10
11
12
ASSEMBLY INSTRUCTIONS (DIRECT WIRE MOUNTING)
7b. Wire connection guide:
Ground wire:
•
For installation in the United States:
Wrap
ground wire from outlet box around ground
screw preassembled on mounting bracket (B)
no less than 2 in. from wire end. Tighten
ground screw. If fixture is supplied with a
ground wire, connect to outlet ground wire
with a wire connector (AA).
•
For installation in Canada:
If fixture is
supplied with ground wire, wrap ground wire
around ground screw on mounting bracket
(B). Tighten ground screw. Connect fixture
ground wire to outlet ground wire with the
wire connector (AA).
Supply wires:
• Connect the Neutral (White) supply wire from
the outlet box to the Neutral fixture wire
(Parallel Cord “D” shaped and ribbed).
• Connect the Hot (Black) supply wire from the
outlet box to the Hot fixture wire (Parallel
Cord round and smooth).
8b. Pass canopy (A) over the long knob
screws (HH) protruding from the
mounting bracket (B) and secure in place
with lock washers (DD) and threaded
knobs (CC).
NOTE:
Make sure all wires are inside of
canopy (A) and do not get pinched
between canopy (A) and mounting
bracket (B), or canopy (A) and wall.
NOTE:
Fixture should be mounted with
shade (D) in the down position as shown.
NOTE:
Ideally, edge of outlet box should
be flush with mounting surface. However,
many outlet boxes are recessed into the
surface. The long knob screws (HH) are
designed to have extra length to
accommodate various outlet box depths.
Go to Step 1c on Pg. 12
7b
BARE COPPER,
OR GREEN
GROUND
SUPPLY WIRE
BARE COPPER,
OR GREEN
GROUND
FIXTURE
WIRE
BLACK SUPPLY
WIRE
PARALLEL
FIXTURE CORD
(ROUND AND
SMOOTH)
PARALLEL FIXTURE
CORD (“D” SHAPED
AND RIDGED)
WHITE SUPPLY
WIRE
AA
Hardware Used
x 3
Wire Connector
AA
Hardware Used
x 2
Lock Washer
DD
x 2
Threaded Knobs
CC
8b
DD
CC
B
A
HH
D