background image

GSM Smoke Detector

User Manual

Summary of Contents for FS2SD

Page 1: ...GSM Smoke Detector User Manual ...

Page 2: ...se contrary to the intended use The FS2SD photoelectric sensor is effective at detecting slow smoldering fires that burn for hours before a flame develops as well as violent fires that quickly consume flammable materials and spread rapidly The smoke detector is equipped with a GSM communication module that communi cates with the cloud in Poland Data transmission takes place via the mobile telepho ...

Page 3: ...ars LED diode light signal approximately every 53 seconds to confirm that the device is powered Alarm module low battery warning sound signal beep approximately every 53 seconds when the battery level is low Pausing an alarm mute mode muting the alarm sound signal by pressing and holding the test button for 3 seconds when a non smoke gas e g steam triggers a false alarm In this mode the red LED di...

Page 4: ...e flames or gas This smoke detector is designed to give an audible warning of a developing fire In the event of violent fires involving explosions and oth ers smoke may not reach the detector quickly enough to allow for safe evacuation The smoke detector does not guarantee 100 protection of life health or property against fire Smoke alarms are not a substitute for your insurance benefits The senso...

Page 5: ...he danger Read Chapter 4 LOCATIONS TO AVOID one floor one sleeping area dining room living room kitchen sleeping room sleeping room sleeping room one floor more than one sleeping area TV room sleeping room dining room kitchen living room sleeping room sleeping room GB basement living room kitchen sleeping room sleeping room hall Smoke detectors for limited protection Additional smoke detectors for...

Page 6: ...ceiling at a distance of less than 300 mm 0 3 m from the edge of the wall In places with a lot of insects After getting inside the device small insects may affect the perfor mance of the device In very dusty or dirty places Dirt and dust can accumulate and reduce the performance of your device At a distance of 300 mm 0 3 m from lighting fixtures or room corners In places where it would be dangerou...

Page 7: ...ion Do not over tighten the screws as this will distort the mounting bracket This element should be firmly attached to the selected surface Line up the short marking line on the sen sor housing with the mounting bracket then rotate the sensor clockwise until the line on the sensor aligns with the long mar king line on the mounting bracket To prevent possible tampering insert the security pins into...

Page 8: ... This means that the smoke detector is in false alarm control mode If the smoke detector does not go into false alarm mode and continues to emit loud sound signal or if it initially goes into false alarm control mode and then goes off an alarm smoke is too intense and a dangerous situation may occur take emer gency action 8 SMOKE DETECTOR TESTING WARNING Test each installed smoke detector to make ...

Page 9: ...ork properly Clean the smoke detector at least once a month or depending on the environmental conditions in which it is installed Gently vacuum the out side of the smoke detector with a soft vacuum cleaner brush After maintenance work check the operation of the smoke detector Never use water cleaning agents or solvents as these may damage the device If the smoke sensor becomes contaminated with ex...

Page 10: ...flashes and the alarm beeps once every 53 seconds Low battery REPLACE SMOKE DETECTOR IMMEDIATELY Red LED flashes and smoke detector beeps twice every 53 seconds Clean alarm device OR REPLACE OR REPAIR The smoke detector emits false alarms intermittently 1 Clean the device see chapter 9 MAINTENANCE AND CLEANING 2 Move the smoke detector to another location See Chapter 3 WHERE TO PLACE THE SMOKE DET...

Page 11: ...Y Producer Ferguson Sp z o o ul Dworska 1 61 619 Poznań Name FS2SD GSM Device type Smoke detector The above mentioned product complies with Directive 2014 53 EU of the European Parliament and of the Council of 16 April 2014 on the harmonization of the laws of the Member States relating to the making available on the market of radio equipment and repealing Directive 1999 5 EC Full Declaration of Co...

Page 12: ...produced in PRC for Ferguson sp z o o ul Dworska 1 61 619 Poznań Poland www ferguson digital eu ...

Reviews: