Страница 1: ...V0 3 SOLAR REGULATOR PWM 12V 30A MANUAL KAPWM30A ...

Страница 2: ...in the vicinity of Lead Acid batteries is dangerous During normal operation batteries generate explosive gases It is important that the battery is operated in a well ventilated area and the Solar Regulator is installed as directed Check the battery manufactures guide for the recommended voltage profile for charging Failure to ensure the selected voltage does not exceed the recommend profile could da...

Страница 3: ...ndoor or outdoor use surface panel mount Ÿ Rubber dust cover for terminal protection Ÿ The battery should be mounted in a well ventilated area and a safe distance from any ignition source NEVER smoke or allow a spark or flame in the vicinity of the battery This may cause the battery to explode Ÿ If battery acid comes in contact with skin or clothing wash immediately with soap and water If acid ente...

Страница 4: ...using the 4 corner screw down points Do this by firstly removing the exiting 4x machine screws and backing plate With the corner screw down points free mark the surface for the mounting points and pre drill your screw holes or simply use a self tapping screw and directly mount the unit Rubber Dust Covers ...

Страница 5: ...the regulator connection marked as battery output Ensure a fuse is installed one the positive cable as close to the battery positive terminal a possible Once Battery is connected to the regulator the correct battery type charge profile can be selected See section Operating Instructions for Battery type selection and LCD operation Step 2 With Solar Panel in shade connect Anderson extension lead from...

Страница 6: ...e solar panel unplugged from the solar connection lead terminate positive and negative solar cables to regulator 3 ensuring bolts are securely tightened With the solar panel out of the sun connect all cables to solar panels ensuring a well sealed termination Note Alway use the correct solar cable as directed by solar panel manufacture and is a minimum of 4mm External Battery Temperature Sensor 1 W...

Страница 7: ...t KAPWM30A Regulator connected with KA Folding Solar Blanket and Power Station r KAPWM30A Regulator connected with KA Folding Solar Blanket and KickAss 120AH AGM Battery KickAss 160W Folding Solar Blanket Note Please connect solar panels to regulator before exposing to direct sun SKU KASB160 SKU KASB160 ...

Страница 8: ... 3 seconds to enter the battery type selection mode The available selections will be shown on the LCD as indicated below Once the correct battery type is selected the regulator will automatically memorize your battery type setting These include Setting Battery Type Max Voltage CRYSTAL Lead Crystal crystalline silicon dioxide 14 7V CALCIUM Calcium Lead acid 14 9V GEL Gel Lead acid 14 1V AGM AGM Lea...

Страница 9: ...etermine if Soft start or Bulk stage is appropriate if the Lithium battery is protected by the BMS the regulator will automatically send a voltage signal periodically to the battery terminal to activate the BMS and bring it out of low voltage protection Soft start When batteries suffer an over discharge the regulator will softly ramp the battery voltage up to 10V before entering the Bulk Stage Bulk...

Страница 10: ...ter this stage when fully charged and will be maintained at a safe level A fully charged Lead Acid battery Crystal GEL AGM WET battery has a voltage of more than 13 8 Volts if the battery voltage drops to 12 8V during the Float Stage the regulator will return to Bulk charge Li ion LiFePO4 and LTO battery have no float mode If a Li ion battery voltage drops to 12 0V after absorption stage it will re...

Страница 11: ...ction Over temperature protection with charging current de rated Transient over voltage protection Safety and EMC compliance IEC EN 60335 EN61000 4 2 EN61000 4 3 EN61000 4 4 EN61000 4 5 FCC Class B EN61000 4 6 EN61000 4 11 EN61000 3 3 CISPR14 1 ...

Страница 12: ...ion stage it will return to Bulk charge if a LIFePO4 battery voltage drops to 13 4V or LTO battery voltage drops to 13 2V after Absorption stage they will return to Bulk charge Voltage x 2 for 24V use LED indications LCD Display LCD Backlight LED Color RED BLUE BLUE BLUE BLUE GREEN WHITE Soft start charging ON FLASH FLASH OFF OFF OFF Normal Display ON Bulk charge charged capacity 25 ON ON ON OFF O...

Страница 13: ...61000 3 3 CISPR14 1 SAFETY PROTECTION MAINTENANCE Occasionally clean the case using a damp cloth and mild cleaning agent Check with terminals without loose rusty If connecting cable is damaged replace the cable by qualified person SPECIFICATION Voltages in below table are for 12V use x 2 for 24V use 1 Electrical Parameters 1 1 Rated solar panel amps 30 40 Max AMP 1 2 Normal input Solar cell array v...