background image

EN

5

Operation Instructions

Cleaning & Maintenance

A) Installation Method

After taking out the product, firstly remove Water Pump Rod Stopper as shown in Fig. 1, then slide 

the Water Pump Slider to the bottom as shown in Fig. 2, so that the pump rod extends down into the 

tank and allows normal operation.

B) Function Buttons

Note: 

The buzzer beeps twice when the power is first turned on, and the unit enters the standby state    

(power on sound: BiBi, button pressing sound: Bi, power off sound: Bi--). All buttons except On/Off   

 are invalid.

1. 

On/Off button

     In standby mode, all buttons except On/Off are invalid. Press the On/Off to turn on the unit, and  

     the circuit enters working state. The initial wind speed of the unit is medium by default. The 

     corresponding normal mode LED turns on, no timing, wind direction and cool / humidify

     functions are available.

     In power on state, press this button, and the unit will turn off and enter standby mode. Press  

     this button again, and the unit will resume last wind speed. If the wind speed before shutdown 

     is low or silent, it starts from the medium level and switches to low or silent level after 3 

     seconds. If the wind speed before shutdown is medium or high, it enters medium or high level 

     directly. The natural mode and sleep mode won’t be saved. In this case, the unit enters normal 

     mode by default, and the swing function, timer and humidify function are saved.

2. Do not clean the appliance with metal scouring pads as it may scratch the surface or cause

    electrical shock.

3. Empty the water tank to avoid odour when not using the appliance.

4. If the product won’t be used for long period of time, remove the water tank, drain the water, and  

    then install the unit properly. Turn on air dry function, fully dry Honeycomb Filter, unplug the 

    power cord, pack the unit properly to prevent dust, and place in a dry and ventilated place.

Then slide the 

Water Pump Slider 

to the bottom

Remove Water 

Pump Rod 

Stopper

(Fig.1)

(Fig.2)

Содержание EAC20

Страница 1: ...ortant Mustahak Please read this manual carefully before operating this product Keep this manual handy for further reference Sila baca buku panduan ini dengan teliti sebelum menggunakan produk ini Sim...

Страница 2: ...ckle Left Shell Remote Control Receiver Water Level Display Window Reel Picture is for illustration purpose only Top Panel Cover Rear Casters Right Shell Water Pump Rod Stopper Horizontal Louver Remot...

Страница 3: ...rty dusty or polluted environments 4 Insert the plug to the AC mains securely Do not remove power plug by pulling through its cord Do not operate with wet hands or when the plug is wet 5 Do not fill w...

Страница 4: ...flux 16 Do not install this appliance in locations containing inflammable or explosive gases and sprays Do not expose it directly to sunlight for a long period of time 17 Do not insert fingers wooden...

Страница 5: ...button and the unit will turn off and enter standby mode Press this button again and the unit will resume last wind speed If the wind speed before shutdown is low or silent it starts from the medium...

Страница 6: ...s T 90s T 90s stop stop Natural mode in medium speed Natural mode in low speed 2 Wind speed button The wind speed can be converted in the following sequence Silent low medium high silent and circulate...

Страница 7: ...ore packing the unit Press and hold Speed button on the panel for 3 seconds to turn on the air dry function When the air dry function is turned on the wind speed jumps from the current speed level to...

Страница 8: ...ider to the tank bottom Slide Water Pump Slider again to raise the pump rod to the top Loosen Water Tank Buckle on both sides A Water filling 1 You need to add water to the tank if the cool humidify f...

Страница 9: ...dry function to dry the unit and the honeycomb filter then pull out the plug Loosen the Water Tank Buckle slide the Water Pump Slider to move the pump rod to the top and insert the Water Pump Rod Sto...

Страница 10: ...CN 10 1 7 13 14 16 15 5 6 3 9 2 8 4 10 17 11 18 12 19 20 21 A B 1 13 14 15 16 2 3 4 5 6 7 8 9 10 17 18 19 20 11 12 21...

Страница 11: ...CN 11 C x x x x 1 2 18 C to 45 C 45 C 3 4 5 6 MIN 7 8 9 10 11 Khind Mistral M Sdn Bhd EAC20 220 240V 50Hz 110W 20 480 1260rpm 9 17m min 323CFM 2000 8 390 x 342 x 897 3...

Страница 12: ...CN 12 12 13 14 15 16 17 18 19 i ii iii 1 a b c 2 3 4...

Страница 13: ...CN 13 A 1 2 B 1 1 2 2 3 3 1 2...

Страница 14: ...CN 14 4 4 5 5 1 2 4 8 1 2 6 6 1 2 6 6 6 12 12 12 18 21 33 45 48 54 69 72 78 84 24 30 33 39 43 51 57 63 69 72 78 84 18 21 27 39 45 51 57 63 69 72 84 T 90 T 90 T 90 3 30 30 30 30...

Страница 15: ...CN 15 C 1 60 2 50 5 10 3 4 3 20 0 5 20 20 20 5 i 30 ii 30 ON 6 15 A A 1 1 2 1 2...

Страница 16: ...CN 16 5 2 3 4 3 5 i MAX ii iii 3 4...

Страница 17: ...CN 17 7 8 6 B B 6 7 C C 1 1 3V CR2032 2 CR2032 8...

Страница 18: ...angka Kiri Penerima Pancaran Alat Kawalan Jauh Tingkap Paparan Paras Air Gelendung Pelindung Panel Atas Roda Belakang Kerangka Kanan Penghalang Rod Pam Air Daun Tetingkap Melintang Alat Kawalan Jauh G...

Страница 19: ...Suhu bilik 18 C hingga 45 C Suhu air pengisian semula 45 C 3 Jangan operasikan perkakas ini di dalam keadaan persekitaran kotor atau tercemar 4 Masukkan plag AC dengan sebaiknya Jangan keluarkan plag...

Страница 20: ...a perkakas 15 Jangan sandarkan perkakas ini pada dinding atau langsir atau objek lain yang mungkin menghalang aliran udara 16 Jangan memasang perkakas ini di lokasi yang mengandungi gas gas mudah terb...

Страница 21: ...tidak menggunakan perkakas ini 4 Sekiranya perkakas tidak digunakan untuk tempoh yang lama tanggalkan tangki air buangkan air di dalamnya dan kemudian pasang semula dengan kemas Hidupkan fungsi udara...

Страница 22: ...kalkan 2 Butang kelajuan Angin kelajuan angin boleh diubah mengikut aturan kitaran seperti berikut Senyap rendah Pertengahan Tinggi Senyap secara berkitaran LED akan menyala untuk menunjuk kedudukan m...

Страница 23: ...ngsi Perlindungan Paras Air Apabila fungsi sejuk diaktifkan pam air akan berkerja selama 50 saat Jika dalam tempoh ini kekurangan air dikesan pam akan berhenti beroperasi dan penggera akan berbunyi se...

Страница 24: ...a akan berbunyi beep 10 kali selepas bekalan kuasa kembali pulih Selepas 30 saat unit akan kembali beroperasi mengikut tetapan sebelumnya ii Jika anda menekan butan ON semula dalam tempoh saat tersebu...

Страница 25: ...ras air terletak di sebelah hadapan perkakas Gambarajah 5 1 Jangan masukkan air melebihi paras maksimum 2 Pastikan air yang digunakan adalah bersih 3 Tip Jika terdapat sedikit bauan pada perkakas atau...

Страница 26: ...Penerima Pancaran yang terletak pada unit Jika voltan bateri berkurangan sila buka penutupnya seperti ditunjukkan pada gambarajah 8 dan gantikan dengan bateri CR2032 yang baru Pastikan polar positif d...

Страница 27: ......

Страница 28: ...www khind com my...