarm mode the red LED will flash rapidly one flash per second The rapid flashing LED and temporal alarm will continue until the air is cleared...

Страница 10: ...ing instructions outlined in section 6 of the manual to clean your alarm To check for proper smoke entry into the alarm Kidde recommends using aerosol smoke manufactured by Home Safeguard Industries F...

Страница 11: ...he alarm see Section 3 Figure 6 BATTERY INSTALLATION AND REMOVAL To replace or install the batteries you must first remove the alarm from the trim ring by following the ALARM REMOVAL instruc tions at...

Страница 12: ...BER OPERATION THIS ALARM WILL CHIRP IF ABNORMAL OPERATION OF THE SMOKE SENSING CHAMBER IS DETECT ED THIS CHIRP WILL OCCUR APPROXIMATELY 10 SECONDS AFTER THE RED LED FLASH REPLACE THE ALARM IF THIS CON...

Страница 13: ...ooner than ionization alarms Home fires develop in different ways and are often unpredictable For maximum protection Kidde recommends that both Ionization and Photoelectric alarms be installed A batte...

Страница 14: ...y level of the home and in the kitchen basement and garage Know how to use a fire extinguisher prior to an emergency Current studies have shown smoke alarms may not awaken all sleeping indi viduals an...

Страница 15: ...iple station smoke alarms shall be installed as follows 1 In all sleeping rooms Exception Smoke alarms shall not be required in sleeping rooms in existing one and two family dwelling units 2 Outside o...

Страница 16: ...all rooms and areas of the household as follows A smoke alarm installed in each separate sleeping area in the vicinity of but outside of the bed rooms and heat or smoke detectors in the living rooms d...

Страница 17: ...E ALARM OR UNDER THE TERMS OF THIS LIMITED WARRANTY SHALL NOT IN ANY CASE EXCEED THE COST OF REPLACE MENT OF SMOKE ALARM AND IN NO CASE SHALL KIDDE SAFETY OR ANY OF ITS PAR ENT OR SUBSIDIARY CORPORATI...

Отзывы: