Assembly Instructions

WireWorks

®

Tech Panel

KI

1330 Bellevue Street

P.O. Box 8100

Green Bay, Wisconsin  54308-8100

TEL (800) 424-2432

FAX (920) 468-0280

July, 2004

Tools Required:

3

16

” Allen Wrench

Definition

A WireWorks Tech Panel differs from a
standard WireWorks panel as follows:

1. Tech Panels do not utilize base

raceways on one or both sides 
of panel.

2. Tech Panel bottom tiles extend down

an additional 6" in lieu of 
the base raceway.

3. Tech Panels utilize plastic 

horizontal light blocks instead of
steel horizontal rails wherever 
possible. 

Figure 1.

Installing Tech Panels

1. Panel frame of tech panel assembles

in the same manner as standard
WireWorks panel.

Note:

Every Tech Panel has steel

horizontals at top and bottom. Refer
to installation drawing to locate
middle rails.

2. Install plastic light blocks where

specified on installation drawing.

Figure 2

.

Push tab on light block with finger,
no tools required, in towards pocket
of vertical post and seat both tabs
into the pockets (in which the top
rivet of the steel horizontal would
normally be located).

Note:

Light blocks 42” and greater

require the installation of clips.

Figure 1

Figure 2

tile hook

plastic light blocks

clip

(to be installed on light
blocks 42" and greater)

plastic light block for
on-module overhead
storage, or

steel horizontal rail for
off-module.

plastic light block where
there isn’t power at belt
height, or

steel horizontal rail for

power at belt height.