Spark-free protection.
Ÿ
Reverse polarity solar and battery connection.
Ÿ
Against reverse current from battery to solar panel at night.
Ÿ
Over temperature protection with charging current de-rate.
Ÿ
Transient overvoltage protection, a varistor or transient voltage suppressor (TVS) at the
solar input and battery output against surge voltage.
Ÿ
Safety and EMC compliance
IEC/EN 60335, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5 FCC Class-B
EN61000-4-6, EN61000-4-11, EN61000-3-3, CISPR14-1
SAFETY PROTECTION
MAINTENANCE
Occasionally, clean the case using a damp cloth and mild cleaning agent. Check with
terminals without loose, rusty; If connecting cable is damaged, replace the cable by
qualified person.
SPECIFICATION
Voltages in below table are for 12V use, x 2 for 24V use.
1
Electrical Parameters
1-1
Rated solar panel amps
30/40
Max.
AMP
1-2
Normal input Solar cell array voltage
15-22
VDC
1-3
Max. solar cell array voltage (output has no load)
25
Max.
VDC
1-4
The controller lowest operating voltage at solar or battery side
8V
Min
VDC
1-5
Standby current consumption at night
5
Max
mA
0.25
Max.
VDC
1-6
Maximum voltage drop-Solar panel to battery