SAFETY PRECAUTIONS
Ÿ
The total current draw from the battery must not exceed 100 Amps. Should the
current draw exceed 100 Amps, the internal BMS will shut down
Ÿ
Ensure that the charger used is compatible with lithium batteries
Ÿ
Do NOT allow any metal objects to come into contact with the battery terminals.
Ÿ
Do NOT try to jumpstart a vehicle with this battery
Ÿ
Do NOT use the battery for cranking/starting applications
Ÿ
Do NOT connect the battery in series to increase the overall voltage
Ÿ
Do NOT connect the battery in parallel to increase the overall amperage
Ÿ
Do NOT allow the battery to sit in a discharged state ≤10.0 V
Ÿ
The battery must be installed away from major heat sources, high voltage, and
avoid exposed sunlight for long periods of time
0 ~ 45°C
14.4 ~ 14.6V
13.5 ~ 13.8V
50A
25 - 40A
Battery Charge Temperature
1
Normal Charge Voltage CV/CC
Standby (Float) Voltage
Maximum Charge Current
Recommended Charge Current
Charging Specification (Only use chargers with lithium profiles as specified)
-20 ~ 60°C
10 ~ 14.6V
100A
280A for 320mS
≤10V
Battery Discharge Temperature
Battery Operating Voltage Range
Maximum Continuous Discharge
Pulse Discharge Current
Discharge Cut-Off Voltage
Standard Discharge Specification
BATTERY SPECIFICATIONS
12.8V
120Ah
≥ 2000 Cycles
Yes
Yes
Nominal Voltage
Nominal Capacity
Cycle Life (DOD – 80% under controlled conditions)
Bluetooth battery montioring app
Optional hardwired remote screen monitoring
120AH LiFePO4 Battery Specifications