manualshive.com logo in svg
background image

Manual P/N 2540-7205-02

User Guide for Model 10SCO

• Battery Operation: 9V Battery

• 2-LED Display

• Front Load Battery

• Peak Level Memory

• Hush®

• Voice Message System

For your convenience, write down the following information. If you call

our consumer hotline, these are the first questions you will be asked:

Alarm Model Number

(located on back of the alarm):

Date of Manufacture

(located on back of the alarm):

Date of Purchase:

Where Purchased:

ATTENTION: Please take a few minutes to thoroughly read this user
guide which should be saved for future reference and passed on to any
subsequent owner.

Combination

Photoelectric
Smoke and Carbon
Monoxide Alarm

EN50291-1 : 2010

EN14604:2005

o.

License N KM602617

2540-7205-02_10SCO(KN-COPE-D).qxd:_  2014.3.21  10:48 AM  Page 1

Содержание 10SCO

Страница 1: ...tions you will be asked Alarm Model Number located on back of the alarm Date of Manufacture located on back of the alarm Date of Purchase Where Purchased ATTENTION Please take a few minutes to thoroug...

Страница 2: ...uel emergencies call HETAS 0845 634 5626 or for oil based emergencies call Oftec 0845 658 5080 Never restart the source of the CO problem until it has been corrected Never ignore the sound of the alar...

Страница 3: ...uantities of combustible particles are generated from spills or when broiling Using the fan on a range hood which vents to the outside non recirculating type will also help remove these combustible pr...

Страница 4: ...to protect against fire For example Smoking in bed Leaving children unsupervised Cleaning with flammable liquids such as gaso line Fires where the victim is intimate with a flaming initiated fire for...

Страница 5: ...11 Operating Instructions 14 CO Alarm Response Time 15 Alarm Removal 16 Battery Replacement 17 General Alarm Maintenance 18 Carbon Monoxide Safety Information General CO Information 19 Possible Source...

Страница 6: ...on monoxide from any source of combustion in a residential environment It is not designed for use in a caravan or boat This apparatus is NOT a substitute for maintenance of fuel burning appliances and...

Страница 7: ...FRONT Test Reset Hush Button Green Red LED Light Emitting Diode Battery Compartment Alarm Sounder 2 Product View Voice Speaker 2540 7205 02_10SCO KN COPE D qxd _ 2014 3 21 10 48 AM Page...

Страница 8: ...BACK 3 Product View Mounting Bracket Tamper Resist Latch Battery Door Tamper Resist Slide 2540 7205 02_10SCO KN COPE D qxd _ 2014 3 21 10 48 AM Page...

Страница 9: ...Y This alarm has a low battery pre warning The red LED will flash every 60 seconds for a period of 28 days Following this pre warning when the battery is low and needs replacing the red LED will flash...

Страница 10: ...g bracket designed for easy orientation of the unit Green and red LED lights that indicate normal operation and alarm status o Green Light The green LED will be lit continuously or flash every 30 seco...

Страница 11: ...in place or assisted escape or rescue are necessary Smoke alarms are devices that can provide early warning of possible fires at a reasonable cost however alarms have sensing limitations Ionisation s...

Страница 12: ...monitors the air for the presence of CO It will alarm when there are high levels of CO present and when there are low levels of CO present over a longer period of time When a CO condition matches eith...

Страница 13: ...ore than 30 ft 9 1m long If you have only one alarm ensure it is placed in the hallway outside of the main sleeping area or in the main bedroom Verify the alarm can be heard in all sleeping areas Loca...

Страница 14: ...Recommended Installation Instructions and figure 1 In older mobile homes that are not well insulated extreme heat or cold can be transferred from the outside to the inside through poorly insulated wal...

Страница 15: ...alarm on the mounting bracket and rotate the alarm in the direction of the ON arrow on the cover until the alarm ratchets into place this ratcheting function B Where Not to Install Do not install in g...

Страница 16: ...unit when testing The test reset button has four purposes It tests the unit s electronics resets the CO alarm activates the HUSH feature and activates the Peak Level Memory Feature After installation...

Страница 17: ...OUND A CONTINUOUS ALARM CAUTION BEFORE USING THE ALARM HUSH FEATURE IDENTIFY THE SOURCE OF THE SMOKE AND BE CERTAIN A SAFE CONDITION EXISTS Reset Feature If the Smoke CO Alarm is sounding a CO alarm p...

Страница 18: ...smoke CO alarm tamper resistant two tamper resist features have been provided The first is used to discourage removal of the alarm while the second is for the battery To activate the mounting bracket...

Страница 19: ...e the unit from the trim and locate the small cut out in the middle of the product label on the back of the unit With a small screwdriver or similar tool slide the switch towards the top of the label...

Страница 20: ...ervice performed NOTE Before activating the battery carrier tamper resist feature make sure a fresh battery is installed in the unit and that the battery carrier is properly closed If the battery carr...

Страница 21: ...EALED AND THE COVER IS NOT REMOVABLE Note If battery carrier tamper resist feature has been activated it will need to be deactivated in order to change the battery Refer to section 3 Battery Carrier T...

Страница 22: ...the trouble chirp for two days giving you exrtra time to replace the unit at a more convenient time To activate press the test reset button While in the End of Life Hush mode will still detect CO and...

Страница 23: ...any of the following Staining or stripping wood floors or furniture Painting Wall papering Using adhesives Storing the unit in a plastic bag during any of the above projects will protect the sensors f...

Страница 24: ...ed by outdoor ambient conditions such as Wind direction and or velocity including high gusts of wind heavy air in the vent pipes cold humid air with extended periods between cycles negative pressure d...

Страница 25: ...ARBON MONOXIDE POISONING and should be discussed with ALL members of the household The above levels of exposure relate to healthy adults Levels differ for those at high risk Exposure to high levels of...

Страница 26: ...attern voice message warning and to leave the home using their escape plan when it s heard Know how to do Stop Drop and Roll if clothes catch on fire and how to crawl low under smoke Install and maint...

Страница 27: ...o the above warranty period In no event shall the Manufacturer be liable for loss of use of this product or for any indirect special incidental or consequential damages or costs or expenses incurred b...

Страница 28: ...ce please call our toll free Consumer Hotline at 0800 917 0722 Damage from neglect abuse or failure to adhere to any of the enclosed instructions will result in ter mination of the warranty and the un...

Страница 29: ...RE INFORMATION Call our Consumer Hotline at 0800 917 0722 or contact us at our website at www kiddesafetyeurope co uk Kidde Safety Europe Ltd Mathisen Way Colnbrook Berkshire SL3 0HB Made in China 254...

Отзывы: