background image

1.   To reduce the risk of electric shock, insure 

electricity has been turned off at the circuit 
breaker or fuse box before beginning.

2.   All wiring must be in accordance with the 

National Electrical Code and local electrical 
codes. Electrical installation should be 
performed by a qualified licensed 
electrician.

3.   

WARNING:

 Suitable for use with solid- 

state speed controls.

4.   

WARNING:

 To reduce the risk of personal 

injury, use only the two steel screws (and 
lock washers) provided with the outlet box 
for mounting to the outlet box. Most outlet 
boxes commonly used for the support of 
lighting fixtures are not acceptable for fan 
support and may need to be replaced, 
consult a qualified electrician if in doubt.

5.  The outlet box and support structure must 

be securely mounted and capable of 
reliably supporting a minimum of 50 
pounds. Use only CUL Listed outlet boxes 
marked "FOR FAN SUPPORT".

6.   The fan must be mounted with a minimum 

of 7 feet clearance from the trailing edge of 
the blades to the floor.

7.   Do not operate reversing switch while fan 

blades are in motion. Fan must be turned 
off and blades stopped before reversing 
blade direction.

8.   Avoid placing objects in the path of the 

blades.

9.   To avoid personal injury or damage to the 

fan and other items, be cautious when 
working around or cleaning the fan.

10. Do not use water or detergents when 

cleaning the fan or fan blades. A dry dust 
cloth or lightly dampened cloth will be 
suitable for most cleaning.

11. After making the electrical connections, 

spliced conductors should be turned 
upward and pushed carefully up into outlet 
box. The wires should be spread apart with 
the ground wire and white (common) wire 
to one side with the black (load) wire to the 
other side of the outlet box.

12. Electrical diagrams are reference only. 

Light kits that are not packed with the fan 
must be CUL Listed and marked suitable 
for use with the model fan you are 
installing. Switches must be CUL General 
Use Switches. Refer to the Instructions 
packaged with the light kits and switches 
for proper assembly.

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK 

OR PERSONAL INJURY, MOUNT FAN TO OUTLET 

BOX MARKED "ACCEPTABLE FOR FAN 

SUPPORT".

WARNING

TO REDUCE THE RISK OF PERSONAL INJURY, 

DO NOT BEND THE BLADE BRACKETS (ALSO 

REFERRED TO AS FLANGES) DURING ASSEMBLY 

OR AFTER INSTALLATION. DO NOT INSERT 

OBJECTS IN THE PATH OF THE BLADES.

1

1. SAFETY RULES

Special Notice

This appliance is equipped with a "Wattage 

Limiting Device" required by the United 

States Department of Energy. The device 

has been installed at the factory and can not 

be removed.

Installing Lamps in excess of 190 total watts 

will disable the unit's light fixture. If this 

should happen, you will need to reset the 

lighting fixture by turning the power off to 

the ceiling fan and/or light fixture, 

reinstalling lamps totaling less that 190 

watts and then turning the power back on.

Содержание Bronson

Страница 1: ...chler Lighting 7711 East Pleasant Valley Road P O Box 318010 Cleveland Ohio 44131 8010 Customer Service 866 558 5706 8 30 AM to 5 00 PM EST Monday Friday Instruction Manual Bronson A Kichler Select ceiling fan ...

Страница 2: ...gents when cleaning the fan or fan blades A dry dust cloth or lightly dampened cloth will be suitable for most cleaning 11 After making the electrical connections spliced conductors should be turned upward and pushed carefully up into outlet box The wires should be spread apart with the ground wire and white common wire to one side with the black load wire to the other side of the outlet box 12 El...

Страница 3: ... shade j 40W B8 candelabra bulbs 3 k Part bag contents 1 Mounting hardware wood screw flat washer spring washer star washers 2 wire nuts 3 machine screws 2 washers 2 screws 2 2 Blade attachment hardware screws 14 washers 14 fiber washers 14 3 Safety cable hardware wood screw lock washer flat washer 4 Pull chains and fobs 2 5 Balance Kit Philips screw driver Blade screw driver 11 mm wrench Step lad...

Страница 4: ...mples of different ways to mount the outlet box NOTE If you are installing the ceiling fan on a sloped vaulted ceiling you may need a longer downrod to maintain proper clearance between the tip of the blade and the ceiling A minimum clearance of 12 is suggested for optimal operation NOTE Depending on the location you have selected for installation you may need to purchase and install a Joist Hange...

Страница 5: ...ottom of the ceiling mounting bracket Turn the canopy counterclockwise and remove Fig 5 Step 3 Pass the 120 volt supply wires from the ceiling outlet box through the center of the ceiling mounting bracket Fig 6 Step 4 Attach the ceiling mounting bracket to the outlet box using the screws and washers included with the outlet box Fig 6 Step 5 Remove the hanger ball from the downrod assembly by loose...

Страница 6: ...assembly into position and place the hanger ball into the ceiling mounting bracket Rotate the entire assembly until the Check Tab has dropped into the Registration Slot and seats firmly Fig 10 The entire motor assembly should not rotate left or right when seated properly WARNING Failure to properly seat the Check Tab can damage the ceiling fan during operation Hanger ball Downrod Canopy cover Cano...

Страница 7: ...d off the power at the main circuit panel Follow the steps below to connect the fan to your household wiring Use the wire connecting nuts suppled with your fan Secure the connectors with electrical tape Make sure there are no loose wire strands or connections Step 1 Connect the fan supply black wire and light supply blue wire to the black household supply wire as shown in Figure 12 Step 2 Connect ...

Страница 8: ...opy Canopy cover Screws 9 ATTACHING THE FAN BLADES Fig 14 CAUTION Remove the five rubber shipping blocks attached to the face of the motor These blocks keep the motor from shifting during shipping and MUST be removed during installation Step 1 Attach a blade to a blade bracket using the screws metal washers and fiber washers provided Fig 14 Make sure the blade is straight when set on the blade bra...

Страница 9: ...ach the light kit assembly to the mounting plate with the three screws provided Make use each screw is tight Fig 16 1 Loosen the two screws on the mounting ring attached to the motor shaft and remove and save the third screw Fig 15 2 Place the key holes on the mounting plate over the 2 screws previously loosened from the mounting ring turn mounting plate until it locks in place at the narrow secti...

Страница 10: ...he decorative cap onto the light kit stem Feed the beaded pull chain from the light kit stem through the hold in the decorative nut and thread the decorative nut on securely DO NOT OVER TIGHTEN 4 Attache one pull chain fob to each of the beaded pull chains Fig 17 Note Make sure to leave enough space between the fan pull chain and the bulbs so the chain doesn t rub against any of the bulbs Decorati...

Страница 11: ...ack Slide Switch on the side of the switch housing controls the direction of the blades Forward and Reverse Warm weather Forward counter clockwise A downward airflow creates a cooling effect as shown in Fig 18 This allows you to set your air conditioner on a warmer setting without affecting your comfort Cool weather Reverse clockwise An upward airflow moves warm air off the ceiling area as shown i...

Страница 12: ...ing an optional light kit make sure the screws securing the glassware are tight Make sure the light bulbs are not touching any other component 6 Some fan motors are sensitive to signals from solid state variable speed controls If you have installed this type of control choose and install another type of control 7 Make sure the upper canopy is a short distance from the ceiling It should not touch t...

Отзывы: